Literature DB >> 17338718

Laser lead extraction: predictors of success and complications.

Jean-François Roux1, Pierre Pagé, Marc Dubuc, Bernard Thibault, Peter G Guerra, Laurent Macle, Denis Roy, Mario Talajic, Paul Khairy.   

Abstract

BACKGROUND: Paralleling the rise in pacemaker and defibrillator implantations, lead extraction procedures are increasingly required. Concerns regarding failure and complications remain. METHODS AND
RESULTS: A total of 200 lead extraction procedures were performed at the Montreal Heart Institute between September 2000 and August 2005. In 23 patients, all leads were removed by traction with a locking stylet. A total of 270 leads were extracted using a laser sheath system (Spectranectics, Colorado Springs, CO, USA) in 177 procedures involving 175 patients (74% male), age 62+/-16 years. Procedural indications were: infection 88 (50%), dysfunction 54 (30%), upgrade 21 (12%), and other 14 (8%). Overall, 241 leads (89%) were successfully extracted, 7 (3%) were partially extracted (< or = 4 cm retained), and 22 (8%) were non-extractable. In multivariate analyses, predictors of failed extraction were longer time from implant (OR 1.16 per year, P=0.0001) and history of hypertension (OR 5.2, P=0.0023). Acute complications occurred in 14 of 177 procedures (7.9%): 8 (4.5%) minor and 6 (3.4%) major, with one death. In multivariate analyses, the only predictor of acute complications was laser lead extraction from both right and left sides during the same procedure (OR 9.4, P = 0.0119). In addition, 3 of 10 patients with failed or partially extracted infected systems eventually required open chest explantation because of endocarditis.
CONCLUSION: Most leads not amenable to manual traction may be successfully extracted by a percutaneous laser sheath system. While most complications are minor, major complications including death may occur. Older leads are at higher risk for failed extraction. Endocarditis may ensue if infected leads are incompletely removed.

Entities:  

Mesh:

Year:  2007        PMID: 17338718     DOI: 10.1111/j.1540-8159.2007.00652.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  11 in total

Review 1.  [ICD lead defects: diagnosis and therapeutical options].

Authors:  Christian G Wollmann; Dirk Böcker; Andreas Löher; Hans H Scheld; Günter Breithardt; Rainer Gradaus
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2009-02-11

2.  Creation of the sole regional laser lead extraction program serving Atlantic Canada: initial experience.

Authors:  Kenneth J Williams; Scott O'Keefe; Jean-Francois Légaré
Journal:  Can J Surg       Date:  2016-06       Impact factor: 2.089

3.  Long-term outcome of complete cardiovascular implantable electronic device removal with cardiopulmonary bypass.

Authors:  Masaho Okada; Yuji Narita; Yoshimori Araki; Hideki Oshima; Akihiko Usui; Yuichi Ueda
Journal:  J Artif Organs       Date:  2013-01-20       Impact factor: 1.731

4.  Fistula from right internal mammary artery to superior vena cava after use of a laser sheath to extract a pacemaker lead.

Authors:  Federico E Azpurua; Kathryn G Dougherty; Ali Massumi; Neil E Strickman
Journal:  Tex Heart Inst J       Date:  2012

5.  Lead extractions in patients with cardiac implantable electronic device infections: Single center experience.

Authors:  Masahiko Goya; Michio Nagashima; Ken-Ichi Hiroshima; Kentaro Hayashi; Yu Makihara; Masato Fukunaga; Yoshimori An; Masatsugu Ohe; So-Ichiro Yamazato; Ko-Ichiro Sonoda; Kennosuke Yamashita; Kouji Katayama; Tomoaki Ito; Harushi Niu; Kenji Ando; Hiroyoshi Yokoi; Masashi Iwabuchi
Journal:  J Arrhythm       Date:  2016-03-22

6.  Partial extravenous course of cardiac pacemaker leads. A major risk during device-assisted extraction.

Authors:  Jean-Sylvain Hermida; Thierry Caus; Sarah Traullé; Maciej Kubala
Journal:  HeartRhythm Case Rep       Date:  2015-08-28

7.  Frequency and clinical impact of retained implantable cardioverter defibrillator lead materials in heart transplant recipients.

Authors:  Jun Kim; Jongmin Hwang; Jin Hee Choi; Hyo-In Choi; Min-Seok Kim; Sung-Ho Jung; Gi-Byoung Nam; Kee-Joon Choi; Jae Won Lee; You-Ho Kim; Jae-Joong Kim
Journal:  PLoS One       Date:  2017-05-02       Impact factor: 3.240

8.  Successful pacemaker lead extraction involving an ossified thrombus: A case report.

Authors:  Hideo Okamura; John S Van Arnam; Marie Christine Aubry; Paul A Friedman; Yong-Mei Cha
Journal:  J Arrhythm       Date:  2016-08-30

9.  Editorial: What makes transvenous extraction more difficult?

Authors:  Hideo Okamura
Journal:  J Cardiol Cases       Date:  2015-12-04

10.  Deaths and cardiovascular injuries due to device-assisted implantable cardioverter-defibrillator and pacemaker lead extraction.

Authors:  Robert G Hauser; William T Katsiyiannis; Charles C Gornick; Adrian K Almquist; Linda M Kallinen
Journal:  Europace       Date:  2009-11-27       Impact factor: 5.214

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.