Literature DB >> 17326360

Centration on the cornea vertex normal during hyperopic refractive photoablation using videokeratoscopy.

Diego de Ortueta1, Frank D Schreyger.   

Abstract

PURPOSE: To evaluate a method for centering the ablation in standard hyperopic LASIK using an excimer laser with a video-based eye tracker system.
METHODS: Results of 52 consecutive hyperopic eyes treated with the ESIRIS excimer laser were retrospectively reviewed. Ablation was shifted from the pupil center to the vertex normal of the cornea using pupillary offset measured with the Keratron Scout videokeratoscope. Outcomes were assessed 3 months postoperatively.
RESULTS: All eyes preoperatively had a nasally oriented vertex normal in relation to the pupil center. Three months postoperatively a refractive outcome of < 0.50 diopters of spherical equivalent was achieved in 94% (49/52) of eyes. No eye lost more than one line of best spectacle-corrected visual acuity.
CONCLUSIONS: Standard hyperopic LASIK with the ESIRIS laser system leads to good predictable efficacy and safety results when the ablation center is shifted to the cornea vertex normal based on videokeratoscopy data.

Entities:  

Mesh:

Year:  2007        PMID: 17326360     DOI: 10.3928/1081-597X-20070201-13

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  7 in total

1.  Dynamic distribution and correlation analysis of the angle kappa in myopia patients undergoing femtosecond-assisted laser in situ keratomileusis.

Authors:  Wen-Qing Deng; Yu-Hui Fang; Shu-Hua Lin; Ying-Jun Li
Journal:  Medicine (Baltimore)       Date:  2022-06-17       Impact factor: 1.817

2.  Centration of myopic refractive ablation: should we center treatment on the pupil or the visual axis?

Authors:  Gilad Rabina; Michael Mimouni; Jacqueline Slomovic; Nir Sorkin; Achia Nemet; Igor Kaiserman
Journal:  Lasers Med Sci       Date:  2021-06-29       Impact factor: 3.161

Review 3.  Clinical outcomes of corneal refractive surgery comparing centration on the corneal vertex with the pupil center: a meta-analysis.

Authors:  Jiamei Zhang; Yan Wang; Xiaoqin Chen; Wenjing Wu
Journal:  Int Ophthalmol       Date:  2020-07-15       Impact factor: 2.031

4.  Comparison of Wavelight Allegretto Eye-Q and Schwind Amaris 750S excimer laser in treatment of high astigmatism.

Authors:  Maja Bohac; Alma Biscevic; Mateja Koncarevic; Marija Anticic; Nikica Gabric; Sudi Patel
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-08-23       Impact factor: 3.117

5.  Centration axis in refractive surgery.

Authors:  Samuel Arba Mosquera; Shwetabh Verma; Colm McAlinden
Journal:  Eye Vis (Lond)       Date:  2015-02-24

Review 6.  Excimer laser 6(th) generation: state of the art and refractive surgical outcomes.

Authors:  Mohamed El Bahrawy; Jorge L Alió
Journal:  Eye Vis (Lond)       Date:  2015-03-01

Review 7.  Angle Kappa and its importance in refractive surgery.

Authors:  Majid Moshirfar; Ryan N Hoggan; Valliammai Muthappan
Journal:  Oman J Ophthalmol       Date:  2013-09
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.