Monomer conversion and cytotoxicity of dental composites irradiated with different modes of photoactivated curing.

Wan-Yu Tseng1, Chien-Hsun Huang, Ruey-Song Chen, Ming-Shu Lee, Yi-Jane Chen, Frederick A Rueggeberg, Min-Huey Chen.   

Abstract

The aim of the study was to compare the monomer conversion and cytotoxicity of two resin composites, Tetric Ceram (TC) and Heliomolar (HM), irradiated with a halogen light-curing unit (Optilux 501) using a number of curing modes, boost (OB), ramp (OR), and conventional (OC), as well as a light-emitting diode (LED) curing unit (LEDemetron; LEDe). The effects of irradiation times (10, 20, 30, and 40 s) were also investigated. The monomer conversion of resin composites was measured using Fourier transform infrared (FTIR) analysis. Resin samples were preimmersed in Dulbeco's modified engles medium (DMEM) for 24 h, and the periodontal ligament cells (PDL) were cultured with aged medium for 72 h to evaluate the cytotoxic effects of resin samples using the microtiter-tetrazolium (MTT) method. The spectral outputs of the curing units were also compared. After irradiation using the same curing mode, the TC monomer conversion was higher than the HM analog. The TC conversion value was lower after OC and LEDemetron irradiation for 10 s compared to exposures of 30 and 40 s. The HM conversion value was lowest for the 10-s OC irradiation, and highest for the 40-s OC exposure. In cytotoxicity tests, the negative control group was without irradiation. The succinate dehydrogenase (SDH) activities of the OB and OR-irradiated TC samples were significantly lower than analogs irradiated with LEDemetron for 40 s; however, no significant differences were demonstrated between OB, OR, and control groups. Further, no significant differences in SDH activity were demonstrated for OB, OR, and control groups of the HM.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17455271     DOI: 10.1002/jbm.b.30769

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  5 in total

1.  Effect of different polymerization methods on the cytotoxicity of dental composites.

Authors:  Nilufer Celebi Beriat; Ahmet Atila Ertan; Senay Canay; Aylin Gurpinar; Mehmet Ali Onur
Journal:  Eur J Dent       Date:  2010-07

2.  Reaction of rat subcutaneous connective tissue to resin composites polymerized with different light curing units and different lightening methods.

Authors:  Atiyeh Feiz; Farahnaz Arbabzadeh Zavareh; Seyed Mohammad Razavi; Hamid Badrian; Sepideh Dolatyar; Mansoureh Vajihi
Journal:  Int J Dent       Date:  2012-06-14

Review 3.  Molecular toxicology of substances released from resin-based dental restorative materials.

Authors:  Athina Bakopoulou; Triantafillos Papadopoulos; Pavlos Garefis
Journal:  Int J Mol Sci       Date:  2009-09-04       Impact factor: 6.208

4.  Comparative study of surface microhardness of methacrylate-based composite resins polymerized with light-emitting diodes and halogen.

Authors:  Camila Sabatini
Journal:  Eur J Dent       Date:  2013-07

5.  Effect of emitted wavelength and light guide type on irradiance discrepancies in hand-held dental curing radiometers.

Authors:  Atsushi Kameyama; Akiko Haruyama; Masako Asami; Toshiyuki Takahashi
Journal:  ScientificWorldJournal       Date:  2013-10-10
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.