Literature DB >> 17505080

Fast laser scanning optical-CT apparatus for 3D radiation dosimetry.

Nikola Krstajić1, Simon J Doran.   

Abstract

Optical computed tomography (optical-CT) of 3D radiation dosimeters is a promising avenue for delivering an economic and reliable quality control of radiotherapy treatments such as intensity modulated radiotherapy, brachytherapy and stereotactic radiosurgery. The main problems in transferring 3D dosimeters to clinical setting have been in (1) the complexity of manufacture and behaviour of 3D dosimeters and (2) time-consuming readout and analysis of 3D dosimeters. This paper addresses the readout problem by showing that fast (20 min tomography scan), precise (projection absorbance signal-to-noise ratio is greater than 100:1 across the absorbance range 0.2 to 1.5) and accurate (good linearity in the calibration curve) measurements are possible using a novel method of optically scanning a laser beam across the 3D dosimeter.

Mesh:

Year:  2007        PMID: 17505080     DOI: 10.1088/0031-9155/52/11/N01

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Fast, high-resolution 3D dosimetry utilizing a novel optical-CT scanner incorporating tertiary telecentric collimation.

Authors:  H S Sakhalkar; M Oldham
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

2.  Comprehensive quality assurance for base of skull IMRT.

Authors:  A Thomas; J O'Daniel; J Adamovics; G Ibbott; M Oldham
Journal:  J Phys Conf Ser       Date:  2013

3.  A method to correct for spectral artifacts in optical-CT dosimetry.

Authors:  Andrew Thomas; Michael Pierquet; Kevin Jordan; Mark Oldham
Journal:  Phys Med Biol       Date:  2011-05-13       Impact factor: 3.609

Review 4.  Polymer gel dosimetry.

Authors:  C Baldock; Y De Deene; S Doran; G Ibbott; A Jirasek; M Lepage; K B McAuley; M Oldham; L J Schreiner
Journal:  Phys Med Biol       Date:  2010-02-11       Impact factor: 3.609

5.  The effect of motion on IMRT - looking at interplay with 3D measurements.

Authors:  A Thomas; H Yan; M Oldham; T Juang; J Adamovics; F F Yin
Journal:  J Phys Conf Ser       Date:  2013

Review 6.  Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

Authors:  Yves De Deene
Journal:  Gels       Date:  2022-09-19

7.  Effect of composition interactions on the dose response of an N-isopropylacrylamide gel dosimeter.

Authors:  Yuan-Jen Chang; Bor-Tsung Hsieh
Journal:  PLoS One       Date:  2012-10-12       Impact factor: 3.240

  7 in total