Literature DB >> 17513901

Integration of Enhanced Optical Tracking Techniques and Imaging in IGRT.

Guido Baroni1, Marco Riboldi, Maria Francesca Spadea, Barbara Tagaste, Cristina Garibaldi, Roberto Orecchia, Antonio Pedotti.   

Abstract

In external beam radiotherapy, modern technologies for dynamic dose delivery and beam conformation provide high selectivity in radiation dose administration to the pathological volume. A comparable accuracy level is needed in the 3-D localization of tumor and organs at risk (OARs), in order to accomplish the planned dose distribution in the reality of each irradiation session. In-room imaging techniques for patient setup verification and tumor targeting may benefit of the combined daily use of optical tracking technologies, supported by techniques for the detection and compensation of organ motion events. Multiple solutions to enhance the use of optical tracking for the on-line correction of target localization uncertainties are described, with specific emphasis on the compensation of setup errors, breathing movements and non-rigid deformations. The final goal is the implementation of customized protocols where appropriate external landmarks, to be tracked in real-time by means of non-invasive optical devices, are selected as a function of inner target localization. The presented methodology features high accuracy in patient setup optimization, also providing a valuable tool for on-line patient surveillance, taking into account both breathing and deformation effects. The methodic application of optical tracking is put forward to represent a reliable and low cost procedure for the reduction of safety margins, once the patient-specific correlation between external landmarks and inner structures has been established. Therefore, the integration of optical tracking with in-room imaging devices is proposed as a way to gain higher confidence in the framework of Image Guided Radiation Therapy (IGRT) treatments.

Entities:  

Mesh:

Year:  2007        PMID: 17513901     DOI: 10.1269/jrr.48.a61

Source DB:  PubMed          Journal:  J Radiat Res        ISSN: 0449-3060            Impact factor:   2.724


  10 in total

1.  Accuracy of surface registration compared to conventional volumetric registration in patient positioning for head-and-neck radiotherapy: a simulation study using patient data.

Authors:  Youngjun Kim; Ruijiang Li; Yong Hum Na; Rena Lee; Lei Xing
Journal:  Med Phys       Date:  2014-12       Impact factor: 4.071

2.  Quantitative prediction of respiratory tidal volume based on the external torso volume change: a potential volumetric surrogate.

Authors:  Guang Li; Naveen C Arora; Huchen Xie; Holly Ning; Wei Lu; Daniel Low; Deborah Citrin; Aradhana Kaushal; Leor Zach; Kevin Camphausen; Robert W Miller
Journal:  Phys Med Biol       Date:  2009-03-05       Impact factor: 3.609

3.  Tumor motion tracking based on a four-dimensional computed tomography respiratory motion model driven by an ultrasound tracking technique.

Authors:  Lai-Lei Ting; Ho-Chiao Chuang; Ai-Ho Liao; Chia-Chun Kuo; Hsiao-Wei Yu; Hsin-Chuan Tsai; Der-Chi Tien; Shiu-Chen Jeng; Jeng-Fong Chiou
Journal:  Quant Imaging Med Surg       Date:  2020-01

4.  Quantification of an external motion surrogate for quality assurance in lung cancer radiation therapy.

Authors:  Jens Wölfelschneider; Tobias Brandt; Sebastian Lettmaier; Rainer Fietkau; Christoph Bert
Journal:  Biomed Res Int       Date:  2014-11-30       Impact factor: 3.411

Review 5.  Image-guided radiation therapy in lymphoma management.

Authors:  Tony Eng; Chul S Ha
Journal:  Radiat Oncol J       Date:  2015-09-30

6.  Development of a real-time internal and external marker tracking system for particle therapy: a phantom study using patient tumor trajectory data.

Authors:  Junsang Cho; Wonjoong Cheon; Sanghee Ahn; Hyunuk Jung; Heesoon Sheen; Hee Chul Park; Youngyih Han
Journal:  J Radiat Res       Date:  2017-09-01       Impact factor: 2.724

7.  An image-based method to synchronize cone-beam CT and optical surface tracking.

Authors:  Aurora Fassi; Joël Schaerer; Marco Riboldi; David Sarrut; Guido Baroni
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

8.  Reproducibility of the external surface position in left-breast DIBH radiotherapy with spirometer-based monitoring.

Authors:  Aurora Fassi; Giovanni B Ivaldi; Ilaria Meaglia; Patrizia Porcu; Paola Tabarelli de Fatis; Marco Liotta; Marco Riboldi; Guido Baroni
Journal:  J Appl Clin Med Phys       Date:  2014-01-04       Impact factor: 2.102

9.  Internal Motion Estimation by Internal-external Motion Modeling for Lung Cancer Radiotherapy.

Authors:  Haibin Chen; Zichun Zhong; Yiwei Yang; Jiawei Chen; Linghong Zhou; Xin Zhen; Xuejun Gu
Journal:  Sci Rep       Date:  2018-02-27       Impact factor: 4.379

10.  A step towards international prospective trials in carbon ion radiotherapy: investigation of factors influencing dose distribution in the facilities in operation based on a case of skull base chordoma.

Authors:  G Vogin; A Wambersie; M Koto; T Ohno; M Uhl; P Fossati; J Balosso
Journal:  Radiat Oncol       Date:  2019-02-01       Impact factor: 3.481

  10 in total