PURPOSE: To compare the effectiveness and reproducibility of a new black-blood sequence vs. a conventional bright-blood gradient-echo T2* sequence for myocardial iron overload measurement in thalassemia. MATERIALS AND METHODS: Twenty thalassemia patients were studied. Black-blood sequence images were acquired in diastole after a double inversion recovery (DIR) preparation pulse. Bright-blood sequence images were acquired in both early systole and late diastole. The data were randomized and the T2* analysis was performed blindly by two independent observers. RESULTS: The T2* values from the black-blood sequence were comparable to those of the conventional bright-blood sequence (25.7 +/- 12.9 msec vs. 26.4 +/- 14.2 msec in early systole, P = 0.44; and 25.2 +/- 13.1 msec in late diastole, P = 0.41). The coefficient of variation (CV) for black-blood image T2* analysis was 4.1% compared with 8.9% (early systole P = 0.03) and 7.8% (late diastole P = 0.05) for bright-blood image analysis. CONCLUSION: The black-blood T2* technique yields high-contrast myocardial images, provides clearly depicted myocardial borders, and avoids blood signal contamination of the myocardium while yielding improvements in interobserver variability. (c) 2007 Wiley-Liss, Inc.
PURPOSE: To compare the effectiveness and reproducibility of a new black-blood sequence vs. a conventional bright-blood gradient-echo T2* sequence for myocardial iron overload measurement in thalassemia. MATERIALS AND METHODS: Twenty thalassemiapatients were studied. Black-blood sequence images were acquired in diastole after a double inversion recovery (DIR) preparation pulse. Bright-blood sequence images were acquired in both early systole and late diastole. The data were randomized and the T2* analysis was performed blindly by two independent observers. RESULTS: The T2* values from the black-blood sequence were comparable to those of the conventional bright-blood sequence (25.7 +/- 12.9 msec vs. 26.4 +/- 14.2 msec in early systole, P = 0.44; and 25.2 +/- 13.1 msec in late diastole, P = 0.41). The coefficient of variation (CV) for black-blood image T2* analysis was 4.1% compared with 8.9% (early systole P = 0.03) and 7.8% (late diastole P = 0.05) for bright-blood image analysis. CONCLUSION: The black-blood T2* technique yields high-contrast myocardial images, provides clearly depicted myocardial borders, and avoids blood signal contamination of the myocardium while yielding improvements in interobserver variability. (c) 2007 Wiley-Liss, Inc.
Authors: Sebastian Weingärtner; Nadja M Meßner; Frank G Zöllner; Mehmet Akçakaya; Lothar R Schad Journal: Magn Reson Med Date: 2016-09-16 Impact factor: 4.668
Authors: Taigang He; Peter D Gatehouse; Gillian C Smith; Raad H Mohiaddin; Dudley J Pennell; David N Firmin Journal: Magn Reson Med Date: 2008-11 Impact factor: 4.668
Authors: Hua Guo; Wing-Yan Au; Jerry S Cheung; Daniel Kim; Jens H Jensen; Pek-Lan Khong; Queenie Chan; Kevin C Chan; Christina Tosti; Haiying Tang; Truman R Brown; Wynnie W M Lam; Shau-Yin Ha; Gary M Brittenham; Ed X Wu Journal: J Magn Reson Imaging Date: 2009-08 Impact factor: 4.813
Authors: Jeanette Schulz-Menger; David A Bluemke; Jens Bremerich; Scott D Flamm; Mark A Fogel; Matthias G Friedrich; Raymond J Kim; Florian von Knobelsdorff-Brenkenhoff; Christopher M Kramer; Dudley J Pennell; Sven Plein; Eike Nagel Journal: J Cardiovasc Magn Reson Date: 2013-05-01 Impact factor: 5.364