Literature DB >> 1735213

Titanium hip implants for improved magnetic resonance and computed tomography examinations.

N A Ebraheim1, E R Savolaine, J Zeiss, W T Jackson.   

Abstract

The value of magnetic resonance imaging (MRI) for assessment of the hip has been demonstrated, particularly in cases of avascular necrosis. Magnetic resonance imaging can be used to provide anatomic evaluation of the femoral head, acetabulum, hip joint, joint fluid, and the surrounding structures. MR examinations of two patients with hip fractures fixed with stainless steel hip implants were compared with nine patients with hip fractures fixed with titanium hip implants, one of which showed avascular necrosis of the femoral head. The titanium implants resulted in less MRI artifacts, allowing for improved depiction of the femoral head and surrounding soft tissue. For this reason titanium fixation devices are recommended as a substitute for stainless steel in the hip joint region in a patient who may need future MR examination.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1735213

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  7 in total

1.  Magnetic resonance imaging (MRI) artefacts in hip prostheses: a comparison of different prosthetic compositions.

Authors:  Elisabetta Panfili; Laura Pierdicca; Luca Salvolini; Luigi Imperiale; Jeffrey Dubbini; Andrea Giovagnoni
Journal:  Radiol Med       Date:  2013-12-03       Impact factor: 3.469

Review 2.  Imaging near orthopedic hardware.

Authors:  Matthew F Koff; Alissa J Burge; Kevin M Koch; Hollis G Potter
Journal:  J Magn Reson Imaging       Date:  2017-02-02       Impact factor: 4.813

3.  What is the role of magnetic resonance imaging in the evaluation of total hip arthroplasty?

Authors:  Hollis G Potter; Li F Foo; Bryan J Nestor
Journal:  HSS J       Date:  2005-09

4.  Artifacts in magnetic resonance imaging of the spine after surgery with or without implant.

Authors:  H Leclet
Journal:  Eur Spine J       Date:  1994       Impact factor: 3.134

5.  Torque property of titanium alloy cerebral aneurysm clips in a magnetic resonance scanner.

Authors:  Minghui Tang; Shingo Kawahira; Naoyuki Nomura; Toru Yamamoto
Journal:  J Mater Sci Mater Med       Date:  2019-12-14       Impact factor: 3.896

6.  Imaging in peri-prosthetic assessment: an orthopaedic perspective.

Authors:  Christoph H Lohmann; Sanjiv Rampal; Martin Lohrengel; Gurpal Singh
Journal:  EFORT Open Rev       Date:  2017-05-11

Review 7.  Clinical Application of Diagnostic Imaging of Chiari-Like Malformation and Syringomyelia.

Authors:  Clare Rusbridge; Felicity Stringer; Susan P Knowler
Journal:  Front Vet Sci       Date:  2018-11-28
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.