Literature DB >> 17321392

Tilt and decentration of intraocular lenses in vivo from Purkinje and Scheimpflug imaging. Validation study.

Alberto de Castro1, Patricia Rosales, Susana Marcos.   

Abstract

PURPOSE: To measure tilt and decentration of intraocular lenses (IOLs) with Scheimpflug and Purkinje imaging systems in physical model eyes with known amounts of tilt and decentration and patients.
SETTING: Instituto de Optica Daza de Valdés, Consejo Superior de Investigaciones Científicas, Madrid, Spain.
METHODS: Measurements of IOL tilt and decentration were obtained using a commercial Scheimpflug system (Pentacam, Oculus), custom algorithms, and a custom-built Purkinje imaging apparatus. Twenty-five Scheimpflug images of the anterior segment of the eye were obtained at different meridians. Custom algorithms were used to process the images (correction of geometrical distortion, edge detection, and curve fittings). Intraocular lens tilt and decentration were estimated by fitting sinusoidal functions to the projections of the pupillary axis and IOL axis in each image. The Purkinje imaging system captures pupil images showing reflections of light from the anterior corneal surface and anterior and posterior lens surfaces. Custom algorithms were used to detect the Purkinje image locations and estimate IOL tilt and decentration based on a linear system equation and computer eye models with individual biometry. Both methods were validated with a physical model eye in which IOL tilt and decentration can be set nominally. Twenty-one eyes of 12 patients with IOLs were measured with both systems.
RESULTS: Measurements of the physical model eye showed an absolute discrepancy between nominal and measured values of 0.279 degree (Purkinje) and 0.243 degree (Scheimpflug) for tilt and 0.094 mm (Purkinje) and 0.228 mm (Scheimpflug) for decentration. In patients, the mean tilt was less than 2.6 degrees and the mean decentration less than 0.4 mm. Both techniques showed mirror symmetry between right eyes and left eyes for tilt around the vertical axis and for decentration in the horizontal axis.
CONCLUSIONS: Both systems showed high reproducibility. Validation experiments on physical model eyes showed slightly higher accuracy with the Purkinje method than the Scheimpflug imaging method. Horizontal measurements of patients with both techniques were highly correlated. The IOLs tended to be tilted and decentered nasally in most patients.

Entities:  

Mesh:

Year:  2007        PMID: 17321392     DOI: 10.1016/j.jcrs.2006.10.054

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  27 in total

1.  Changes in crystalline lens radii of curvature and lens tilt and decentration during dynamic accommodation in rhesus monkeys.

Authors:  Patricia Rosales; Mark Wendt; Susana Marcos; Adrian Glasser
Journal:  J Vis       Date:  2008-01-28       Impact factor: 2.240

2.  [Purkinje images in slit lamp videography : Video article].

Authors:  M-M Gellrich; C Kandzia
Journal:  Ophthalmologe       Date:  2016-09       Impact factor: 1.059

3.  Comparison of long-term decentration and tilt in two types of multifocal intraocular lenses with OPD-Scan III aberrometer.

Authors:  Wenwen He; Xiaodi Qiu; Shaohua Zhang; Yu Du; Yinglei Zhang; Yi Lu; Xiangjia Zhu
Journal:  Eye (Lond)       Date:  2018-03-09       Impact factor: 3.775

4.  Optical coherence tomography-based deep learning algorithm for quantification of the location of the intraocular lens.

Authors:  Chen Xin; Gui-Bin Bian; Haojie Zhang; Weipeng Liu; Zhe Dong
Journal:  Ann Transl Med       Date:  2020-07

Review 5.  Opto-Mechanical Eye Models, a Review on Human Vision Applications and Perspectives for Use in Industry.

Authors:  André Rino Amorim; Boris Bret; José M González-Méijome
Journal:  Sensors (Basel)       Date:  2022-10-10       Impact factor: 3.847

6.  Effects of tilt and decentration of Visian Implantable Collamer Lens (ICL V4c) on visual quality: an observational study.

Authors:  Lingling Niu; Zhe Zhang; Huamao Miao; Jing Zhao; Meiyan Li; Ji C He; Peijun Yao; Xingtao Zhou
Journal:  BMC Ophthalmol       Date:  2022-07-05       Impact factor: 2.086

7.  Stability of Various Types of Aspheric Intraocular Lenses After Implantation: A One-Year Retrospective Study.

Authors:  Yuan Ning; Yushuang Shao; Jiangyue Zhao; Jinsong Zhang; Mingwu Wang; Yu Qin
Journal:  Int J Gen Med       Date:  2021-06-01

8.  In vivo human crystalline lens topography.

Authors:  Sergio Ortiz; Pablo Pérez-Merino; Enrique Gambra; Alberto de Castro; Susana Marcos
Journal:  Biomed Opt Express       Date:  2012-09-12       Impact factor: 3.732

9.  Full OCT anterior segment biometry: an application in cataract surgery.

Authors:  Sergio Ortiz; Pablo Pérez-Merino; Sonia Durán; Miriam Velasco-Ocana; Judith Birkenfeld; Alberto de Castro; Ignacio Jiménez-Alfaro; Susana Marcos
Journal:  Biomed Opt Express       Date:  2013-01-31       Impact factor: 3.732

10.  IOL tilt and decentration estimation from 3 dimensional reconstruction of OCT image.

Authors:  Xiaogang Wang; Jing Dong; Xiaoliang Wang; Qiang Wu
Journal:  PLoS One       Date:  2013-03-15       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.