Literature DB >> 17473343

Performance analysis of steady-state harmonic elastography.

Marvin M Doyley1, Qing Feng, John B Weaver, Keith D Paulsen.   

Abstract

Shear modulus estimation can be confounded by the ill-posed nature of the inverse elasticity problem. In this paper, we report the results of experiments conducted on simulated and gelatin phantoms to investigate the effect of various parameters (i.e., regularization, spatial filtering and the subzone generation process) associated with shear modulus reconstruction on the statistical accuracy (mean squared error), and image quality (i.e., contrast and spatial resolution) of the recovered mechanical properties. The results indicate several interesting observations. Firstly, the intrinsic spatial resolution of magnetic resonance elastography (MRE) is dependent on both regularization and spatial filtering. Secondly, the elastographic contrast-to-noise ratio (CNR(e)) increases with increasing regularization and spatial filtering, but it was not affected by the zoning parameters (i.e., the subzones and the extent of the overlap). Thirdly, the statistical accuracy (MSE) of the recovered property improved with increasing regularization, and spatial filtering weight, but the size of the subdomains and their overlap had no significant effect.

Mesh:

Year:  2007        PMID: 17473343     DOI: 10.1088/0031-9155/52/10/002

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Effects of frequency- and direction-dependent elastic materials on linearly elastic MRE image reconstructions.

Authors:  I M Perreard; A J Pattison; M Doyley; M D J McGarry; Z Barani; E E Van Houten; J B Weaver; K D Paulsen
Journal:  Phys Med Biol       Date:  2010-10-28       Impact factor: 3.609

2.  Optimized motion estimation for MRE data with reduced motion encodes.

Authors:  Huifang Wang; John B Weaver; Marvin M Doyley; Francis E Kennedy; Keith D Paulsen
Journal:  Phys Med Biol       Date:  2008-04-03       Impact factor: 3.609

3.  Viscoelastic properties of soft gels: comparison of magnetic resonance elastography and dynamic shear testing in the shear wave regime.

Authors:  R J Okamoto; E H Clayton; P V Bayly
Journal:  Phys Med Biol       Date:  2011-09-09       Impact factor: 3.609

4.  Magnetic resonance poroelastography: an algorithm for estimating the mechanical properties of fluid-saturated soft tissues.

Authors:  Phillip R Perriñez; Francis E Kennedy; Elijah E W Van Houten; John B Weaver; Keith D Paulsen
Journal:  IEEE Trans Med Imaging       Date:  2010-03       Impact factor: 10.048

5.  Model-based elastography: a survey of approaches to the inverse elasticity problem.

Authors:  M M Doyley
Journal:  Phys Med Biol       Date:  2012-01-06       Impact factor: 3.609

Review 6.  Stiffness reconstruction methods for MR elastography.

Authors:  Daniel Fovargue; David Nordsletten; Ralph Sinkus
Journal:  NMR Biomed       Date:  2018-05-18       Impact factor: 4.044

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.