Assessment of a reflectance photometer in a veterinary laboratory.

C J Belford, J H Lumsden.   

Abstract

This report is an assessment of clinical chemistry dry reagent methodology for veterinary use. A portable reflectance photometer and dry reagent strips were used to measure canine whole blood hemoglobin, and total bilirubin, glucose, cholesterol, creatinine and urea in canine, bovine, equine and feline sera. Creatine kinase and lactate dehydrogenase were assayed in canine, bovine and equine sera. The following aspects of performance are reported: within run variation determined on canine samples, between run variation using a commercial control, correlations between dry reagent and wet reagent methodology on clinical samples, and dry reagent method serum chemistry reference values for the cow, horse and dog. A brief description of some technical advantages and limitations is included.Technical requirements were minimal while reproducibility and accuracy compared well with the wet reagent method. The dry reagent method was found to be suitable for determination of canine, bovine, equine and feline serum variables as listed above.

Entities:  

Year:  1984        PMID: 17422414      PMCID: PMC1790592     

Source DB:  PubMed          Journal:  Can Vet J        ISSN: 0008-5286            Impact factor:   1.008


  5 in total

1.  Evaluation of a reagent-strip method for glucose in whole blood, as compared with a hexokinase method.

Authors:  T C Stewart
Journal:  Clin Chem       Date:  1976-01       Impact factor: 8.327

2.  On establishing reference values.

Authors:  J H Lumsden; K Mullen
Journal:  Can J Comp Med       Date:  1978-07

3.  Whole blood glucose determination in dogs using dextrostix and the eyetone reflectance colorimeter.

Authors:  D B Church; A D Watson
Journal:  J Small Anim Pract       Date:  1979-03       Impact factor: 1.522

4.  Blood glucose measurement: an evaluation of a small reflectance photometer under field conditions.

Authors:  S A Robertson; J N Lucke; G M Hall
Journal:  Vet Rec       Date:  1982-12-11       Impact factor: 2.695

5.  Blood glucose measurement with Dextrostix and new reflectance meter.

Authors:  B Schersten; C Kuhl; A Hollender; R Ekman
Journal:  Br Med J       Date:  1974-08-10
  5 in total
  1 in total

1.  Comparison of Measurements of 12 Analytes in Equine Blood Samples Using the In-Practice Falcor 350 and the Reference KoneLab 30i Analysers.

Authors:  K Papasouliotis; K V Tennant; S Dodkin; J Mason
Journal:  ISRN Vet Sci       Date:  2012-09-27
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.