Literature DB >> 17336224

Prostate volume contouring: a 3D analysis of segmentation using 3DTRUS, CT, and MR.

Wendy L Smith1, Craig Lewis, Glenn Bauman, George Rodrigues, David D'Souza, Robert Ash, Derek Ho, Varagur Venkatesan, Dónal Downey, Aaron Fenster.   

Abstract

PURPOSE: This study evaluated the reproducibility and modality differences of prostate contouring after brachytherapy implant using three-dimensional (3D) transrectal ultrasound (3DTRUS), T2-weighted magnetic resonance (MR), and computed tomography (CT) imaging. METHODS AND MATERIALS: Seven blinded observers contoured 10 patients' prostates, 30 day postimplant, on 3DTRUS, MR, and CT images to assess interobserver variability. Randomized images were contoured twice by each observer. We analyzed length and volume measurements and performed a 3D analysis of intra- and intermodality variation.
RESULTS: Average volume ratios were 1.16 for CT/MR, 0.90 for 3DTRUS/MR, and 1.30 for CT/3DTRUS. Overall contouring variability was largest for CT and similar for MR and 3DTRUS. The greatest variability of CT contours occurred at the posterior and anterior portions of the midgland. On MR, overall variability was smaller, with a maximum in the anterior region. On 3DTRUS, high variability occurred in anterior regions of the apex and base, whereas the prostate-rectum interface had the smallest variability. The shape of the prostate on MR was rounder, with the base and apex of similar size, whereas CT contours had broad, flat bases narrowing toward the apex. The average percent of surface area that was significantly different (95% confidence interval) for CT/MR was 4.1%; 3DTRUS/MR, 10.7%; and CT/3DTRUS, 6.3%. The larger variability of CT measurements made significant differences more difficult to detect.
CONCLUSIONS: The contouring of prostates on CT, MR, and 3DTRUS results in systematic differences in the locations of and variability in prostate boundary definition between modalities. MR and 3DTRUS display the smallest variability and the closest correspondence.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17336224     DOI: 10.1016/j.ijrobp.2006.11.027

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  54 in total

1.  Optoacoustic imaging of the prostate: development toward image-guided biopsy.

Authors:  Mohammad A Yaseen; Sergey A Ermilov; Hans-Peter Brecht; Richard Su; André Conjusteau; Matthew Fronheiser; Brent A Bell; Massoud Motamedi; Alexander A Oraevsky
Journal:  J Biomed Opt       Date:  2010 Mar-Apr       Impact factor: 3.170

2.  Critical discussion of evaluation parameters for inter-observer variability in target definition for radiation therapy.

Authors:  I Fotina; C Lütgendorf-Caucig; M Stock; R Pötter; D Georg
Journal:  Strahlenther Onkol       Date:  2012-01-27       Impact factor: 3.621

3.  Sequential Registration-Based Segmentation of the Prostate Gland in MR Image Volumes.

Authors:  Farzad Khalvati; Aryan Salmanpour; Shahryar Rahnamayan; Masoom A Haider; H R Tizhoosh
Journal:  J Digit Imaging       Date:  2016-04       Impact factor: 4.056

4.  A semiautomatic approach for prostate segmentation in MR images using local texture classification and statistical shape modeling.

Authors:  Maysam Shahedi; Martin Halicek; Qinmei Li; Lizhi Liu; Zhenfeng Zhang; Sadhna Verma; David M Schuster; Baowei Fei
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2019-03-08

Review 5.  MR-guided prostate interventions.

Authors:  Clare Tempany; Sarah Straus; Nobuhiko Hata; Steven Haker
Journal:  J Magn Reson Imaging       Date:  2008-02       Impact factor: 4.813

6.  Contemporary technique of intraoperative 3-dimensional ultrasonography-guided transperineal prostate cryotherapy.

Authors:  Venu Chalasani; Lori Gardi; Carlos H Martinez; Donal B Downey; Aaron Fenster; Joseph L Chin
Journal:  Can Urol Assoc J       Date:  2009-04       Impact factor: 1.862

7.  Clinical use of magnetic resonance imaging across the prostate brachytherapy workflow.

Authors:  P Blanchard; C Ménard; S J Frank
Journal:  Brachytherapy       Date:  2017-01-30       Impact factor: 2.362

Review 8.  Role of magnetic resonance imaging and magnetic resonance spectroscopic imaging before and after radiotherapy for prostate cancer.

Authors:  Antonio C Westphalen; David A McKenna; John Kurhanewicz; Fergus V Coakley
Journal:  J Endourol       Date:  2008-04       Impact factor: 2.942

9.  Reconstruction of brachytherapy seed positions and orientations from cone-beam CT x-ray projections via a novel iterative forward projection matching method.

Authors:  Damodar Pokhrel; Martin J Murphy; Dorin A Todor; Elisabeth Weiss; Jeffrey F Williamson
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

10.  Learning Non-rigid Deformations for Robust, Constrained Point-based Registration in Image-Guided MR-TRUS Prostate Intervention.

Authors:  John A Onofrey; Lawrence H Staib; Saradwata Sarkar; Rajesh Venkataraman; Cayce B Nawaf; Preston C Sprenkle; Xenophon Papademetris
Journal:  Med Image Anal       Date:  2017-04-12       Impact factor: 8.545

View more