Quality control in antimicrobial disk susceptibility testing: a Belgian multicenter study.

S Lauwers1, J Philippe, A Van Zeebroeck, D Pierard, M P Derde, L Kaufman.   

Abstract

A Belgian multicenter trial was conducted to evaluate problems encountered with quality control results of antimicrobial disk susceptibility testing and to compare the performance of BBL disks and Rosco tablets. Over a period of four weeks 18 laboratories daily tested three reference strains against eight antibiotics. A standardised method was used by all participants. For all results together 10.4% and 7.3% of the measurements with BBL disks and Rosco tablets, respectively, were outside the recommended range. Major problems were observed for some specific strain-antibiotic combinations. Standard deviations were similar for both systems; their precision was comparable. The results suggest that cooperation between manufacturers and some reference laboratories could be improved in order to establish optimal quality control limits.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1748119     DOI: 10.1007/bf01975819

Source DB:  PubMed          Journal:  Eur J Clin Microbiol Infect Dis        ISSN: 0934-9723            Impact factor:   3.267


  9 in total

1.  Stable antibiotic sensitivity disks.

Authors:  R R Pfeiffer; G L Engel; D Coleman
Journal:  Antimicrob Agents Chemother       Date:  1976-05       Impact factor: 5.191

2.  Selection of a reference lot of Mueller-Hinton agar.

Authors:  H M Pollock; A L Barry; T L Gavan; P C Fuchs; S Hansen; C L Thornsberry; H Frankel; S B Forsythe
Journal:  J Clin Microbiol       Date:  1986-07       Impact factor: 5.948

3.  Spurious oxacillin resistance in Staphylococcus aureus because of defective oxacillin disks.

Authors:  J M Boyce; J R Lonks; A A Medeiros; E F Papa; S Campbell
Journal:  J Clin Microbiol       Date:  1988-07       Impact factor: 5.948

4.  Interpretation of the disk diffusion susceptibility test for amikacin: report of a collaborative study.

Authors:  J A Washington; P K Yu; T L Gavan; F D Schoenknecht; C Thornsberry
Journal:  Antimicrob Agents Chemother       Date:  1979-03       Impact factor: 5.191

5.  Antibiotic susceptibility testing by a standardized single disk method.

Authors:  A W Bauer; W M Kirby; J C Sherris; M Turck
Journal:  Am J Clin Pathol       Date:  1966-04       Impact factor: 2.493

6.  Controversies in antimicrobial susceptibility testing.

Authors:  F G Witebsky
Journal:  Clin Lab Med       Date:  1984-03       Impact factor: 1.935

7.  Evaluation of Mueller-Hinton agar for disk diffusion susceptibility tests.

Authors:  P R Murray; J R Zeitinger
Journal:  J Clin Microbiol       Date:  1983-11       Impact factor: 5.948

8.  Error rates associated with the use of recently proposed breakpoints for testing Pseudomonas aeruginosa versus gentamicin, tobramycin, and amikacin by the standardized disk agar diffusion test.

Authors:  B F Woolfrey; J M Fox; C O Quall; R T Lally
Journal:  Antimicrob Agents Chemother       Date:  1983-11       Impact factor: 5.191

9.  Cation components of Mueller-Hinton agar affecting testing of Pseudomonas aeruginosa susceptibility to gentamicin.

Authors:  M A Kenny; H M Pollock; B H Minshew; E Casillas; F D Schoenknecht
Journal:  Antimicrob Agents Chemother       Date:  1980-01       Impact factor: 5.191

  9 in total
  1 in total

1.  Comparison of Rosco Neo-Sensitabs with Oxoid paper disks in EUCAST disk diffusion antimicrobial susceptibility testing on Mueller-Hinton agar.

Authors:  U S Justesen; Z Acar; K Olsson; T G Jensen; M B Kerrn; R L Skov; B Gahrn-Hansen
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2012-12-12       Impact factor: 3.267

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.