Literature DB >> 17500468

An intercomparison between film dosimetry and diode matrix for IMRT quality assurance.

F Banci Buonamici1, A Compagnucci, L Marrazzo, S Russo, M Bucciolini.   

Abstract

The evaluation of the agreement between measured and calculated dose plays an essential role in the quality assurance (QA) procedures for intensity modulated radiation therapy (IMRT). Film dosimetry has been widely adopted for this purpose due to excellent film characteristics in terms of spatial resolution; unfortunately, it is a time-consuming procedure and requires great care if film has to be used as an absolute dosimeter. If this is not the case, then an independent ionimetric measurement is mandatory to assess the absolute dose agreement. Arrays of detectors are now replacing films for routine IMRT QA, since they permit very simple verification procedures. They show excellent characteristics in terms of linearity, repeatability, and independence of the response from the dose rate, but at the same time present a poor spatial resolution, due to the limited number of detectors available. In our institution, a diode matrix (MapCHECK, provided by Sun Nuclear) is adopted for routine QA. The aim of this work is to compare the performances of absolute film dosimetry with this matrix in QA procedures and to investigate the origin of possible discrepancies between the two methods. The results we present show a very good agreement between the two detectors when used to assess the mean dose deviation between calculated and measured doses (in both cases 0.2%). If the y matrix method is adopted, MapCHECK response shows a slightly better agreement with computed dose distribution than film dosimetry (mean percentage of points satisfying the constraint y < or = 1: 96% versus 94%). This difference is shown not to depend on the different field sampling, but on the detectors' capabilities. Moreover, we show that the diode matrix is able to identify eventual delivery errors as well as film. Our conclusion is that the diode matrix may effectively replace both film dosimetry and ionimetric measurements in routine IMRT QA.

Mesh:

Year:  2007        PMID: 17500468     DOI: 10.1118/1.2713426

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  19 in total

1.  Advantage of 3D volumetric dosemeter in delivery quality assurance of dynamic arc therapy: comparison of pencil beam and Monte Carlo calculations.

Authors:  H-J Shin; J H Song; J-Y Jung; Y-K Kwak; C S Kay; Y-N Kang; B O Choi; H S Jang; S H Son
Journal:  Br J Radiol       Date:  2013-11-14       Impact factor: 3.039

2.  Clinical experience with machine log file software for volumetric-modulated arc therapy techniques.

Authors:  Luis Alberto Vazquez-Quino; Claudia Ivette Huerta-Hernandez; Dharanipathy Rangaraj
Journal:  Proc (Bayl Univ Med Cent)       Date:  2017-07

3.  Implementation and validation of a commercial portal dosimetry software for intensity-modulated radiation therapy pre-treatment verification.

Authors:  C Varatharaj; Eugenia Moretti; M Ravikumar; Maria Rosa Malisan; Sanjay S Supe; Renato Padovani
Journal:  J Med Phys       Date:  2010-10

4.  Evaluation of PTW Seven29 for tomotherapy patient-specific quality assurance and comparison with ScandiDos Delta(4).

Authors:  Pamela Myers; Sotirios Stathakis; Alonso N Gutiérrez; Carlos Esquivel; Panayiotis Mavroidis; Niko Papanikolaou
Journal:  J Med Phys       Date:  2012-04

5.  Impact of dose rate on accuracy of intensity modulated radiation therapy plan delivery using the pretreatment portal dosimetry quality assurance and setting up the workflow at hospital levels.

Authors:  Karunakaran Kaviarasu; N Arunai Nambi Raj; K Krishna Murthy; A Ananda Giri Babu; Bhaskar Laxman Durga Prasad
Journal:  J Med Phys       Date:  2015 Oct-Dec

6.  Comparison of four commercial devices for RapidArc and sliding window IMRT QA.

Authors:  Varatharaj Chandraraj; Sotirios Stathakis; Ravikumar Manickam; Carlos Esquivel; Sanjay S Supe; Nikos Papanikolaou
Journal:  J Appl Clin Med Phys       Date:  2011-04-04       Impact factor: 2.102

7.  Absolute dose verification of static intensity modulated radiation therapy (IMRT) with ion chambers of various volumes and TLD detectors.

Authors:  Hediye Acun-Bucht; Ebru Tuncay; Emin Darendeliler; Gönül Kemikler
Journal:  Rep Pract Oncol Radiother       Date:  2018-05-19

8.  Evaluation of a software system for estimating planned dose error in patients, based on planar IMRT QA measurements.

Authors:  Mohammad Bakhtiari; Ashkan Parniani; Fritz Lerma; Shannon Reynolds; James Jordan; Alireza Sedaghat; Mehrdad Sarfaraz; James Rodgers
Journal:  Radiol Oncol       Date:  2014-01-22       Impact factor: 2.991

9.  A Comprehensive Evaluation of NIPAM Polymer Gel Dosimeters on Three Orthogonal Planes and Temporal Stability Analysis.

Authors:  Kai-Yuan Cheng; Ling-Ling Hsieh; Cheng-Ting Shih
Journal:  PLoS One       Date:  2016-05-18       Impact factor: 3.240

10.  Establishing action levels for EPID-based QA for IMRT.

Authors:  Rebecca M Howell; Iris P N Smith; Christie S Jarrio
Journal:  J Appl Clin Med Phys       Date:  2008-06-23       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.