Literature DB >> 17463305

Hierarchy of individual calibration levels for heart rate and accelerometry to measure physical activity.

Søren Brage1, Ulf Ekelund, Niels Brage, Mark A Hennings, Karsten Froberg, Paul W Franks, Nicholas J Wareham.   

Abstract

Combining accelerometry with heart rate (HR) monitoring may improve precision of physical activity measurement. Considerable variation exists in the relationships between physical activity intensity (PAI) and HR and accelerometry, which may be reduced by individual calibration. However, individual calibration limits feasibility of these techniques in population studies, and less burdensome, yet valid, methods of calibration are required. We aimed to evaluate the precision of different individual calibration procedures against a reference calibration procedure: a ramped treadmill walking-running test with continuous measurement of PAI by indirect calorimetry in 26 women and 25 men [mean (SD): 35 (9) yr, 1.69 (0.10) m, 70 (14) kg]. Acceleration (along the longitudinal axis of the trunk) and HR were measured simultaneously. Alternative calibration procedures included treadmill testing without calorimetry, submaximal step and walk tests with and without calorimetry, and nonexercise calibration using sleeping HR and gender. Reference accelerometry and HR models explained >95% of the between-individual variance in PAI (P < 0.001). This fraction dropped to 73 and 81%, respectively, for accelerometry and HR models calibrated with treadmill tests without calorimetry. Step-test calibration captured 62-64% (accelerometry) and 68% (HR) of the variance between individuals. Corresponding values were 63-76% and 59-61% for walk-test calibration. There was only little benefit of including calorimetry during step and walk calibration for HR models. Nonexercise calibration procedures explained 54% (accelerometry) and 30% (HR) of the between-individual variance. In conclusion, a substantial proportion of the between-individual variance in relationships between PAI, accelerometry, and HR is captured with simple calibration procedures, feasible for use in epidemiological studies.

Entities:  

Mesh:

Year:  2007        PMID: 17463305     DOI: 10.1152/japplphysiol.00092.2006

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  134 in total

1.  A comparison of energy expenditure estimates from the Actiheart and Actical physical activity monitors during low intensity activities, walking, and jogging.

Authors:  David K Spierer; Marshall Hagins; Andrew Rundle; Evangelos Pappas
Journal:  Eur J Appl Physiol       Date:  2010-10-17       Impact factor: 3.078

2.  Light-intensity activities are important for estimating physical activity energy expenditure using uniaxial and triaxial accelerometers.

Authors:  Yosuke Yamada; Keiichi Yokoyama; Risa Noriyasu; Tomoaki Osaki; Tetsuji Adachi; Aya Itoi; Yoshihiko Naito; Taketoshi Morimoto; Misaka Kimura; Shingo Oda
Journal:  Eur J Appl Physiol       Date:  2008-10-14       Impact factor: 3.078

3.  Different methods for monitoring intensity during water-based aerobic exercises.

Authors:  C Raffaelli; C Galvani; M Lanza; Paola Zamparo
Journal:  Eur J Appl Physiol       Date:  2011-04-19       Impact factor: 3.078

Review 4.  Effects of continuous positive airway pressure on energy balance regulation: a systematic review.

Authors:  Ari Shechter
Journal:  Eur Respir J       Date:  2016-10-20       Impact factor: 16.671

5.  Accuracy of optimized branched algorithms to assess activity-specific physical activity energy expenditure.

Authors:  Andy G Edwards; James O Hill; William C Byrnes; Raymond C Browning
Journal:  Med Sci Sports Exerc       Date:  2010-04       Impact factor: 5.411

6.  Randomised controlled trial of the effects of physical activity feedback on awareness and behaviour in UK adults: the FAB study protocol [ISRCTN92551397].

Authors:  Clare Watkinson; Esther M F van Sluijs; Stephen Sutton; Theresa Marteau; Simon J Griffin
Journal:  BMC Public Health       Date:  2010-03-18       Impact factor: 3.295

7.  Commuting and health in Cambridge: a study of a 'natural experiment' in the provision of new transport infrastructure.

Authors:  David Ogilvie; Simon Griffin; Andy Jones; Roger Mackett; Cornelia Guell; Jenna Panter; Natalia Jones; Simon Cohn; Lin Yang; Cheryl Chapman
Journal:  BMC Public Health       Date:  2010-11-16       Impact factor: 3.295

8.  The influence of adjustment for energy misreporting on relations of cake and cookie intake with cardiometabolic disease risk factors.

Authors:  M Gottschald; S Knüppel; H Boeing; B Buijsse
Journal:  Eur J Clin Nutr       Date:  2016-07-27       Impact factor: 4.016

9.  Earbud-based sensor for the assessment of energy expenditure, HR, and VO2max.

Authors:  Steven Francis Leboeuf; Michael E Aumer; William E Kraus; Johanna L Johnson; Brian Duscha
Journal:  Med Sci Sports Exerc       Date:  2014       Impact factor: 5.411

10.  Randomized controlled trial of the efficacy of aerobic exercise in reducing metabolic risk in healthy older people: The Hertfordshire Physical Activity Trial.

Authors:  Francis M Finucane; Jessica Horton; Lisa R Purslow; David B Savage; Soren Brage; Hervé Besson; Kenneth Horton; Ema De Lucia Rolfe; Alison Sleigh; Stephen J Sharp; Helen J Martin; Avan Aihie Sayer; Cyrus Cooper; Ulf Ekelund; Simon J Griffin; Nicholas J Wareham
Journal:  BMC Endocr Disord       Date:  2009-06-19       Impact factor: 2.763

View more