Literature DB >> 17325071

High-spatial-resolution whole-body MR angiography with high-acceleration parallel acquisition and 32-channel 3.0-T unit: initial experience.

Kambiz Nael1, Michael Fenchel, Mayil Krishnam, Gerhard Laub, J Paul Finn, Stefan G Ruehm.   

Abstract

The purpose of this HIPAA-compliant study was to prospectively evaluate the technical feasibility of a multistation high-spatial-resolution whole-body magnetic resonance (MR) angiography protocol in which high-acceleration parallel imaging (with acceleration factors of three and four) is performed with a 32-channel 3.0-T MR system. After institutional review board approval and written informed consent were obtained, 10 healthy volunteers (four men and six women aged 23-68 years) and four patients (two men and two women aged 56-79 years) suspected of having peripheral vascular disease underwent multistation whole-body contrast material-enhanced MR angiography. Use of multiarray surface coil technology and highly accelerated generalized autocalibrating partially parallel acquisition enabled the acquisition of isotropic high-spatial-resolution three-dimensional data sets for multiple stations. Two radiologists independently evaluated arterial image quality and presence of arterial stenoses. All examinations yielded good or excellent image quality. Interobserver agreement was excellent (kappa = 0.92; 95% confidence interval: 0.86, 0.96). Multistation whole-body MR angiography with high-acceleration parallel acquisition is feasible at 3.0 T. Further clinical studies combined with ongoing optimization of radiofrequency systems and coils seem warranted to advance the potential of this technology. (c) RSNA, 2007.

Entities:  

Mesh:

Year:  2007        PMID: 17325071     DOI: 10.1148/radiol.2423060135

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  13 in total

1.  Automated quantification of carotid artery stenosis on contrast-enhanced MRA data using a deformable vascular tube model.

Authors:  Avan Suinesiaputra; Patrick J H de Koning; Elena Zudilova-Seinstra; Johan H C Reiber; Rob J van der Geest
Journal:  Int J Cardiovasc Imaging       Date:  2011-12-09       Impact factor: 2.357

Review 2.  Whole-Body MRA.

Authors:  Harald Kramer; Harald H Quick; Bernd Tombach; Stefan O Schoenberg; Joerg Barkhausen
Journal:  Eur Radiol       Date:  2008-05-20       Impact factor: 5.315

3.  Recent advances in 3D time-resolved contrast-enhanced MR angiography.

Authors:  Stephen J Riederer; Clifton R Haider; Eric A Borisch; Paul T Weavers; Phillip M Young
Journal:  J Magn Reson Imaging       Date:  2015-06-01       Impact factor: 4.813

4.  Time-resolved bolus-chase MR angiography with real-time triggering of table motion.

Authors:  Casey P Johnson; Clifton R Haider; Eric A Borisch; James F Glockner; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

5.  [Prognostic value of cardiovascular MRI in diabetics].

Authors:  C L Schlett; R C Bertheau; H-U Kauczor; S Weckbach
Journal:  Radiologe       Date:  2015-04       Impact factor: 0.635

6.  Time-resolved dual-station calf-foot three-dimensional bolus chase MR angiography with fluoroscopic tracking.

Authors:  Casey P Johnson; Eric A Borisch; James F Glockner; Phillip M Young; Stephen J Riederer
Journal:  J Magn Reson Imaging       Date:  2012-06-29       Impact factor: 4.813

7.  Vascular masking for improved unfolding in 2D SENSE-accelerated 3D contrast-enhanced MR angiography.

Authors:  Eric G Stinson; Eric A Borisch; Casey P Johnson; Joshua D Trzasko; Phillip M Young; Stephen J Riederer
Journal:  J Magn Reson Imaging       Date:  2013-07-29       Impact factor: 4.813

8.  Improved receiver arrays and optimized parallel imaging accelerations applied to time-resolved 3D fluoroscopically tracked peripheral runoff CE-MRA.

Authors:  Paul T Weavers; Eric A Borisch; Tom C Hulshizer; Phillip J Rossman; Phillip M Young; Casey P Johnson; Jessica McKay; Christopher C Cline; Stephen J Riederer
Journal:  Magn Reson Imaging       Date:  2015-10-31       Impact factor: 2.546

Review 9.  Whole-body magnetic resonance angiography at 3.0 Tesla.

Authors:  Michael Fenchel; Kambiz Nael; Achim Seeger; Ulrich Kramer; Roya Saleh; Stephan Miller
Journal:  Eur Radiol       Date:  2008-02-15       Impact factor: 7.034

10.  Technical assessment of whole body angiography and cardiac function within a single MRI examination.

Authors:  S J Gandy; M Lambert; J J F Belch; I D Cavin; E Crowe; R Littleford; J A Macfarlane; S Z Matthew; P Martin; R S Nicholas; A D Struthers; F Sullivan; S A Waugh; R D White; J R Weir-McCall; J G Houston
Journal:  Clin Radiol       Date:  2015-03-16       Impact factor: 2.350

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.