Literature DB >> 17483881

Effects of photo-induced graft polymerization of 2-methacryloyloxyethyl phosphorylcholine on physical properties of cross-linked polyethylene in artificial hip joints.

Masayuki Kyomoto1, Toru Moro, Tomohiro Konno, Hiroaki Takadama, Hiroshi Kawaguchi, Yoshio Takatori, Kozo Nakamura, Noboru Yamawaki, Kazuhiko Ishihara.   

Abstract

Osteolysis caused by wear particles from polyethylene in the artificial hip joints is a serious issue. We have used photo-induced radical graft polymerization to graft 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer onto the surface of cross-linked polyethylene (CLPE-g-MPC) in order to reduce friction and wear at the bearing surface of the joint. The physical and mechanical properties of CLPE and CLPE-g-MPC were not significantly different, expect that the friction coefficient of untreated CLPE cups was 0.0075, compared with 0.0009 for CLPE-g-MPC cup, an 88% reduction. After 3.0 x 10(6) cycles in the hip joint simulator test, we could not observe any wear of CLPE-g-MPC cups. We concluded that the advantage of photo-induced radical graft polymerization technique was that the grafted MPC polymer gave a high lubricity only on the surface and has no effect on the bulk properties of the CLPE substrate.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17483881     DOI: 10.1007/s10856-007-3063-0

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  21 in total

1.  Analysis of a phosphorylcholine-based polymer coating on a coronary stent pre- and post-implantation.

Authors:  A L Lewis; L A Tolhurst; P W Stratford
Journal:  Biomaterials       Date:  2002-04       Impact factor: 12.479

2.  Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements.

Authors:  H McKellop; F W Shen; B Lu; P Campbell; R Salovey
Journal:  J Orthop Res       Date:  1999-03       Impact factor: 3.494

3.  Wear of highly cross-linked polyethylene acetabular cup in Japan.

Authors:  Hironobu Oonishi; Sok Chol Kim; Yasuhiro Takao; Masayuki Kyomoto; Mikio Iwamoto; Masaru Ueno
Journal:  J Arthroplasty       Date:  2006-10       Impact factor: 4.757

4.  Reduced thrombogenicity of polymers having phospholipid polar groups.

Authors:  K Ishihara; R Aragaki; T Ueda; A Watenabe; N Nakabayashi
Journal:  J Biomed Mater Res       Date:  1990-08

5.  Early mobilization after protamine reversal of heparin following implantation of phosphorylcholine-coated stents in totally occluded coronary arteries.

Authors:  K K Kuiper; J E Nordrehaug
Journal:  Am J Cardiol       Date:  2000-03-15       Impact factor: 2.778

6.  Influence of proteoglycan contents and of tissue hydration on the frictional characteristics of articular cartilage.

Authors:  M H Naka; Y Morita; K Ikeuchi
Journal:  Proc Inst Mech Eng H       Date:  2005-05       Impact factor: 1.617

7.  Surface grafting of artificial joints with a biocompatible polymer for preventing periprosthetic osteolysis.

Authors:  Toru Moro; Yoshio Takatori; Kazuhiko Ishihara; Tomohiro Konno; Yorinobu Takigawa; Tomiharu Matsushita; Ung-Il Chung; Kozo Nakamura; Hiroshi Kawaguchi
Journal:  Nat Mater       Date:  2004-10-24       Impact factor: 43.841

8.  Acute and mid-term results of phosphorylcholine-coated stents in primary coronary stenting for acute myocardial infarction.

Authors:  M Galli; L Sommariva; F Prati; S Zerboni; A Politi; R Bonatti; S Mameli; E Butti; A Pagano; G Ferrari
Journal:  Catheter Cardiovasc Interv       Date:  2001-06       Impact factor: 2.692

9.  Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty.

Authors:  D H Sochart
Journal:  Clin Orthop Relat Res       Date:  1999-06       Impact factor: 4.176

10.  Clinical performance of a highly cross-linked polyethylene at two years in total hip arthroplasty: a randomized prospective trial.

Authors:  John M Martell; James J Verner; Stephen J Incavo
Journal:  J Arthroplasty       Date:  2003-10       Impact factor: 4.757

View more
  3 in total

1.  Multidirectional wear and impact-to-wear tests of phospholipid-polymer-grafted and vitamin E-blended crosslinked polyethylene: a pilot study.

Authors:  Masayuki Kyomoto; Toru Moro; Yoshio Takatori; Sakae Tanaka; Kazuhiko Ishihara
Journal:  Clin Orthop Relat Res       Date:  2015-03       Impact factor: 4.176

2.  Cartilage-mimicking, high-density brush structure improves wear resistance of crosslinked polyethylene: a pilot study.

Authors:  Masayuki Kyomoto; Toru Moro; Yoshio Takatori; Hiroshi Kawaguchi; Kazuhiko Ishihara
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

3.  Examination of 2-methacryloyloxyethyl phosphorylcholine polymer coated acrylic resin denture base material: surface characteristics and Candida albicans adhesion.

Authors:  İrem Türkcan; A Dilek Nalbant; Erhan Bat; Gülçin Akca
Journal:  J Mater Sci Mater Med       Date:  2018-07-03       Impact factor: 3.896

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.