Literature DB >> 17414986

Postfusion magnetic resonance imaging artifacts caused by a titanium, cobalt-chromium-molybdenum, and carbon intervertebral disc spacer.

Thorsten Ernstberger1, Gabert Heidrich.   

Abstract

Intervertebral spacers for anterior spine fusion are made of different materials, such as titanium and CoCrMo-alloys or carbon fiber reinforced polymers (CFRP). Implant-related susceptibility artifacts can decrease the quality of magnetic resonance imaging (MRI) scans. This cadaveric study aimed to demonstrate the extent that implant-related MRI artifacting affects the postfusion differentiation of the spinal canal (SC) and intervertebral disc space (IDS). In 6 cadaveric porcine spines, we evaluated the postimplantation MRI scans of a titanium, CoCrMo-spacer and CFRP-spacer that differed in shape and surface qualities. A spacer made of human cortical bone was used as a control. A defined evaluation unit was divided into regions of interest (ROI) to characterize the SC and IDS. Considering 15 different MRI sequences read independently by an interobserver-validated team of specialists artifact-affected image quality of the median MRI slice was rated on a score of 0-1-2-3. A maximum score of 15 points for the SC and 9 points for the IDS (100%) was possible. Turbo spin echo sequences produced the best scores for both spacers and the control. Only the control achieved a score of 100%. For the IDS the CoCrMo-spacer, titanium and CFRP-spacer maximally scored 0%, 0% and 74%, for the SC 60%, 80% and 99%, respectively. By using favored T1 TSE sequences the CFRP-spacer represented clear advantages in postfusion spinal imaging. Independent of artifact dimensions the used scoring system allowed us to create an implant-related ranking of MRI scan quality in reference to the bone control.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17414986     DOI: 10.1097/01.bsd.0000211244.52329.21

Source DB:  PubMed          Journal:  J Spinal Disord Tech        ISSN: 1536-0652


  4 in total

1.  Comparison of spinal anatomy between 3-Tesla MRI and CT-myelography under healthy and pathological conditions.

Authors:  Astrid Ellen Grams; Jens Gempt; Annette Förschler
Journal:  Surg Radiol Anat       Date:  2009-12-06       Impact factor: 1.246

2.  CoCr rods provide better frontal correction of adolescent idiopathic scoliosis treated by all-pedicle screw fixation.

Authors:  Mayalen Lamerain; Manon Bachy; Marion Delpont; Reda Kabbaj; Pierre Mary; Raphaël Vialle
Journal:  Eur Spine J       Date:  2014-01-22       Impact factor: 3.134

3.  Quantifying the effect of posterior spinal instrumentation on the MRI signal of adjacent intervertebral discs.

Authors:  Mary H Foltz; Robert M O'Leary; Diana Reader; Nicholas L Rudolph; Krista A Schlitter; Jutta Ellermann; Casey P Johnson; David W Polly; Arin M Ellingson
Journal:  Spine Deform       Date:  2020-05-24

4.  MR-compatible antibiotic interlocked nail fabrication for the management of long bone infections: first case report of a new technique.

Authors:  Cyril Mauffrey; George W Chaus; Nathan Butler; Heather Young
Journal:  Patient Saf Surg       Date:  2014-03-17
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.