Literature DB >> 17455832

Corneal radii and anterior chamber depth measurements using the IOLmaster versus the Pentacam.

Mirjam S Reuland1, Andreas J Reuland, Yutaro Nishi, Gerd U Auffarth.   

Abstract

PURPOSE: Corneal radii (R1, R2) and anterior chamber depth are important parameters for biometry and refractive surgery. This study aimed to investigate whether the IOLMaster, a biometric device, and the Pentacam, a rotating Scheimpflug camera, provide comparable results.
METHODS: In this prospective study, corneal radii and anterior chamber depth were analyzed in 82 eyes of 41 phakic patients (median age 72 years) using the IOLMaster and Pentacam. Normal distribution was confirmed using the Kolmogorov-Smirnov test. A paired t test was used for statistical analysis.
RESULTS: No statistically significant difference was noted for R2 using the Pentacam versus the IOLMaster (P = .40). There was a small statistical difference of 0.03 mm (P < .01) for R1 (corresponding to 0.08 diopters [D]). The IOLMaster measured a mean R1 of 7.87 mm and R2 of 7.67 mm. The Pentacam measured mean R1 of 7.90 mm and R2 of 7.69 mm. For anterior chamber depth values, a small statistically significant difference of 0.05 mm (P < .001) was found (corresponding to 0.01 D). Mean anterior chamber depth measured from the epithelium was 3.20 mm for the IOLMaster and 3.25 mm for the Pentacam. The Bland-Altman plot showed no distorting trends for either variable.
CONCLUSIONS: Keratometry and anterior chamber depth were comparable for the two devices. If the axial length is known, the Pentacam can be used as a biometric device.

Entities:  

Mesh:

Year:  2007        PMID: 17455832     DOI: 10.3928/1081-597X-20070401-09

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  10 in total

1.  Evaluation of the agreement between Pentacam and ultrasound biomicroscopy measurements of anterior chamber depth in Chinese patients with primary angle-closure glaucoma.

Authors:  Juan Liang; Wei Liu; Xiaoli Xing; Hua Liu; Shaozhen Zhao; Jian Ji
Journal:  Jpn J Ophthalmol       Date:  2010-08-11       Impact factor: 2.447

2.  Anterior chamber depth in normal subjects by rotating scheimpflug imaging.

Authors:  Matthew T Feng; Michael W Belin; Renato Ambrósio; Satinder P S Grewal; Wang Yan; Mohamed S Shaheen; Charles McGhee; Naoyuki Maeda; Tobias H Neuhann; H Burkhard Dick; Saleh A Alageel; Andreas Steinmueller
Journal:  Saudi J Ophthalmol       Date:  2011-04-30

3.  [Scheimpflug and topography systems in ophthalmologic diagnostics].

Authors:  G U Auffarth; A F M Borkenstein; A Ehmer; A Mannsfeld; T M Rabsilber; M P Holzer
Journal:  Ophthalmologe       Date:  2008-09       Impact factor: 1.059

Review 4.  Device interchangeability on anterior chamber depth and white-to-white measurements: a thorough literature review.

Authors:  Alberto Domínguez-Vicent; Cari Pérez-Vives; Teresa Ferrer-Blasco; Santiago García-Lázaro; Robert Montés-Micó
Journal:  Int J Ophthalmol       Date:  2016-07-18       Impact factor: 1.779

5.  Differences and Limits of Agreement among Pentacam, Corvis-ST, and IOL-Master 700 Optical Biometric Devices regarding Central Corneal Thickness Measurements.

Authors:  Sattar Rajabi; Amir Asharlous; Abbas Riazi; Mehdi Khabazkhoob; Alireza Moalej
Journal:  J Curr Ophthalmol       Date:  2022-04-16

6.  Comparison of Anterior Chamber Depth Measurements from the Galilei Dual Scheimpflug Analyzer with IOLMaster.

Authors:  Roma P Patel; Rahul T Pandit
Journal:  J Ophthalmol       Date:  2012-01-19       Impact factor: 1.909

7.  Comparison of corneal curvature and anterior chamber depth measurements using the manual keratometer, Lenstar LS 900 and the Pentacam.

Authors:  Omür Ö Uçakhan; Veysel Akbel; Zeynep Bıyıklı; Ayfer Kanpolat
Journal:  Middle East Afr J Ophthalmol       Date:  2013 Jul-Sep

8.  Comparison of optical low coherence interferometry and Scheimpflug imaging combined with partial coherence interferometry biometers in cataract eyes.

Authors:  Moonjung Kim; Eui S Han
Journal:  Saudi J Ophthalmol       Date:  2022-08-29

9.  Comparison of Anterior Segment Biometric Measurements between Pentacam HR and IOLMaster in Normal and High Myopic Eyes.

Authors:  Jing Dong; Maolong Tang; Yaqin Zhang; Yading Jia; Haining Zhang; Zhijie Jia; Xiaogang Wang
Journal:  PLoS One       Date:  2015-11-17       Impact factor: 3.240

10.  Accuracy of Corneal Power Measurements for Intraocular Lens Power Calculation after Myopic Laser In situ Keratomileusis.

Authors:  Hany A Helaly; Mohammad A M El-Hifnawy; Mohamed Shafik Shaheen; Amr F Abou El-Kheir
Journal:  Middle East Afr J Ophthalmol       Date:  2016 Jan-Mar
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.