Literature DB >> 17354643

Fast and accurate automatic registration for MR-guided procedures using active microcoils.

Sascha Krueger1, Stephan Wolff, Arno Schmitgen, Holger Timinger, Martin Bublat, Tobias Schaeffter, Arya Nabavi.   

Abstract

A fast, robust, accurate, and automatic registration technique based on magnetic resonance (MR) active microcoils (active markers) for registration of tracked medical devices to preprocedural MR-images is presented. This allows for a straight-forward integration of position measurement systems into clinical procedures. The presented method is useful for guidance purposes in clinical applications with high demands on accuracy and ease-of-use (e.g., neurosurgical or orthopedic applications). The determination of the positions of the active markers is integrated into the preparation phase of the actual MR imaging scan. The technique features a generic interface using DICOM standards for communication with navigation workstations linked to an MR system. The position of the active markers is fixed with respect to a reference system of an optical positioning measurement system (OPMS) and thus the coregistration of the MR system and the OPMS is established. In a phantom study, a mean overall targeting accuracy of 0.9+/-0.1 mm was achieved and compared favorably to results obtained from manual registration tests (1.8+/-0.3 mm) carried out in parallel. For a test person trained for both registration methods, workflow improvements of 3-6 min per registration step were found. The need for manual interaction is entirely eliminated thus avoiding user-bias, which is advantageous for the usage in clinical routine. The method improves the ease-of-use of tracking equipment during stereotactic guidance. The method is finally demonstrated in a volunteer study using a model of a Mayfield skull clamp with integrated active and optical reference markers.

Entities:  

Mesh:

Year:  2007        PMID: 17354643     DOI: 10.1109/TMI.2006.889748

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  5 in total

1.  Prospective motion correction using tracking coils.

Authors:  Lei Qin; Ehud J Schmidt; Zion Tsz Ho Tse; Juan Santos; William S Hoge; Clare Tempany-Afdhal; Kim Butts-Pauly; Charles L Dumoulin
Journal:  Magn Reson Med       Date:  2012-05-07       Impact factor: 4.668

2.  Echo-planar imaging with prospective slice-by-slice motion correction using active markers.

Authors:  Melvyn B Ooi; Sascha Krueger; Jordan Muraskin; William J Thomas; Truman R Brown
Journal:  Magn Reson Med       Date:  2011-02-24       Impact factor: 4.668

3.  Prospective active marker motion correction improves statistical power in BOLD fMRI.

Authors:  Jordan Muraskin; Melvyn B Ooi; Robin I Goldman; Sascha Krueger; William J Thomas; Paul Sajda; Truman R Brown
Journal:  Neuroimage       Date:  2012-12-05       Impact factor: 6.556

4.  Prospective real-time correction for arbitrary head motion using active markers.

Authors:  Melvyn B Ooi; Sascha Krueger; William J Thomas; Srirama V Swaminathan; Truman R Brown
Journal:  Magn Reson Med       Date:  2009-10       Impact factor: 4.668

5.  Prospective real-time head motion correction using inductively coupled wireless NMR probes.

Authors:  Saikat Sengupta; Sasidhar Tadanki; John C Gore; E Brian Welch
Journal:  Magn Reson Med       Date:  2013-11-18       Impact factor: 4.668

  5 in total