Abstract

OBJECTIVES: Previous experimental studies have demonstrated that poly[bis(trifluoroethoxy)phosphazene] (PTFEP) nanocoated stents have antithrombotic characteristics, reduce in-stent stenosis, prevent wall inflammation, and do not hamper endothelialization. This study was designed to validate these findings in a porcine coronary artery model.
MATERIALS AND METHODS: PTFEP-coated (n = 15) and bare stents (n= 13) were implanted in coronary arteries of 18 mini-pigs (4- and 12-week follow-up). Primary study endpoints were thrombogenicity and in-stent stenosis, secondary study endpoints were inflammatory response and re-endothelialization evaluated by quantitative angiography and light microscopy.
RESULTS: No thrombus deposition occurred on any stent. At 4 weeks follow-up, the bare stents (n = 4) had a significantly smaller neointimal area (1.93 vs. 3.20 mm(2), P = 0.009). At 12 weeks, PTFEP-coated stents (n = 11) had significantly superior results in almost all parameters: neointimal area (2.25 vs. 2.65 mm(2), P = 0.034), neointimal height (204.46 vs. 299.41 microm, P = 0.048), percentage stenosis (38.25 vs. 50.42%, P = 0.019), and inflammation score (0.12 vs. 0.30, P = 0.029). Complete re-endothelialization was seen in both stent types at both intervals.
CONCLUSION: At long-term follow-up, the superior results of PTFEP-coated stents were characterized by a noteworthy reduction of neointimal growth and inflammatory response.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17414526     DOI: 10.1097/01.rli.0000261439.90760.9d

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  5 in total

1.  Anti-biofouling implantable catheter using thin-film magnetic microactuators.

Authors:  Qi Yang; Hyunsu Park; Tran N H Nguyen; Jeffrey F Rhoads; Albert Lee; R Timothy Bentley; Jack W Judy; Hyowon Lee
Journal:  Sens Actuators B Chem       Date:  2018-07-24       Impact factor: 7.460

Review 2.  Recent advances in drug eluting stents.

Authors:  Amey S Puranik; Eileen R Dawson; Nicholas A Peppas
Journal:  Int J Pharm       Date:  2012-10-29       Impact factor: 5.875

Review 3.  Surface engineering at the nanoscale: A way forward to improve coronary stent efficacy.

Authors:  Aleena Mary Cherian; Shantikumar V Nair; Vijayakumar Maniyal; Deepthy Menon
Journal:  APL Bioeng       Date:  2021-06-01

4.  New cross-linkable poly[bis(octafluoropentoxy) phosphazene] biomaterials: Synthesis, surface characterization, bacterial adhesion, and plasma coagulation responses.

Authors:  Li-Chong Xu; Chen Chen; Jieru Zhu; Meixian Tang; Andy Chen; Harry R Allcock; Christopher A Siedlecki
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2020-06-18       Impact factor: 3.405

Review 5.  Anti-thrombogenic coatings for devices in neurointerventional surgery: Case report and review of the literature.

Authors:  Hans Henkes; Pervinder Bhogal; Marta Aguilar Pérez; Tim Lenz-Habijan; Catrin Bannewitz; Marcus Peters; Christina Sengstock; Oliver Ganslandt; Pedro Lylyk; Hermann Monstadt
Journal:  Interv Neuroradiol       Date:  2019-06-27       Impact factor: 1.610