Literature DB >> 9034253

Intensive care physicians' insufficient knowledge of right-heart catheterization at the bedside: time to act?

A Gnaegi1, F Feihl, C Perret.   

Abstract

OBJECTIVE: To evaluate French, Swiss, and Belgian intensive care physicians' knowledge about the pulmonary artery catheter.
DESIGN: Survey study by questionnaire.
SETTING: Eighty-six European university and nonuniversity intensive care units (ICUs).
SUBJECTS: One hundred thirty-four ICUs identified from the directories of two European intensive care medicine societies were asked to participate. Five hundred thirty-five critical care physicians working in 86 ICUs participated.
INTERVENTIONS: In any particular ICU, all physicians were to complete--simultaneously, anonymously and without prior notice--a multiple choice questionnaire consisting of 31 questions regarding all aspects of bedside pulmonary artery catheterization. This questionnaire was the same one already used and extensively validated in a similar study conducted several years earlier in the United States and Canada.
MEASUREMENTS AND MAIN RESULTS: The percentage of correct answers per participant (score) was tabulated. Sixty-eight percent of respondents still in training (n = 232) believed that their knowledge of the pulmonary artery catheter was less than adequate; 36% of those who had completed their postgraduate training (n = 294) also believed their knowledge to be inadequate. The mean score of all respondents was 72.2 +/- 14.4%, significantly lower (p <.0001) in case of uncompleted postgraduate training (67.3 +/- 14.7%, lower quartile 56.7%, median 70.0%, upper quartile 76.7%), as compared with completed postgraduate training (76.1 +/- 13.0%, lower quartile 70.0%, median 80.0%, upper quartile 86.7%). When using multivariate analysis, the location of the ICU in a university hospital, the belief of respondent that his/her knowledge of the pulmonary artery catheter was adequate, and the responsibility for supervising catheter insertion were the only independent predictors of good performance on the questionnaire (p < .001 for all three variables). It was impossible to identify any subcategory of physicians with a uniformly good knowledge of the pulmonary artery catheter. The proportion of incorrect answers to some basic items was disturbingly high. For instance, approximately 50% of the respondents, whether trained or in training, did not correctly identify pulmonary artery occlusion pressure from a clear chart recording.
CONCLUSIONS: Knowledge of right-heart pulmonary artery catheterization is not uniformly good among ICU physicians. Accreditation policies and teaching practices concerning this technique need urgent revision.

Entities:  

Mesh:

Year:  1997        PMID: 9034253     DOI: 10.1097/00003246-199702000-00003

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  35 in total

1.  Hemodynamic assessment: the technique or the physician at fault?

Authors:  Daniel De Backer
Journal:  Intensive Care Med       Date:  2003-11       Impact factor: 17.440

2.  Decision support and safety of clinical environments.

Authors:  A H Morris
Journal:  Qual Saf Health Care       Date:  2002-03

3.  A computer program for interpreting pulmonary artery catheterization data: results of the European HEMODYN Resident Study.

Authors:  Pierre Squara; Etienne Fourquet; Luc Jacquet; Alain Broccard; Thomas Uhlig; Andrew Rhodes; Jan Bakker; Claude Perret
Journal:  Intensive Care Med       Date:  2003-03-25       Impact factor: 17.440

4.  What's in a beat?

Authors:  Mervyn Singer
Journal:  Intensive Care Med       Date:  2003-10       Impact factor: 17.440

Review 5.  Is there a role for invasive hemodynamic monitoring in acute heart failure management?

Authors:  Daniel De Backer
Journal:  Curr Heart Fail Rep       Date:  2015-06

6.  Assessing pulmonary permeability by transpulmonary thermodilution allows differentiation of hydrostatic pulmonary edema from ALI/ARDS.

Authors:  Xavier Monnet; Nadia Anguel; David Osman; Olfa Hamzaoui; Christian Richard; Jean-Louis Teboul
Journal:  Intensive Care Med       Date:  2007-01-13       Impact factor: 17.440

7.  Is brachial artery peak velocity variation ready for prime time?

Authors:  Matthias Eikermann; Sheldon Magder; Atul Malhotra
Journal:  Chest       Date:  2007-05       Impact factor: 9.410

8.  Pilot study on the influence of liver blood flow and cardiac output on the clearance of propofol in critically ill patients.

Authors:  Mariska Y M Peeters; Leon P H J Aarts; Ferenc A Boom; Leo J Bras; Dick Tibboel; Meindert Danhof; Catherijne A J Knibbe
Journal:  Eur J Clin Pharmacol       Date:  2007-11-13       Impact factor: 2.953

Review 9.  Matching total body oxygen consumption and delivery: a crucial objective?

Authors:  Pierre Squara
Journal:  Intensive Care Med       Date:  2004-09-21       Impact factor: 17.440

10.  Continuous cardiac output and left atrial pressure monitoring by long time interval analysis of the pulmonary artery pressure waveform: proof of concept in dogs.

Authors:  Da Xu; N Bari Olivier; Ramakrishna Mukkamala
Journal:  J Appl Physiol (1985)       Date:  2008-12-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.