Alumina femoral head fracture in uncemented total hip arthroplasty with a ceramic sandwich cup.

Deuk-Soo Hwang1, Young-Mo Kim, Chang-Hwan Lee.   

Abstract

In total hip arthroplasty, insertion of a UHMWPE-coated ceramic sandwich liner dramatically reduces any risk related to the stiffness of the ceramic-ceramic coupling. We present a case of an alumina ceramic head fracture with a ceramic sandwich cup. The fracture occurred 16 months after the initial operation, without trauma. Impingement between the neck and posteroinferior portion of the liner rim had occurred. This was related to the traditional cross-legged sitting position of Koreans, which caused impingement between the neck and liner rim. Consequently, the taper became loose, and the resulting force bent the taper and fractured the head. We examined a peculiar case of ceramic femoral head fracture after implantation of an uncemented total hip arthroplasty with a ceramic sandwich cup and investigated the underlying cause.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17400106     DOI: 10.1016/j.arth.2006.05.020

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  11 in total

1.  Wear degradation of long-term in vivo exposed alumina-on-alumina hip joints: linking nanometer-scale phenomena to macroscopic joint design.

Authors:  Yasuhito Takahashi; Nobuhiko Sugano; Wenliang Zhu; Takashi Nishii; Takashi Sakai; Masaki Takao; Giuseppe Pezzotti
Journal:  J Mater Sci Mater Med       Date:  2011-11-22       Impact factor: 3.896

2.  Fractures of a sandwich ceramic liner at ten year follow-up.

Authors:  Anthony Viste; Julien Chouteau; Romain Desmarchelier; Michel-Henri Fessy
Journal:  Int Orthop       Date:  2011-10-20       Impact factor: 3.075

3.  Experience with sandwich liner and its high rate of failure.

Authors:  John Junghun Shin; Ji-Soo Shin; Jae-Hyun Kim; Sung Kwan Hwang
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-07-16

4.  Imaging of ceramic liner fractures in total hip arthroplasty: the value of CT.

Authors:  Yoshimi Endo; Lisa Renner; Tom Schmidt-Braekling; Douglas N Mintz; Friedrich Boettner
Journal:  Skeletal Radiol       Date:  2015-03-07       Impact factor: 2.199

5.  Non-traumatic Ceramic Head Fracture in Total Hip Arthroplasty with Ceramic-on-Ceramic Articulation at Postoperative 16th Years.

Authors:  Onur Kocadal; Turhan Ozler; Alp Er Tunga Bolukbasi; Faik Altintas
Journal:  Hip Pelvis       Date:  2019-05-30

6.  THA with Delta ceramic on ceramic: results of a multicenter investigational device exemption trial.

Authors:  William G Hamilton; James P McAuley; Douglas A Dennis; Jeffrey A Murphy; Thomas J Blumenfeld; Joel Politi
Journal:  Clin Orthop Relat Res       Date:  2009-09-19       Impact factor: 4.176

Review 7.  [The problem of fractures of ceramic heads. What should be done?].

Authors:  H R Dürr
Journal:  Orthopade       Date:  2009-08       Impact factor: 1.087

8.  Severe impingement of lumbar disc replacements increases the functional biological activity of polyethylene wear debris.

Authors:  Ryan M Baxter; Daniel W Macdonald; Steven M Kurtz; Marla J Steinbeck
Journal:  J Bone Joint Surg Am       Date:  2013-06-05       Impact factor: 5.284

9.  Traumatic ceramic femoral head fracture: an initial misdiagnosis.

Authors:  Mohammad H Fard-Aghaie; Mustafa Citak; Joao Correia; Carl Haasper; Thorsten Gehrke; Daniel Kendoff
Journal:  Open Orthop J       Date:  2012-08-10

Review 10.  Fracture of ceramic bearing surfaces following total hip replacement: a systematic review.

Authors:  Francesco Traina; Marcello De Fine; Alberto Di Martino; Cesare Faldini
Journal:  Biomed Res Int       Date:  2013-06-13       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.