Literature DB >> 1732356

Quantification of left ventricular performance during transient coronary occlusion at various anatomic sites in humans: a study using tantalum-178 and a multiwire gamma camera.

M S Verani1, J L Lacy, G W Guidry, S Nishimura, J J Mahmarian, T Athanasoulis, R Roberts.   

Abstract

To study the functional significance of transient coronary occlusion on systolic and diastolic left ventricular function relative to the anatomic site of occlusion, first-pass radionuclide angiography with a mobile multiwire gamma camera using tantalum-178 (dose activity less than or equal to 84 mCi/elution) was performed in 46 patients undergoing balloon coronary angioplasty. First-pass images were acquired immediately before angioplasty and during the last 30 s of a 60-s balloon inflation in 23 left anterior descending arteries, 18 right coronary arteries, 8 circumflex arteries and 3 diagonal coronary arteries. Occlusion of the left anterior descending artery resulted in significant decreases in left ventricular ejection fraction (54.6 +/- 12.7% to 32.3 +/- 10.6%, p = 0.0001) and peak filling rate (2.48 +/- 0.68 to 1.75 +/- 0.64 end-diastolic volumes/s, p = 0.0001), accompanied by severe abnormalities in regional function and left ventricular dilation. Right coronary artery occlusion caused inferior hypokinesia, but did not significantly change left ventricular ejection fraction (48.5 +/- 12.4% vs. 45.8 +/- 12.5%, p = NS) or peak filling rate (2.05 +/- 0.81 vs. 2.09 +/- 0.81 end-diastolic volumes/s, p = NS). Circumflex artery occlusion resulted in mild wall motion deterioration and a borderline decrease in ejection fraction (54.7 +/- 11.4% to 50.5 +/- 12%, p = 0.057). Diagonal artery occlusion did not cause significant changes in left ventricular ejection fraction or filling rate. The decrease in left ventricular ejection fraction during coronary occlusion was 9 +/- 25% and 27 +/- 22%, respectively, in those arteries with and without collateral supply (p = 0.052). These data provide strong evidence for the critical importance of the left anterior descending artery and the secondary role of the other coronary arteries in maintaining global systolic and diastolic left ventricular function and suggest a protective role of collateral vessels during coronary occlusion.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1732356     DOI: 10.1016/0735-1097(92)90482-3

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  10 in total

Review 1.  Measurement of ventricular function with scintigraphic techniques: part I-imaging hardware, radiopharmaceuticals, and first-pass radionuclide angiography.

Authors:  Kim A Williams
Journal:  J Nucl Cardiol       Date:  2005 Jan-Feb       Impact factor: 5.952

2.  First-pass radionuclide angiography.

Authors:  John D Friedman; Daniel S Berman; Salvador Borges-Neto; Sean W Hayes; Lynne L Johnson; Kenneth J Nichols; Robert A Pagnanelli; Steven C Port
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

Review 3.  Ninth annual Mario S. Verani memorial lecture : testing our tests: the evidence bar is rising. Regulatory considerations in the development of cardiac imaging agents.

Authors:  James E Udelson
Journal:  J Nucl Cardiol       Date:  2011-08       Impact factor: 5.952

Review 4.  Nuclear medicine at the crossroads.

Authors:  H W Strauss
Journal:  Eur J Nucl Med       Date:  1996-06

5.  Imaging guidelines for nuclear cardiology procedures. American Society of Nuclear Cardiology. First-pass radionuclide angiography (FPRNA).

Authors: 
Journal:  J Nucl Cardiol       Date:  1996 May-Jun       Impact factor: 5.952

6.  Assessment of left ventricular function during upright treadmill exercise with tantalum 178 and multiwire gamma camera.

Authors:  Jaekyeong Heo; Thein Htay; Deval Mehta; Liang Sun; Jeffrey Lacy; Ami E Iskandrian
Journal:  J Nucl Cardiol       Date:  2005 Sep-Oct       Impact factor: 5.952

Review 7.  Wire chambers revisited.

Authors:  R J Ott
Journal:  Eur J Nucl Med       Date:  1993-04

8.  Development and validation of a novel technique for murine first-pass radionuclide angiography with a fast multiwire camera and tantalum 178.

Authors:  J L Lacy; T Nanavaty; D Dai; N Nayak; N Haynes; C Martin
Journal:  J Nucl Cardiol       Date:  2001 Mar-Apr       Impact factor: 5.952

9.  Effects of altered left ventricular geometry on quantitative technetium 99m sestamibi defect size in humans: perfusion imaging during coronary angioplasty.

Authors:  H L Haronian; A J Sinusas; M S Remetz; J J Brennan; H S Cabin; B L Zaret; F J Wackers
Journal:  J Nucl Cardiol       Date:  1994 Mar-Apr       Impact factor: 5.952

10.  Diastolic aortic pressure rise during percutaneous transluminal coronary angioplasty: an index of left ventricular systolic dysfunction.

Authors:  I A Paraskevaidis; Z S Kyriakides; A K Kassimatis; T P Apostolou; G K Kalopisis; D T Kremastinos
Journal:  Br Heart J       Date:  1995-09
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.