Literature DB >> 17411410

The mask for noninvasive ventilation: principles of design and effects on aerosol delivery.

Dean R Hess1.   

Abstract

There has been much clinical and academic interest in the use of noninvasive positive-pressure ventilation (NPPV) in patients with acute and chronic respiratory failure. The use of NPPV in appropriately selected patients improves survival and decreases the need for endotracheal intubation. The most commonly used interfaces for NPPV are nasal masks or oronasal masks, but nasal pillows, mouthpieces, total face masks, and helmets can also be used. Critical care ventilators, portable volume ventilators, and ventilators designed specifically for NPPV can be used. There are three options for aerosol delivery during NPPV. The patient can be removed from NPPV and the aerosol administered by nebulizer or MDI in the standard manner, the aerosol can be delivered by nebulizer placed in-line between the circuit and the mask, or a spacer chamber can be placed between the circuit and the mask. There is presently no commercially available system designed specifically for aerosol delivery during NPPV with a bilevel (BiPAP) ventilator. However, in vitro and in vivo studies have demonstrated that a significant amount of bronchodilator can be administered by in-line nebulizer or MDI during NPPV. The evidence base for aerosol delivery during NPPV is not nearly as mature as the evidence for aerosol delivery during invasive mechanical ventilation. With NPVV, issues related to the optimal interface, ventilator settings, and aerosol generator (nebulizer versus MDI) are largely unexplored.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17411410     DOI: 10.1089/jam.2007.0574

Source DB:  PubMed          Journal:  J Aerosol Med        ISSN: 0894-2684


  14 in total

1.  Application of an inline dry powder inhaler to deliver high dose pharmaceutical aerosols during low flow nasal cannula therapy.

Authors:  Dale Farkas; Michael Hindle; P Worth Longest
Journal:  Int J Pharm       Date:  2018-05-05       Impact factor: 5.875

2.  Improving the lung delivery of nasally administered aerosols during noninvasive ventilation-an application of enhanced condensational growth (ECG).

Authors:  P Worth Longest; Geng Tian; Michael Hindle
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2011-03-16       Impact factor: 2.849

Review 3.  Devices for Improved Delivery of Nebulized Pharmaceutical Aerosols to the Lungs.

Authors:  Worth Longest; Benjamin Spence; Michael Hindle
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2019-07-09       Impact factor: 2.849

4.  Development of a High-Flow Nasal Cannula and Pharmaceutical Aerosol Combination Device.

Authors:  Benjamin M Spence; Worth Longest; Xiangyin Wei; Sneha Dhapare; Michael Hindle
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2019-03-11       Impact factor: 2.849

5.  Aerosol Drug Delivery During Noninvasive Positive Pressure Ventilation: Effects of Intersubject Variability and Excipient Enhanced Growth.

Authors:  Ross L Walenga; P Worth Longest; Anubhav Kaviratna; Michael Hindle
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2017-01-11       Impact factor: 2.849

6.  High-efficiency generation and delivery of aerosols through nasal cannula during noninvasive ventilation.

Authors:  P Worth Longest; Ross L Walenga; Yoen-Ju Son; Michael Hindle
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2012-12-28       Impact factor: 2.849

7.  The use of condensational growth methods for efficient drug delivery to the lungs during noninvasive ventilation high flow therapy.

Authors:  Laleh Golshahi; Geng Tian; Mandana Azimi; Yoen-Ju Son; Ross Walenga; P Worth Longest; Michael Hindle
Journal:  Pharm Res       Date:  2013-06-26       Impact factor: 4.200

8.  Efficient Nose-to-Lung (N2L) Aerosol Delivery with a Dry Powder Inhaler.

Authors:  P Worth Longest; Laleh Golshahi; Srinivas R B Behara; Geng Tian; Dale R Farkas; Michael Hindle
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2014-09-05       Impact factor: 2.849

9.  Targeted Lung Delivery of Nasally Administered Aerosols.

Authors:  Geng Tian; Michael Hindle; P Worth Longest
Journal:  Aerosol Sci Technol       Date:  2014       Impact factor: 2.908

10.  Improving pharmaceutical aerosol delivery during noninvasive ventilation: effects of streamlined components.

Authors:  P Worth Longest; Laleh Golshahi; Michael Hindle
Journal:  Ann Biomed Eng       Date:  2013-02-20       Impact factor: 3.934

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.