Literature DB >> 17494778

Is brachial artery peak velocity variation ready for prime time?

Matthias Eikermann, Sheldon Magder, Atul Malhotra.   

Abstract

Mesh:

Year:  2007        PMID: 17494778      PMCID: PMC2278172          DOI: 10.1378/chest.07-0304

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


× No keyword cloud information.
  17 in total

Review 1.  Clinical usefulness of respiratory variations in arterial pressure.

Authors:  Sheldon Magder
Journal:  Am J Respir Crit Care Med       Date:  2004-01-15       Impact factor: 21.405

2.  Intensive care physicians' insufficient knowledge of right-heart catheterization at the bedside: time to act?

Authors:  A Gnaegi; F Feihl; C Perret
Journal:  Crit Care Med       Date:  1997-02       Impact factor: 7.598

3.  Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock.

Authors:  M Feissel; F Michard; I Mangin; O Ruyer; J P Faller; J L Teboul
Journal:  Chest       Date:  2001-03       Impact factor: 9.410

4.  Reversed pulsus paradoxus.

Authors:  R A Massumi; D T Mason; Z Vera; R Zelis; J Otero; E A Amsterdam
Journal:  N Engl J Med       Date:  1973-12-13       Impact factor: 91.245

5.  The use of respiratory variations in right atrial pressure to predict the cardiac output response to PEEP.

Authors:  S Magder; D Lagonidis; F Erice
Journal:  J Crit Care       Date:  2001-09       Impact factor: 3.425

6.  Predicting fluid responsiveness in patients undergoing cardiac surgery: functional haemodynamic parameters including the Respiratory Systolic Variation Test and static preload indicators.

Authors:  S Preisman; S Kogan; H Berkenstadt; A Perel
Journal:  Br J Anaesth       Date:  2005-12       Impact factor: 9.166

7.  Transient analysis of cardiopulmonary interactions. I. Diastolic events.

Authors:  J Peters; M K Kindred; J L Robotham
Journal:  J Appl Physiol (1985)       Date:  1988-04

8.  Transient analysis of cardiopulmonary interactions. II. Systolic events.

Authors:  J Peters; M K Kindred; J L Robotham
Journal:  J Appl Physiol (1985)       Date:  1988-04

Review 9.  Why protect the right ventricle in patients with acute respiratory distress syndrome?

Authors:  Antoine Vieillard-Baron; François Jardin
Journal:  Curr Opin Crit Care       Date:  2003-02       Impact factor: 3.687

10.  Negative intrathoracic pressure decreases independently left ventricular filling and emptying.

Authors:  J Peters; C Fraser; R S Stuart; W Baumgartner; J L Robotham
Journal:  Am J Physiol       Date:  1989-07
View more
  1 in total

1.  Brachial artery peak velocity variation to predict fluid responsiveness in mechanically ventilated patients.

Authors:  Manuel Ignacio Monge García; Anselmo Gil Cano; Juan Carlos Díaz Monrové
Journal:  Crit Care       Date:  2009-09-03       Impact factor: 9.097

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.