Literature DB >> 17439566

Haemodynamic changes in the second half of pregnancy: a longitudinal, noninvasive study with thoracic electrical bioimpedance.

M N M Volman1, A Rep, I Kadzinska, J Berkhof, H P van Geijn, R M Heethaar, J I P de Vries.   

Abstract

OBJECTIVE: Maternal cardiovascular adaptations to pregnancy are necessary for an adequate fetomaternal circulation. However, the time course of physiological haemodynamic changes during the second half of pregnancy remains unclear. Various methods, invasive and noninvasive, are described to measure these changes. The thoracic electrical bioimpedance (TEB) technique is a method which is especially suitable to measure haemodynamic changes over time. The aim of the study was to determine both individual and group trends of haemodynamic changes in healthy pregnant women during the second half of pregnancy by means of TEB. Outcome variables are heart rate (HR), stroke volume (SV), cardiac output (CO) and blood pressure.
DESIGN: Longitudinal study.
SETTING: Outpatient antenatal care clinic of university hospital. POPULATION: A total of 22 healthy nonsmoking women with an uncomplicated singleton pregnancy and without pre-existing vascular disorders were invited.
METHODS: TEB and blood pressure measurements were performed at each regular visit from about 24 weeks of gestation through term age. MAIN OUTCOME MEASURES: Trends were calculated with the random effects model.
RESULTS: Data obtained from 19 women were analysed, with a median of eight (range 3-11) measurements. HR showed a linear increase (P < 0.0005) and a quadratic trend (P < 0.0005). SV decreased linearly (P = 0.046), without a quadratic course. CO remained stable over time.
CONCLUSION: During the second half of physiological pregnancy, significant trends could be determined. An increase in HR, a decrease in SV, a stable CO and an increase in systolic and diastolic blood pressures were found.

Entities:  

Mesh:

Year:  2007        PMID: 17439566     DOI: 10.1111/j.1471-0528.2007.01300.x

Source DB:  PubMed          Journal:  BJOG        ISSN: 1470-0328            Impact factor:   6.531


  7 in total

1.  Cardiac hemodynamics before, during and after elective cesarean section under spinal anesthesia in low-risk women.

Authors:  M Ram; A Lavie; S Lev; Y Blecher; U Amikam; Y Shulman; T Avnon; E Weiner; A Many
Journal:  J Perinatol       Date:  2017-04-13       Impact factor: 2.521

Review 2.  Maternal cardiac metabolism in pregnancy.

Authors:  Laura X Liu; Zolt Arany
Journal:  Cardiovasc Res       Date:  2014-01-20       Impact factor: 10.787

3.  Impact of gestational risk factors on maternal cardiovascular system.

Authors:  María Perales; Alejandro Santos-Lozano; Fabian Sanchis-Gomar; María Luaces; Helios Pareja-Galeano; Nuria Garatachea; Rubén Barakat; Alejandro Lucia
Journal:  Ann Transl Med       Date:  2016-07

4.  Influence of antenatal physical exercise on haemodynamics in pregnant women: a flexible randomisation approach.

Authors:  Rhiannon Emma Carpenter; Simon J Emery; Orhan Uzun; Lindsay A D'Silva; Michael J Lewis
Journal:  BMC Pregnancy Childbirth       Date:  2015-08-22       Impact factor: 3.007

5.  Noninvasive cardiac monitoring in pregnancy: impedance cardiography versus echocardiography.

Authors:  J Burlingame; P Ohana; M Aaronoff; T Seto
Journal:  J Perinatol       Date:  2013-05-16       Impact factor: 2.521

6.  Effect of passive leg raising on systemic hemodynamics of pregnant women: a dynamic assessment of maternal cardiovascular function at 22-24 weeks of gestation.

Authors:  Åse Vårtun; Kari Flo; Ganesh Acharya
Journal:  PLoS One       Date:  2014-04-14       Impact factor: 3.240

7.  Bioimpedance cardiography in pregnancy: A longitudinal cohort study on hemodynamic pattern and outcome.

Authors:  Martin Andreas; Lorenz Kuessel; Stefan P Kastl; Stefan Wirth; Kathrin Gruber; Franziska Rhomberg; Fatemeh A Gomari-Grisar; Maximilian Franz; Harald Zeisler; Michael Gottsauner-Wolf
Journal:  BMC Pregnancy Childbirth       Date:  2016-06-01       Impact factor: 3.007

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.