Blood glucose measurement with Dextrostix and new reflectance meter.

B Schersten, C Kuhl, A Hollender, R Ekman.   

Abstract

A new instrument, Eyetone, has been produced for use with a Dextrostix reagent strip for estimating blood sugar levels. It differs from the Dextrostix Reflectance Meter in having only one meter scale, a two-point calibration, and a range of measurement limited to 10-400 mg/100 ml. Results with the manufacturers' original calibration were unsatisfactory, but when recalibrated the performance of the instrument gave a regression equation line close to the ideal. The three Eyetone instruments tested were comparable in their accuracy and functional stability. Packed cell volumes in the blood samples in the range of 30-50% had a negligible effect on the results. The Dextrostix-Eyetone method represents a quick and reliable alternative to conventional laboratory methods for blood sugar estimation. It is especially useful for patients outside hospital.

Entities:  

Mesh:

Substances:

Year:  1974        PMID: 4850800      PMCID: PMC1613144          DOI: 10.1136/bmj.3.5927.384

Source DB:  PubMed          Journal:  Br Med J        ISSN: 0007-1447


  9 in total

1.  A RAPID ENZYME-STRIP METHOD FOR ESTIMATING BLOOD-SUGAR.

Authors:  I D RENNIE; H KEEN; A SOUTHON
Journal:  Lancet       Date:  1964-10-24       Impact factor: 79.321

2.  ABEDSIDE METHOD OF BLOOD-GLUCOSE ESTIMATION.

Authors:  S L COHEN; S LEGG; R BIRD
Journal:  Lancet       Date:  1964-10-24       Impact factor: 79.321

3.  A DIABETES DETECTION CAMPAIGN IN SOUTHERN SWEDEN. RESULTS OF 69,000 EXAMINATIONS.

Authors:  L BRANDT; A NORDEN; B SCHERSTEN; N TRYDING
Journal:  Acta Med Scand       Date:  1964-11

4.  A PLEA FOR PLASMA SUGAR.

Authors:  E ZALME; H C KNOWLES
Journal:  Diabetes       Date:  1965-03       Impact factor: 9.461

5.  Rapid specific method for determination of aldosaccharides in body fluids.

Authors:  E HULTMAN
Journal:  Nature       Date:  1959-01-10       Impact factor: 49.962

6.  Determination of serum or plasma glucose on the "AutoAnalyzer II" by use of the hexokinase reaction.

Authors:  G M Widdowson; J R Penton
Journal:  Clin Chem       Date:  1972-03       Impact factor: 8.327

7.  Inaccuracy of test strips with reflectance meter in determination of high blood-sugars.

Authors:  K Junker; J Ditzel
Journal:  Lancet       Date:  1972-04-15       Impact factor: 79.321

8.  "Instant" blood sugar measurement using Dextrostix and a reflectance meter.

Authors:  R J Jarrett; H Keen; C Hardwick
Journal:  Diabetes       Date:  1970-10       Impact factor: 9.461

9.  Blood glucose determination in infants and children. The reflectance meter-enzyme test strip system.

Authors:  J C Haworth; L A Dilling; M Van Woert
Journal:  Am J Dis Child       Date:  1972-05
  9 in total
  10 in total

1.  Historical achievements of self-monitoring of blood glucose technology development in Japan.

Authors:  Shigeki Yamada
Journal:  J Diabetes Sci Technol       Date:  2011-09-01

Review 2.  Strategies for the detection of target analytes using microfluidic paper-based analytical devices.

Authors:  Wei Zheng; Kan Wang; Hao Xu; Chujun Zheng; Bo Cao; Qi Qin; Qinghui Jin; Daxiang Cui
Journal:  Anal Bioanal Chem       Date:  2021-03-13       Impact factor: 4.142

3.  Effect of packed cell volume on blood glucose estimations.

Authors:  C M Dacombe; R G Dalton; D J Goldie; J P Osborne
Journal:  Arch Dis Child       Date:  1981-10       Impact factor: 3.791

4.  The response of gastric inhibitory polypeptide (GIP) and insulin to glucose in duodenal ulcer patients.

Authors:  K B Lauritsen; A J Moody
Journal:  Diabetologia       Date:  1978-03       Impact factor: 10.122

5.  The enteral insulin-stimulation after pancreas transplantation in the pig.

Authors:  S L Jensen; O V Nielsen; C Kühl
Journal:  Diabetologia       Date:  1976-12       Impact factor: 10.122

6.  Mechanism of erroneous Dextrostix readings.

Authors:  H Togari; M Oda; Y Wada
Journal:  Arch Dis Child       Date:  1987-04       Impact factor: 3.791

Review 7.  The practical management of glucose-insulin infusions in the intensive care patient.

Authors:  D B McWilliam
Journal:  Intensive Care Med       Date:  1980       Impact factor: 17.440

8.  Diminished gastrointestinal potentiation of insulin secretion in human pregnancy.

Authors:  P Hornnes; C Kühl; J G Klebe
Journal:  Diabetologia       Date:  1978-09       Impact factor: 10.122

9.  Assessment of a reflectance photometer in a veterinary laboratory.

Authors:  C J Belford; J H Lumsden
Journal:  Can Vet J       Date:  1984-06       Impact factor: 1.008

10.  A Plasmonic Fiber Based Glucometer and Its Temperature Dependence.

Authors:  Jisoo Kim; Changjin Son; Sunjak Choi; Won Jung Yoon; Heongkyu Ju
Journal:  Micromachines (Basel)       Date:  2018-10-05       Impact factor: 2.891

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.