Literature DB >> 17354828

2D/3D registration for measurement of implant alignment after total hip replacement.

Branislav Jaramaz1, Kort Eckman.   

Abstract

Measurements of cup alignment after total hip replacement (THR) surgery are typically performed on postoperative pelvic radiographs. Radiographic measurement of cup orientation depends on the position and orientation of the pelvis on the X-ray table, and its variability could introduce significant measurement errors. We have developed a tool to accurately measure 3D implant orientation from postoperative antero-posterior radiographs by registering to preoperative CT scans. The purpose of this study is to experimentally and clinically validate the automatic CT/X-ray matching algorithm by comparing the X-ray based measurements of cup orientation with direct 3D measurements from postoperative CT scans. The mean measurement errors (+/- stdev) found in this study were 0.4 degrees +/-0.8 degrees for abduction and 0.6 degrees +/- 0.8 degrees for version. In addition, radiographic pelvic orientation measurements demonstrated a wide range of inter-subject variability, with pelvic flexion ranging from -5.9 degrees to 11.2 degrees.

Mesh:

Year:  2006        PMID: 17354828     DOI: 10.1007/11866763_80

Source DB:  PubMed          Journal:  Med Image Comput Comput Assist Interv


  9 in total

1.  Assessing the accuracy factors in the determination of postoperative acetabular cup orientation using hybrid 2D-3D registration.

Authors:  Guoyan Zheng
Journal:  J Digit Imaging       Date:  2009-07-21       Impact factor: 4.056

2.  Computer assisted determination of acetabular cup orientation using 2D-3D image registration.

Authors:  Guoyan Zheng; Xuan Zhang
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-02-24       Impact factor: 2.924

3.  Plan in 2-D, execute in 3-D: an augmented reality solution for cup placement in total hip arthroplasty.

Authors:  Javad Fotouhi; Clayton P Alexander; Mathias Unberath; Giacomo Taylor; Sing Chun Lee; Bernhard Fuerst; Alex Johnson; Greg Osgood; Russell H Taylor; Harpal Khanuja; Mehran Armand; Nassir Navab
Journal:  J Med Imaging (Bellingham)       Date:  2018-01-04

4.  Known-component 3D-2D registration for quality assurance of spine surgery pedicle screw placement.

Authors:  A Uneri; T De Silva; J W Stayman; G Kleinszig; S Vogt; A J Khanna; Z L Gokaslan; J-P Wolinsky; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2015-09-30       Impact factor: 3.609

5.  Validation of a statistical shape model-based 2D/3D reconstruction method for determination of cup orientation after THA.

Authors:  G Zheng; J von Recum; L-P Nolte; P A Grützner; S D Steppacher; J Franke
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-07-27       Impact factor: 2.924

6.  Clinical validation of computer-assisted navigation in total hip arthroplasty.

Authors:  Eric Beaumont; Pierre Beaumont; Daniel Odermat; Isabelle Fontaine; Herbert Jansen; François Prince
Journal:  Adv Orthop       Date:  2010-11-04

7.  Comparison between Novice and Experienced Surgeons Performing Corrective Osteotomy with Patient-Specific Guides in Dogs Based on Resulting Position Accuracy.

Authors:  Yoon Ho Roh; Cheong Woon Cho; Chang Hun Ryu; Je Hun Lee; Seong Mok Jeong; Hae Beom Lee
Journal:  Vet Sci       Date:  2021-02-28

8.  A Hybrid 3D-2D Image Registration Framework for Pedicle Screw Trajectory Registration between Intraoperative X-ray Image and Preoperative CT Image.

Authors:  Roshan Ramakrishna Naik; Anitha Hoblidar; Shyamasunder N Bhat; Nishanth Ampar; Raghuraj Kundangar
Journal:  J Imaging       Date:  2022-07-06

Review 9.  Navigated cup implantation in hip arthroplasty.

Authors:  Johannes Beckmann; Dirk Stengel; Markus Tingart; Jürgen Götz; Joachim Grifka; Christian Lüring
Journal:  Acta Orthop       Date:  2009-10       Impact factor: 3.717

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.