Clarification of aspects in in-line phase-sensitive x-ray imaging.

Xizeng Wu1, Hong Liu.   

Abstract

In this report we clarify two aspects for in-line phase-sensitive x-ray imaging, which includes phase-contrast imaging and phase imaging. First, we point out that there is confusion in the literature about the lateral coherence length, which is widely adopted as the coherence criteria for implementing phase-sensitive imaging. The confusion exaggerates the coherence requirement for clinical implementation of in-line phase-sensitive imaging. Instead we show that the ratio of the phase-space shearing length to lateral coherence length is a good measure for gauging the partial coherence realized in a specific image setting. Second, based on the general intensity equation for in-line phase-sensitive imaging, we discuss the differences between the phase-contrast imaging and phase imaging in terms of the physics mechanism, image acquisition approaches, computation algorithm development, and the potentials for tissue quantitative characterization.

Mesh:

Year:  2007        PMID: 17388191     DOI: 10.1118/1.2431475

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  16 in total

1.  Higher-order phase shift reconstruction approach.

Authors:  Wenxiang Cong; Ge Wang
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

2.  Analytical reconstructions of intensity modulated x-ray phase-contrast imaging of human scale phantoms.

Authors:  Bartłomiej Włodarczyk; Jakub Pietrzak
Journal:  Biomed Opt Express       Date:  2015-10-05       Impact factor: 3.732

3.  Emerging Breast Imaging Technologies on the Horizon.

Authors:  Srinivasan Vedantham; Andrew Karellas
Journal:  Semin Ultrasound CT MR       Date:  2017-09-13       Impact factor: 1.875

4.  Characterization of Continuous and Pulsed Emission modes of a Hybrid Micro Focus X-ray Source for Medical Imaging Applications.

Authors:  Muhammad U Ghani; Molly D Wong; Liqiang Ren; Di Wu; Bin Zheng; John X Rong; Xizeng Wu; Hong Liu
Journal:  Nucl Instrum Methods Phys Res A       Date:  2017-02-16       Impact factor: 1.455

5.  Low dose high energy x-ray in-line phase sensitive imaging prototype: Investigation of optimal geometric conditions and design parameters.

Authors:  Muhammad U Ghani; Aimin Yan; Molly D Wong; Yuhua Li; Liqiang Ren; Xizeng Wu; Hong Liu
Journal:  J Xray Sci Technol       Date:  2015       Impact factor: 1.535

6.  Dose and detectability improvements with high energy phase sensitive x-ray imaging in comparison to low energy conventional imaging.

Authors:  Molly Donovan Wong; Aimin Yan; Muhammad Ghani; Yuhua Li; Laurie Fajardo; Xizeng Wu; Hong Liu
Journal:  Phys Med Biol       Date:  2014-04-15       Impact factor: 3.609

7.  Phase-contrast and magnification radiography at diagnostic X-ray energies using a pseudo-microfocus X-ray source.

Authors:  C J Kotre; K J Robson
Journal:  Br J Radiol       Date:  2014-04-29       Impact factor: 3.039

8.  Detectability comparison between a high energy x-ray phase sensitive and mammography systems in imaging phantoms with varying glandular-adipose ratios.

Authors:  Muhammad U Ghani; Molly D Wong; Di Wu; Bin Zheng; Laurie L Fajardo; Aimin Yan; Janis Fuh; Xizeng Wu; Hong Liu
Journal:  Phys Med Biol       Date:  2017-04-05       Impact factor: 3.609

Review 9.  Breast cancer imaging: a perspective for the next decade.

Authors:  Andrew Karellas; Srinivasan Vedantham
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

10.  Detectability comparison of simulated tumors in digital breast tomosynthesis using high-energy X-ray inline phase sensitive and commercial imaging systems.

Authors:  Muhammad U Ghani; Molly D Wong; Farid H Omoumi; Bin Zheng; Laurie L Fajardo; Aimin Yan; Xizeng Wu; Hong Liu
Journal:  Phys Med       Date:  2018-02-23       Impact factor: 2.685

View more