Influence of z overscanning on normalized effective doses calculated for pediatric patients undergoing multidetector CT examinations.

Antonis Tzedakis1, John Damilakis, Kostas Perisinakis, Apostolos Karantanas, Spiros Karabekios, Nicholas Gourtsoyiannis.   

Abstract

The purpose of this study was to evaluate the effect of z overscanning on normalized effective dose for pediatric patients undergoing multidetector-computed tomography (CT) examinations. Five commercially available mathematical anthropomorphic phantoms representing newborn, 1-, 5-, 10-, and 15-year-old patients and the Monte Carlo N-Particle (MCNP, version 4C2) radiation transport code were employed in the current study to simulate pediatric CT exposures. For all phantoms, axial and helical examinations at 120 kV tube voltage were simulated. Scans performed at 80 kV were also simulated. Sex-specific normalized effective doses were estimated for four standard CT examinations i.e., head-neck, chest, abdomen-pelvis, and trunk, for all pediatric phantoms. Data for both axial and helical mode acquisition were obtained. In the helical mode, z overscanning was taken into account. The validity of the Monte Carlo results was verified by comparison with dose data obtained using thermoluminescence dosimetry and a physical pediatric anthropomorphic phantom simulating a 10-year-old child. In all cases normalized effective dose values were found to increase with increasing z overscanning. The percentage differences in normalized data between axial and helical scans may reach 43%, 70%, 36%, and 26% for head-neck, chest, abdomen-pelvis, and trunk studies, respectively. Normalized data for female pediatric patients was in general higher compared to male patients for all ages, examined regions, and z overscanning values. For both male and female children, the normalized effective dose values were reduced as the age was increased. For the same typical exposure conditions, dose values decreased when lower tube voltage was used; for a 1-year-old child, for example, the effective dose was 3.8 times lower when 80 kV instead of 120 kV was used. Normalized data for the estimation of effective dose to pediatric patients undergoing standard axial and helical CT examinations on an multidetector CT system were calculated. This data was found to depend strongly on CT acquisition mode and exposure parameters as well as patient age and sex. The effective dose from a pediatric CT scan performed in axial mode was always considerably lower compared to the corresponding scan performed in helical mode, due to the additional tissue regions exposed to the primary beam in helical examinations as a result of z overscanning.

Entities:  

Mesh:

Year:  2007        PMID: 17500447     DOI: 10.1118/1.2710331

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  13 in total

1.  Reduction of the unnecessary dose from the over-range area with a spiral dynamic z-collimator: comparison of beam pitch and detector coverage with 128-detector row CT.

Authors:  Takashi Shirasaka; Yoshinori Funama; Mutsukazu Hayashi; Shinichi Awamoto; Masatoshi Kondo; Yasuhiko Nakamura; Masamitsu Hatakenaka; Hiroshi Honda
Journal:  Radiol Phys Technol       Date:  2011-10-15

2.  The effect of iodine uptake on radiation dose absorbed by patient tissues in contrast enhanced CT imaging: Implications for CT dosimetry.

Authors:  Kostas Perisinakis; Antonis Tzedakis; Kostas Spanakis; Antonios E Papadakis; Adam Hatzidakis; John Damilakis
Journal:  Eur Radiol       Date:  2017-07-14       Impact factor: 5.315

Review 3.  Management of auto exposure control during pediatric computed tomography.

Authors:  Dianna D Cody
Journal:  Pediatr Radiol       Date:  2014-10-11

4.  Radiation exposure during CT-guided biopsies: recent CT machines provide markedly lower doses.

Authors:  Nika Guberina; Michael Forsting; Adrian Ringelstein; Saravanabavaan Suntharalingam; Kai Nassenstein; Jens Theysohn; Axel Wetter
Journal:  Eur Radiol       Date:  2018-03-28       Impact factor: 5.315

5.  Evaluation of an adaptive detector collimation for prospectively ECG-triggered coronary CT angiography with third-generation dual-source CT.

Authors:  Michael Messerli; Patricia Dewes; Jan-Erik Scholtz; Christophe Arendt; Simon Wildermuth; Thomas J Vogl; Ralf W Bauer
Journal:  Eur Radiol       Date:  2017-12-07       Impact factor: 5.315

6.  Scan time and patient dose for thoracic imaging in neonates and small children using axial volumetric 320-detector row CT compared to helical 64-, 32-, and 16- detector row CT acquisitions.

Authors:  Lucia J M Kroft; Joost J H Roelofs; Jacob Geleijns
Journal:  Pediatr Radiol       Date:  2009-12-08

Review 7.  [Congenital abnormalities of the aorta in children and adolescents].

Authors:  J G Eichhorn; S Ley
Journal:  Radiologe       Date:  2007-11       Impact factor: 0.635

Review 8.  CT radiation dose optimization and estimation: an update for radiologists.

Authors:  Hyun Woo Goo
Journal:  Korean J Radiol       Date:  2011-12-23       Impact factor: 3.500

Review 9.  State-of-the-art CT imaging techniques for congenital heart disease.

Authors:  Hyun Woo Goo
Journal:  Korean J Radiol       Date:  2009-12-28       Impact factor: 3.500

Review 10.  Pushing CT and MR imaging to the molecular level for studying the "omics": current challenges and advancements.

Authors:  Hsuan-Ming Huang; Yi-Yu Shih
Journal:  Biomed Res Int       Date:  2014-03-13       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.