OBJECTIVE: The aim of this study was to describe maternal central hemodynamic parameters before and during delivery as well at the early puerperium in healthy women undergoing elective cesarean section (CS) at term. STUDY
DESIGN: The noninvasive Cardiac System (NICaS, NI Medical, Petah-Tikva, Israel) is a regional impedance device that measures cardiac output (CO) and its derivatives with a good correlation with the gold standard Swan-Ganz catheter. We performed a prospective longitudinal study of healthy women with a singleton pregnancy at term. Maternal hemodynamic parameters were assessed by the NICaS at six time points: a few minutes before undergoing an elective CS, immediately after receiving spinal anesthesia, immediately after delivery of the fetus and placenta, after abdominal fascia closure, and within 24 to 36 and 48 to 72 h postpartum. RESULT: Sixty-one consenting women were recruited during the study period (January 2015 to June 2015). Baseline (pre-CS) mean arterial pressure (MAP) was 87.7±7.9 mm Hg, baseline CO was 7.5±1.7 l per min and baseline total peripheral resistance (TPR) was 994±301 dyne × s per cm5. After spinal anesthesia CO significantly increased by 13%, no significant changes were observed in MAP or TPR. Immediately after delivery, a nadir for all parameters was reached: MAP and TPR were significantly reduced by 8% and 26%, respectively (comparing to pre-CS), and CO further increased by 9% (24% comparing to pre-CS). After fascia closure, partial recoveries of all parameters were observed. Twenty-four to thirty-six hours postpartum MAP returned to pre-CS values, while CO and TPR reached -9% and +11% comparing to baseline, respectively. None of the parameters differed significantly between 24 to 36 and 48 to 72 h postpartum.
CONCLUSION: Significant hemodynamic changes (reduction of TPR and increase of CO) take place at the time of delivery of fetus and placenta. Knowledge of normal hemodynamic values using a reliable noninvasive technique during various stages of pregnancy and the postpartum period is feasible, and might assist clinicians in assessing the level of patient deviation from expected cardiac performance, especially in high-risk women.

Entities:  

Mesh:

Year:  2017        PMID: 28406485     DOI: 10.1038/jp.2017.53

Source DB:  PubMed          Journal:  J Perinatol        ISSN: 0743-8346            Impact factor:   2.521


  43 in total

Review 1.  Adaptation of the maternal heart in pregnancy.

Authors:  S Hunter; S C Robson
Journal:  Br Heart J       Date:  1992-12

2.  Maternal haemodynamics in pre-eclampsia compared with normal pregnancy during caesarean delivery.

Authors:  K Tihtonen; T Kööbi; A Yli-Hankala; H Huhtala; J Uotila
Journal:  BJOG       Date:  2006-06       Impact factor: 6.531

3.  A longitudinal study of maternal hemodynamics during normal pregnancy.

Authors:  A C van Oppen; I van der Tweel; G P Alsbach; R M Heethaar; H W Bruinse
Journal:  Obstet Gynecol       Date:  1996-07       Impact factor: 7.661

4.  Central hemodynamic assessment of normal term pregnancy.

Authors:  S L Clark; D B Cotton; W Lee; C Bishop; T Hill; J Southwick; J Pivarnik; T Spillman; G R DeVore; J Phelan
Journal:  Am J Obstet Gynecol       Date:  1989-12       Impact factor: 8.661

5.  Maternal cardiovascular dynamics. 3. Labor and delivery under local and caudal analgesia.

Authors:  K Ueland; J M Hansen
Journal:  Am J Obstet Gynecol       Date:  1969-01-01       Impact factor: 8.661

6.  Early pregnancy changes in hemodynamics and volume homeostasis are consecutive adjustments triggered by a primary fall in systemic vascular tone.

Authors:  J J Duvekot; E C Cheriex; F A Pieters; P P Menheere; L H Peeters
Journal:  Am J Obstet Gynecol       Date:  1993-12       Impact factor: 8.661

Review 7.  Cardiac output in normal pregnancy: a critical review.

Authors:  A C van Oppen; R H Stigter; H W Bruinse
Journal:  Obstet Gynecol       Date:  1996-02       Impact factor: 7.661

8.  Cardiovascular effects of low-dose spinal anaesthesia as a function of age: An observational study using echocardiography.

Authors:  Olivier Lairez; Fabrice Ferré; Nicolas Portet; Philippe Marty; Clément Delmas; Thomas Cognet; Matt Kurrek; Didier Carrié; Olivier Fourcade; Vincent Minville
Journal:  Anaesth Crit Care Pain Med       Date:  2015-09-18       Impact factor: 4.132

9.  When do cardiovascular parameters return to their preconception values?

Authors:  E L Capeless; J F Clapp
Journal:  Am J Obstet Gynecol       Date:  1991-10       Impact factor: 8.661

10.  Atrial natriuretic peptide (ANP) decrease during normal pregnancy as related to hemodynamic changes and volume regulation.

Authors:  J K Thomsen; N Fogh-Andersen; P Jaszczak; J Giese
Journal:  Acta Obstet Gynecol Scand       Date:  1993-02       Impact factor: 3.636

View more
  2 in total

1.  Maternal cardiovascular hemodynamics in normotensive versus preeclamptic pregnancies: a prospective longitudinal study using a noninvasive cardiac system (NICaS™).

Authors:  Anat Lavie; Maya Ram; Shaul Lev; Yair Blecher; Uri Amikam; Yael Shulman; Tomer Avnon; Eran Weiner; Ariel Many
Journal:  BMC Pregnancy Childbirth       Date:  2018-06-14       Impact factor: 3.007

2.  Electrical velocimetry has limited accuracy and precision and moderate trending ability compared with transthoracic echocardiography for cardiac output measurement during cesarean delivery: A prospective observational study.

Authors:  S M Feng; Jin Liu
Journal:  Medicine (Baltimore)       Date:  2020-08-21       Impact factor: 1.817

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.