Literature DB >> 17499091

Bond strengths of one- and two-step self-etch adhesive systems.

Lisa A Knobloch1, David Gailey, Shereen Azer, William M Johnston, Nancy Clelland, Ronald E Kerby.   

Abstract

STATEMENT OF PROBLEM: One-bottle self-etching adhesives have been introduced that combine the etchant, primer, and adhesive into a single bottle in an effort to reduce the number of bonding steps. Limited research has been conducted comparing the efficacy of 1-bottle and 2-bottle self-etching adhesives.
PURPOSE: This investigation evaluated the microtensile bond strength (MTBS) of 3 one-step self-etching adhesives, 2 two-step self-etching adhesives, and a total-etch adhesive. A secondary objective was to evaluate the effect of an intermediary layer of elastic resin on the MTBS of 2 of the self-etching adhesives.
MATERIAL AND METHODS: The MTBS of 3 one-step self-etching adhesives (G-Bond, iBond, and Clearfil S(3)), 2 two-step self-etching adhesives (Clearfil SE and Optibond Solo Plus Self-Etch), and a total-etch adhesive (Prime & Bond NT) was evaluated. Microtensile bond strength (MPa) was determined using composite resin (Herculite XRV) cylinders bonded to the dentin surface of human third molars (n=24) using 6 bonding agents. Each bonded tooth specimen was longitudinally sectioned to produce bar-shaped specimens with a square cross-sectional nominal bond area of 1.4 mm(2) (n=20). Bonded specimens were stored in distilled water at 37 degrees C +/- 2 degrees C for 72 hours, during which time they were subjected to thermal cycling (1500 cycles, in water baths of 5 degrees C and 55 degrees C, for a dwell time of 30 seconds). Testing was performed on a universal testing machine at a crosshead speed of 1.0 mm/min. One-way ANOVA, Ryan-Einot-Gabriel-Welsh multiple range test, and Wald chi square test, each using an overall alpha=.05, were performed on all data. Low-power (x20) microscopic examination of the bond failure was observed for each specimen.
RESULTS: The 1-way ANOVA (P<.001) and Ryan-Einot-Gabriel-Welsh multiple range test (P<.05) showed significant differences between the mean MTBS values for several of the bonding agents tested. The Wald chi square test of the Weibull distribution showed significant differences between adhesives (P<.001).
CONCLUSION: Of the bonding agents tested, significantly higher MTBS was obtained with the total-etch 2-stage adhesive. The results of this study suggest that there are similar bond strengths between the 1- and 2-bottle self-etch adhesives.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17499091     DOI: 10.1016/j.prosdent.2007.02.013

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  9 in total

1.  Dentin infiltration ability of different classes of adhesive systems.

Authors:  Alina Langer; Nicoleta Ilie
Journal:  Clin Oral Investig       Date:  2012-02-29       Impact factor: 3.573

2.  Effect of Saliva on the Tensile Bond Strength of Different Generation Adhesive Systems: An In-Vitro Study.

Authors:  Nimisha Gupta; Abhay Mani Tripathi; Sonali Saha; Kavita Dhinsa; Aarti Garg
Journal:  J Clin Diagn Res       Date:  2015-07-01

3.  Evaluation of Shear Bond Strength of Feldspathic CAD/CAM Ceramic with Dentin using 2 Bonding Agents and 2 Surface Treatments- An Invitro Study.

Authors:  Ramesh Reddy Jetti; Muthukumar Balasubramaniam; Ahila Singaravel Chidambaranathan; Suganya Srinivasan
Journal:  J Clin Diagn Res       Date:  2015-11-01

4.  Effectiveness and biological compatibility of different generations of dentin adhesives.

Authors:  João M F da Silva; José R Rodrigues; Carlos H R Camargo; Virgilio Vilas Boas Fernandes; Karl-Anton Hiller; Helmut Schweikl; Gottfried Schmalz
Journal:  Clin Oral Investig       Date:  2013-05-28       Impact factor: 3.573

5.  Marginal seal stability of one bottle adhesives in Class V vs. Class I cavities.

Authors:  Juan R Mayoral; Ladislav Gregor; Edson A Campos; Miguel Roig; Ivo Krejci
Journal:  Clin Oral Investig       Date:  2010-01-05       Impact factor: 3.573

6.  Clinical effectiveness of a one-step self-etch adhesive in non-carious cervical lesions at 2 years.

Authors:  R Banu Ermis; Kirsten L Van Landuyt; Marcio Vivan Cardoso; Jan De Munck; Bart Van Meerbeek; Marleen Peumans
Journal:  Clin Oral Investig       Date:  2011-05-21       Impact factor: 3.573

7.  A retrospective multicenter study comparing metal-ceramic and composite single crowns performed in public general dentistry: 5-year results.

Authors:  Jennie Overmeer; Birger Narby; Lars Hjalmarsson; Kristina Arnrup; Alf Eliasson
Journal:  Acta Biomater Odontol Scand       Date:  2016-02-01

8.  Influence of voids in the hybrid layer based on self-etching adhesive systems: a 3-D FE analysis.

Authors:  Ana Paula Martini; Rodolfo Bruniera Anchieta; Eduardo Passos Rocha; Amilcar Chagas Freitas Junior; Erika Oliveira de Almeida; Renato Herman Sundfeld; Marco Antonio Luersen
Journal:  J Appl Oral Sci       Date:  2009       Impact factor: 2.698

9.  Effect of ferric sulfate contamination on the bonding effectiveness of etch-and-rinse and self-etch adhesives to superficial dentin.

Authors:  Shahram Farzin Ebrahimi; Niloofar Shadman; Arezoo Abrishami
Journal:  J Conserv Dent       Date:  2013-03
  9 in total