Literature DB >> 17326186

Dynamically shimmed multivoxel 1H magnetic resonance spectroscopy and multislice magnetic resonance spectroscopic imaging of the human brain.

Kevin M Koch1, Laura I Sacolick, Terence W Nixon, Scott McIntyre, Douglas L Rothman, Robin A de Graaf.   

Abstract

In vivo multivoxel Magnetic Resonance Spectroscopy (MRS) and multislice Magnetic Resonance Spectroscopic Imaging (MRSI) are extremely susceptible to poor homogeneity of the static magnetic field. Existing room-temperature (RT) shim technology can adequately optimize the B(0) homogeneity of local volumes, such as single voxels. However, the widespread global homogeneity required for in vivo spectral acquisitions from multiple volumes in the human brain cannot be attained with a single RT shim setting. Dynamic shim updating (DSU) allows for use of local RT shim B(0) homogeneity compensation capabilities in a global fashion. Here, by updating first- and second-order shims on a voxel- and slice-specific basis using a pre-emphasized DSU system, we present multivoxel MRS and multislice MRSI of the human brain. These results demonstrate that DSU can increase multivoxel MRS acquisition capabilities and significantly improve the quality of multislice MRSI data.

Entities:  

Mesh:

Year:  2007        PMID: 17326186     DOI: 10.1002/mrm.21141

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  13 in total

1.  Degraded water suppression in small volume ¹H MRS due to localised shimming.

Authors:  Asa Carlsson; Maria Ljungberg; Göran Starck; Eva Forssell-Aronsson
Journal:  MAGMA       Date:  2011-01-06       Impact factor: 2.310

2.  High resolution NMR spectroscopy of rat brain in vivo through indirect zero-quantum-coherence detection.

Authors:  Robin A de Graaf; Douglas L Rothman; Kevin L Behar
Journal:  J Magn Reson       Date:  2007-06-10       Impact factor: 2.229

Review 3.  13C MRS studies of neuroenergetics and neurotransmitter cycling in humans.

Authors:  Douglas L Rothman; Henk M De Feyter; Robin A de Graaf; Graeme F Mason; Kevin L Behar
Journal:  NMR Biomed       Date:  2011-08-31       Impact factor: 4.044

4.  Selective proton-observed, carbon-edited (selPOCE) MRS method for measurement of glutamate and glutamine 13 C-labeling in the human frontal cortex.

Authors:  Henk M De Feyter; Raimund I Herzog; Bart R Steensma; Dennis W J Klomp; Peter B Brown; Graeme F Mason; Douglas L Rothman; Robin A de Graaf
Journal:  Magn Reson Med       Date:  2017-11-13       Impact factor: 4.668

5.  A 32-channel combined RF and B0 shim array for 3T brain imaging.

Authors:  Jason P Stockmann; Thomas Witzel; Boris Keil; Jonathan R Polimeni; Azma Mareyam; Cristen LaPierre; Kawin Setsompop; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2015-02-17       Impact factor: 4.668

Review 6.  In vivo B0 field shimming methods for MRI at 7T.

Authors:  Jason P Stockmann; Lawrence L Wald
Journal:  Neuroimage       Date:  2017-06-07       Impact factor: 6.556

7.  Dynamic B0 shimming at 7 T.

Authors:  Saikat Sengupta; E Brian Welch; Yansong Zhao; David Foxall; Piotr Starewicz; Adam W Anderson; John C Gore; Malcolm J Avison
Journal:  Magn Reson Imaging       Date:  2011-03-12       Impact factor: 2.546

8.  Parallel reconstruction in accelerated multivoxel MR spectroscopy.

Authors:  V O Boer; D W J Klomp; J Laterra; P B Barker
Journal:  Magn Reson Med       Date:  2015-06-17       Impact factor: 4.668

Review 9.  B0 magnetic field homogeneity and shimming for in vivo magnetic resonance spectroscopy.

Authors:  Christoph Juchem; Robin A de Graaf
Journal:  Anal Biochem       Date:  2016-06-09       Impact factor: 3.365

10.  Tactile and non-tactile sensory paradigms for fMRI and neurophysiologic studies in rodents.

Authors:  Basavaraju G Sanganahalli; Christopher J Bailey; Peter Herman; Fahmeed Hyder
Journal:  Methods Mol Biol       Date:  2009
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.