Literature DB >> 17322433

Use of the reverse shoulder prosthesis for the treatment of failed hemiarthroplasty in patients with glenohumeral arthritis and rotator cuff deficiency.

J C Levy1, N Virani, D Pupello, M Frankle.   

Abstract

We report the use of the reverse shoulder prosthesis in the revision of a failed shoulder hemiarthroplasty in 19 shoulders in 18 patients (7 men, 11 women) with severe pain and loss of function. The primary procedure had been undertaken for glenohumeral arthritis associated with severe rotator cuff deficiency. Statistically significant improvements were seen in pain and functional outcome. After a mean follow-up of 44 months (24 to 89), mean forward flexion improved by 26.4 degrees and mean abduction improved by 35 degrees . There were six prosthesis-related complications in six shoulders (32%), five of which had severe bone loss of the glenoid, proximal humerus or both. Three shoulders (16%) had non-prosthesis related complications. The use of the reverse shoulder prosthesis provides improvement in pain and function for patients with failure of a hemiarthroplasty for glenohumeral arthritis and rotator cuff deficiency. However, high rates of complications were associated with glenoid and proximal humeral bone loss.

Entities:  

Mesh:

Year:  2007        PMID: 17322433     DOI: 10.1302/0301-620X.89B2.18161

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  61 in total

Review 1.  Reverse total shoulder arthroplasty-from the most to the least common complication.

Authors:  Mazda Farshad; Christian Gerber
Journal:  Int Orthop       Date:  2010-09-25       Impact factor: 3.075

2.  Anatomic shoulder arthroplasty: an update on indications, technique, results and complication rates.

Authors:  Lorenzo Mattei; Stefano Mortera; Chiara Arrigoni; Filippo Castoldi
Journal:  Joints       Date:  2015-11-03

3.  Primary Monoblock Inset Reverse Shoulder Arthroplasty Resulted in Decreased Pain and Improved Function.

Authors:  Jonathan C Levy; Derek Berglund; Rushabh Vakharia; Paul DeVito; Dimitri S Tahal; Dragomir Mijc; Bijan Ameri
Journal:  Clin Orthop Relat Res       Date:  2019-09       Impact factor: 4.176

4.  Reverse shoulder prosthesis as revision surgery after fractures of the proximal humerus, treated initially by internal fixation or hemiarthroplasty.

Authors:  Nicola Lollino; Paolo Paladini; Fabrizio Campi; Giovanni Merolla; Paolo Rossi; Giuseppe Porcellini
Journal:  Chir Organi Mov       Date:  2009-04

Review 5.  How reverse shoulder arthroplasty works.

Authors:  Matthew Walker; Jordan Brooks; Matthew Willis; Mark Frankle
Journal:  Clin Orthop Relat Res       Date:  2011-09       Impact factor: 4.176

6.  Reverse shoulder arthroplasty as a salvage procedure for failed conventional shoulder replacement due to cuff failure--midterm results.

Authors:  Matthias P Flury; Philipp Frey; Joerg Goldhahn; Hans-Kaspar Schwyzer; Beat R Simmen
Journal:  Int Orthop       Date:  2010-03-14       Impact factor: 3.075

7.  Decision-making in massive rotator cuff tear.

Authors:  André Thès; Philippe Hardy; Klaus Bak
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-12-11       Impact factor: 4.342

Review 8.  Complications with reverse total shoulder arthroplasty and recent evolutions.

Authors:  Marius M Scarlat
Journal:  Int Orthop       Date:  2013-03-03       Impact factor: 3.075

9.  A convertible shoulder system: is it useful in total shoulder arthroplasty revisions?

Authors:  Jean Kany; Thomas Amouyel; Olivier Flamand; Denis Katz; Philippe Valenti
Journal:  Int Orthop       Date:  2014-10-16       Impact factor: 3.075

10.  Cyanoacrylate microbial sealant may reduce the prevalence of positive cultures in revision shoulder arthroplasty.

Authors:  Adam J Lorenzetti; Montri D Wongworawat; Christopher M Jobe; Wesley P Phipatanakul
Journal:  Clin Orthop Relat Res       Date:  2013-10       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.