Literature DB >> 17405379

ECG recording on a bed during sleep without direct skin-contact.

Yong Gyu Lim1, Ko Keun Kim, Kwang Suk Park.   

Abstract

A new indirect contact (IDC) electrocardiogram (ECG) measurement method (IDC-ECG) for monitoring ECG during sleep that is adequate for long-term use is provided. The provided method did not require any direct conductive contact between the instrument and bare skin. This method utilizes an array of high-input-impedance active electrodes fixed on the mattress and an indirect-skin-contact ground made of a large conductive textile sheet. A thin cotton bedcover covered the mattress, electrodes, and conductive textile, and the participants were positioned on the mattress over the bedcover. An ECG was successfully obtained, although the signal quality was lower and the motion artifact was larger than in conventional direct-contact measurements (DC-ECG). The results showed that further studies are required to apply the provided method to an ECG diagnosis of cardiovascular diseases. However, currently the method can be used for HRV assessment with easy discrimination of R-peaks.

Entities:  

Mesh:

Year:  2007        PMID: 17405379     DOI: 10.1109/TBME.2006.889194

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  20 in total

1.  Thin and flexible active electrodes with shield for capacitive electrocardiogram measurement.

Authors:  Seung Min Lee; Kyo Sik Sim; Ko Keun Kim; Yong Gyu Lim; Kwang Suk Park
Journal:  Med Biol Eng Comput       Date:  2010-04-02       Impact factor: 2.602

2.  First clinical evaluation of a novel capacitive ECG system in patients with acute myocardial infarction.

Authors:  Mareike B Weil; Martin Oehler; Meinhard Schilling; Lars S Maier
Journal:  Clin Res Cardiol       Date:  2011-11-08       Impact factor: 5.460

Review 3.  Smart health monitoring systems: an overview of design and modeling.

Authors:  Mirza Mansoor Baig; Hamid Gholamhosseini
Journal:  J Med Syst       Date:  2013-01-15       Impact factor: 4.460

4.  Activation of extracellular signal-regulated kinase signaling in the pedunculopontine tegmental cells is involved in the maintenance of sleep in rats.

Authors:  Frank Desarnaud; Brian W Macone; Subimal Datta
Journal:  J Neurochem       Date:  2011-01-19       Impact factor: 5.372

Review 5.  Recent Advances in Stretchable and Wearable Capacitive Electrophysiological Sensors for Long-Term Health Monitoring.

Authors:  Hadaate Ullah; Md A Wahab; Geoffrey Will; Mohammad R Karim; Taisong Pan; Min Gao; Dakun Lai; Yuan Lin; Mahdi H Miraz
Journal:  Biosensors (Basel)       Date:  2022-08-11

6.  Mobile cloud-computing-based healthcare service by noncontact ECG monitoring.

Authors:  Ee-May Fong; Wan-Young Chung
Journal:  Sensors (Basel)       Date:  2013-12-02       Impact factor: 3.576

7.  Flexible capacitive electrodes for minimizing motion artifacts in ambulatory electrocardiograms.

Authors:  Jeong Su Lee; Jeong Heo; Won Kyu Lee; Yong Gyu Lim; Youn Ho Kim; Kwang Suk Park
Journal:  Sensors (Basel)       Date:  2014-08-12       Impact factor: 3.576

8.  A Novel Algorithm for Movement Artifact Removal in ECG Signals Acquired from Wearable Systems Applied to Horses.

Authors:  Antonio Lanata; Andrea Guidi; Paolo Baragli; Gaetano Valenza; Enzo Pasquale Scilingo
Journal:  PLoS One       Date:  2015-10-20       Impact factor: 3.240

9.  A Hygroscopic Sensor Electrode for Fast Stabilized Non-Contact ECG Signal Acquisition.

Authors:  Ee-May Fong; Wan-Young Chung
Journal:  Sensors (Basel)       Date:  2015-08-05       Impact factor: 3.576

10.  Extractions of steady-state auditory evoked fields in normal subjects and tinnitus patients using complementary ensemble empirical mode decomposition.

Authors:  Kuo-Wei Wang; Hsiao-Huang Chang; Chuan-Chih Hsu; Kuang-Chao Chen; Jen-Chuen Hsieh; Lieber Po-Hung Li; Po-Lei Lee; An-Suey Shiao
Journal:  Biomed Eng Online       Date:  2015-07-26       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.