Literature DB >> 17377024

Semiquantitative assessment of first-pass renal perfusion at 1.5 T: comparison of 2D saturation recovery sequences with and without parallel imaging.

Henrik J Michaely1, Harald Kramer, Niels Oesingmann, Klaus-Peter Lodemann, Maximilian F Reiser, Stefan O Schoenberg.   

Abstract

OBJECTIVE: The purpose of this study was to assess the feasibility and reliability of measurements performed with true fast imaging with steady-state free precession (FISP) and turbo fast low-angle shot (FLASH) sequences with parallel imaging compared with those obtained with turbo FLASH sequences without parallel imaging in first-pass renal perfusion MRI. SUBJECTS AND METHODS: The subjects in this prospective study were 15 healthy men who volunteered to undergo MRI for acquisition of renal perfusion measurements. Imaging was performed at 1.5 T with the following three techniques after administration of gadobenate dimeglumine at 4 mL/s: saturation recovery (SR) turbo FLASH sequences without parallel imaging, SR turbo FLASH sequences with parallel imaging, and SR true FISP sequences. The spatial resolution was 2.3 x 2.6 x 8 mm with a temporal resolution of four slices per second (turbo FLASH without parallel imaging and true FISP) or six slices per second (turbo FLASH with parallel imaging). The semiquantitative perfusion parameters mean transit time and maximal upslope were determined. Signal-to-noise ratio (SNR), delta ratio, and time to maximal signal intensity also were determined. Image quality was rated in consensus.
RESULTS: Image quality was best for turbo FLASH sequences without parallel imaging compared with true FISP and turbo FLASH sequences with parallel imaging. True FISP sequences yielded the highest baseline SNR (26.7) but the lowest delta ratio (3.2). Turbo FLASH sequences without and with parallel imaging had significantly lower SNRs (9.6 and 9.3) and significantly higher delta ratios (5.1 and 5.0). The first-pass perfusion parameters mean transit time and time to maximal signal intensity were independent of the technique used.
CONCLUSION: It seems that at 1.5 T, turbo FLASH sequences without parallel imaging are the best approach to renal first-pass perfusion imaging.

Entities:  

Mesh:

Year:  2007        PMID: 17377024     DOI: 10.2214/AJR.06.0567

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  4 in total

Review 1.  Contrast-enhanced ultrasound: A promising method for renal microvascular perfusion evaluation.

Authors:  Ling Wang; Chandra Mohan
Journal:  J Transl Int Med       Date:  2016-09-23

2.  MR measures of renal perfusion, oxygen bioavailability and total renal blood flow in a porcine model: noninvasive regional assessment of renal function.

Authors:  Andrew L Wentland; Nathan S Artz; Sean B Fain; Thomas M Grist; Arjang Djamali; Elizabeth A Sadowski
Journal:  Nephrol Dial Transplant       Date:  2011-05-28       Impact factor: 5.992

3.  Quantitative MR measures of intrarenal perfusion in the assessment of transplanted kidneys: initial experience.

Authors:  Andrew L Wentland; Elizabeth A Sadowski; Arjang Djamali; Thomas M Grist; Bryan N Becker; Sean B Fain
Journal:  Acad Radiol       Date:  2009-06-17       Impact factor: 3.173

Review 4.  Assessment of renal function with dynamic contrast-enhanced MR imaging.

Authors:  Louisa Bokacheva; Henry Rusinek; Jeff L Zhang; Vivian S Lee
Journal:  Magn Reson Imaging Clin N Am       Date:  2008-11       Impact factor: 2.266

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.