Literature DB >> 17393153

Improvement of the liquid-chromatographic analysis of protein tryptic digests by the use of long-capillary monolithic columns with UV and MS detection.

M H M van de Meent1, G J de Jong.   

Abstract

Optimisation of peak capacity is an important strategy in gradient liquid chromatography (LC). This can be achieved by using either long columns or columns packed with small particles. Monolithic columns allow the use of long columns at relatively low back-pressure. The gain in peak capacity using long columns was evaluated by the separation of a tryptic bovine serum albumin digest with an LC-UV-mass spectrometry (MS) system and monolithic columns of different length (150 and 750 mm). Peak capacities were determined from UV chromatograms and MS/MS data were used for Mascot database searching. Analyses with a similar gradient slope for the two columns produced ratios of the peak capacities that were close to the expected value of the square root of the column length ratio. Peak capacities of the short column were 12.6 and 25.0 with 3 and 15 min gradients, respectively, and 29.7 and 41.0 for the long column with 15 and 75 min gradients, respectively. Protein identification scores were also higher for the long column, 641 and 750 for the 3- and 15-min gradients with the short column and 1,376 and 993 for the 15- and 75-min gradients with the long column. Thus, the use of long monolithic columns provides improved peptide separation and increased reliability of protein identification.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17393153      PMCID: PMC1914286          DOI: 10.1007/s00216-007-1215-1

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  18 in total

1.  Packed capillary reversed-phase liquid chromatography with high-performance electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry for proteomics.

Authors:  Y Shen; R Zhao; M E Belov; T P Conrads; G A Anderson; K Tang; L Pasa-Tolić; T D Veenstra; M S Lipton; H R Udseth; R D Smith
Journal:  Anal Chem       Date:  2001-04-15       Impact factor: 6.986

2.  Protein identification using 2D-LC-MS/MS.

Authors:  Claire Delahunty; John R Yates
Journal:  Methods       Date:  2005-01-12       Impact factor: 3.608

3.  Proteomic analysis with integrated multiple dimensional liquid chromatography/mass spectrometry based on elution of ion exchange column using pH steps.

Authors:  Jie Dai; Chia Hui Shieh; Quan-Hu Sheng; Hu Zhou; Rong Zeng
Journal:  Anal Chem       Date:  2005-09-15       Impact factor: 6.986

4.  A practical approach to maximizing peak capacity by using long columns packed with pellicular stationary phases for proteomic research.

Authors:  Xiaoli Wang; William E Barber; Peter W Carr
Journal:  J Chromatogr A       Date:  2006-01-10       Impact factor: 4.759

5.  Fast LC separation of a myoglobin digest: a case study using monolithic and particulate RP 18 silica capillary columns.

Authors:  Johan Rozenbrand; Wouter P van Bennekom; Klaus K Unger; Gerhardus J de Jong
Journal:  Anal Bioanal Chem       Date:  2006-05-31       Impact factor: 4.142

Review 6.  Proteomics based on high-efficiency capillary separations.

Authors:  Yufeng Shen; Richard D Smith
Journal:  Electrophoresis       Date:  2002-09       Impact factor: 3.535

7.  Two-dimensional SEC/RPLC coupled to mass spectrometry for the analysis of peptides.

Authors:  G J Opiteck; J W Jorgenson
Journal:  Anal Chem       Date:  1997-07-01       Impact factor: 6.986

8.  Large-scale analysis of the yeast proteome by multidimensional protein identification technology.

Authors:  M P Washburn; D Wolters; J R Yates
Journal:  Nat Biotechnol       Date:  2001-03       Impact factor: 54.908

9.  Reversed-phase liquid chromatographic separation of complex samples by optimizing temperature and gradient time I. Peak capacity limitations.

Authors:  J W Dolan; L R Snyder; N M Djordjevic; D W Hill; T J Waeghe
Journal:  J Chromatogr A       Date:  1999-10-01       Impact factor: 4.759

10.  Silica-based monoliths for rapid peptide screening by capillary liquid chromatography hyphenated with electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Felix C Leinweber; Dietmar G Schmid; Dieter Lubda; Karl-Heinz Wiesmüller; Günther Jung; Ulrich Tallarek
Journal:  Rapid Commun Mass Spectrom       Date:  2003       Impact factor: 2.419

View more
  2 in total

1.  Potential of poly(styrene-co-divinylbenzene) monolithic columns for the LC-MS analysis of protein digests.

Authors:  Michiel H M van de Meent; Sebastiaan Eeltink; Gerhardus J de Jong
Journal:  Anal Bioanal Chem       Date:  2010-12-24       Impact factor: 4.142

2.  Quantitative Phosphoproteomics to Study cAMP Signaling.

Authors:  Katharina Schleicher; Svenja Hester; Monika Stegmann; Manuela Zaccolo
Journal:  Methods Mol Biol       Date:  2022
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.