Literature DB >> 17323731

The influence of interimplant distance and attachment type on the retention characteristics of mandibular overdentures on 2 implants: initial retention values.

George Michelinakis1, Craig W Barclay, Phillip W Smith.   

Abstract

PURPOSE: This in vitro study aimed to investigate the influence of (1) the interimplant distance and (2) the type of attachment on the retention of mandibular overdentures on 2 implants.
MATERIALS AND METHODS: Three stone casts were fabricated, each with 2 implant analogues embedded at distances of 19, 23, and 29 mm apart. Three different interchangeable mandibular overdenture attachments were secured onto the analogues: Hader bars, ball abutments, and stainless steel keepers for new generation neodymium-iron-boron magnets. In total, 45 groups of paired attachments were tested for initial vertical peak tensile load at the 3 interimplant distances.
RESULTS: Interimplant (interclip) distance played a significant role only in the retention produced by the Hader bar/red clip configuration. At 19 and 23 mm, the ball/socket attachments were statistically more retentive than the yellow clips, white clips, and magnets, but not compared to the red clips. At 29 mm, the ball abutments showed statistical superiority compared with all other attachments. Mean clinical intercanine distance for conventional full dentures was 22.88 mm.
CONCLUSION: Interimplant distance can affect the initial retention of mandibular overdentures on 2 implants depending on the type of attachment used. For a predetermined interimplant distance, attachment performance varies greatly.

Entities:  

Mesh:

Year:  2006        PMID: 17323731

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  9 in total

1.  Stud attachments for the mandibular implant-retained overdentures: Prosthetic complications. A literature review.

Authors:  Elie E Daou
Journal:  Saudi Dent J       Date:  2013-02-06

2.  A finite element analysis of stress distribution in the bone, around the implant supporting a mandibular overdenture with ball/o ring and magnetic attachment.

Authors:  Jins John; V Rangarajan; Ravindra C Savadi; K S Satheesh Kumar; Preeti Satheesh Kumar
Journal:  J Indian Prosthodont Soc       Date:  2012-03-09

3.  The Effect of Number and Distribution of Mini Dental Implants on Overdenture Stability: An In Vitro Study.

Authors:  Rafif Alshenaiber; Craig Barclay; Nick Silikas
Journal:  Materials (Basel)       Date:  2022-04-20       Impact factor: 3.748

4.  The effect of inter-implant distance on retention and resistance to dislodging forces for mandibular implant-tissue-supported overdentures.

Authors:  Farhad Tabatabaian; Abolfazl Saboury; Zahra Sadat Sobhani; Vicki C Petropoulos
Journal:  J Dent (Tehran)       Date:  2014-09-30

5.  Effect of Implant Location on Palateless Complete Overdenture Retention: an In Vitro Study.

Authors:  Nesma El-Amier; Ehab Elsaih; Mona Gibreel; Hassan El-Motaiam
Journal:  J Oral Maxillofac Res       Date:  2018-09-30

6.  Clinical evaluation of inter-implant distance influence on the wear characteristics of low-profile stud attachments used in mandibular implant‑retained overdentures.

Authors:  Nesreen El Mekawy; Mohamed-Yosry Elhawary
Journal:  J Clin Exp Dent       Date:  2019-01-01

7.  Effect of Various Retentive Element Materials on Retention of Mandibular Implant-Retained Overdentures.

Authors:  Atitiya Chindarungruangrat; Trinuch Eiampongpaiboon; Bundhit Jirajariyavej
Journal:  Molecules       Date:  2022-06-19       Impact factor: 4.927

8.  A Comparison of Biomechanical Properties of Implant-Retained Overdenture Based on Precision Attachment Type.

Authors:  Małgorzata Idzior-Haufa; Agnieszka A Pilarska; Wiesław Hędzelek; Piotr Boniecki; Krzysztof Pilarski; Barbara Dorocka-Bobkowska
Journal:  Materials (Basel)       Date:  2021-05-17       Impact factor: 3.623

9.  Effect of bar cross-section and female housing material on retention of mandibular implant bar overdentures: A comparative in vitro study.

Authors:  Elsayed A Abdel-Khalek; Abdullah M Ibrahim
Journal:  J Indian Prosthodont Soc       Date:  2017 Oct-Dec
  9 in total