Literature DB >> 17338716

Venous obstruction after pacemaker implantation.

Petri Korkeila1, Kai Nyman, Antti Ylitalo, Juhani Koistinen, Pasi Karjalainen, Juha Lund, K E Juhani Airaksinen.   

Abstract

BACKGROUND: Central vein leads are known to predispose to venous obstruction. Although usually asymptomatic, obstruction may render electrode removal difficult. This study aimed at quantifying changes in venous calibers in a prospective fashion by intravenous contrast venography (ICV) before and after pacemaker (PM) or cardioverter-defibrillator implantation.
METHODS: One hundred and fifty (mean age 67; 61% male) consecutive patients were enrolled, and followed for 6 months. A successful ICV was done at baseline prior to implantation and at 6-month follow-up in 136 (91%) patients. Minimum (D(min)) and maximum (D(max)) vessel diameters were obtained from both ICVs. A new stenosis was defined as a 50% diameter reduction in a venous segment when compared to baseline. We implanted a total of 230 electrodes: 47 (34.6%) single lead, 84 (61.8%) 2-lead, and 5 (3.7%) 3-lead systems.
RESULTS: At baseline ICV, 10 patients (7%) were found to have venous anomalies, including 8 patients with obstructive lesions, 1 patient with a persistent left superior vena cava, and 1 patient with double axillary vein. At 6 months, a new obstructive venous lesion had developed in a total of 19 (14%) patients, none of whom exhibited any local symptoms. Of these patients 14 (10%) had a stenosis (mean D(min) 4.6 mm and diameter 38% of baseline), and 5 (3.6%) had a complete venous occlusion. In most cases the new stenosis developed in a location where the vessel was narrowest at baseline. Clinical predictors for the development of stenosis were atrial fibrillation at baseline and biventricular PM implantation.
CONCLUSIONS: This is the first systematic study to quantify venous changes after PM or ICD implantation. Our study shows that venous anomalies rendering PM implantation difficult are not infrequent. The incidence of new venous obstruction was 14%. Atrial fibrillation and biventricular PM implantation were independent predictors of venous obstruction.

Entities:  

Mesh:

Year:  2007        PMID: 17338716     DOI: 10.1111/j.1540-8159.2007.00650.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  19 in total

1.  Incidence and predictors of subclavian vein obstruction following biventricular device implantation.

Authors:  Serkan Bulur; Ahmet Vural; Mehmet Yazıcı; Gökhan Ertaş; Hakan Özhan; Dilek Ural
Journal:  J Interv Card Electrophysiol       Date:  2010-10-02       Impact factor: 1.900

2.  Emergency department diagnosis of upper extremity deep venous thrombosis using bedside ultrasonography.

Authors:  Tony Rosen; Betty Chang; Martha Kaufman; Mary Soderman; David C Riley
Journal:  Crit Ultrasound J       Date:  2012-04-16

3.  Complex cardiac pacing in the setting of a district general hospital: procedural success and complications.

Authors:  Hazim Rahbi; Mohammed El-Din; Mohammad Salloum; Naeem Shaukat; Mohsin Farooq
Journal:  Heart Asia       Date:  2014-06-24

4.  Venous thrombosis after arthroscopic shoulder surgery: pacemaker leads as a possible cause: pacemaker leads as a possible cause.

Authors:  Demetris Delos; Scott A Rodeo
Journal:  HSS J       Date:  2011-08-20

5.  Internal Jugular Vein Complete Thrombosis After Dual Chamber Pacemaker Implant.

Authors:  Angelo Placci; Maria Mattioli; Maria Francesca Notarangelo; Gianluca Gonzi; Marco Zardini
Journal:  J Atr Fibrillation       Date:  2016-06-30

6.  Nanostim leadless pacemaker retrieval and simultaneous micra leadless pacemaker replacement: a single-center experience.

Authors:  Roshini S Asirvatham; Vaibhav R Vaidya; Trena M Thome; Paul A Friedman; Yong-Mei Cha
Journal:  J Interv Card Electrophysiol       Date:  2019-11-14       Impact factor: 1.900

7.  Implanted endocardial lead characteristics and risk of stroke or transient ischemic attack.

Authors:  Vaibhav R Vaidya; Christopher V DeSimone; Samuel J Asirvatham; Vishnu M Chandra; Amit Noheria; David O Hodge; Joshua P Slusser; Alejandro A Rabinstein; Paul A Friedman
Journal:  J Interv Card Electrophysiol       Date:  2014-04-27       Impact factor: 1.900

8.  Peripherally inserted central catheters and other intravascular devices: how safe are they for hemodialysis patients?

Authors:  Roman Shingarev; Michael Allon
Journal:  Am J Kidney Dis       Date:  2012-10       Impact factor: 8.860

Review 9.  Leadless Cardiac Pacemakers: Pacing Paradigm Change.

Authors:  Petr Neuzil; Vivek Y Reddy
Journal:  Curr Cardiol Rep       Date:  2015-08       Impact factor: 2.931

10.  Initial experience with the subcutaneous implantable cardioverter-defibrillator with the real costs of hospitalization analysis in a single Polish center.

Authors:  Marcin Grabowski; Monika Gawałko; Marcin Michalak; Andrzej Cacko; Michał Kowara; Agnieszka Kołodzińska; Łukasz Januszkiewicz; Paweł Balsam; Laura Vitali Serdoz; Joachim Winter; Grzegorz Opolski
Journal:  Cardiol J       Date:  2018-04-03       Impact factor: 2.737