Literature DB >> 17318998

Stabilization of the coronary sinus electrode position with coronary stent implantation to prevent and treat dislocation.

Szabolcs Szilagyi1, Bela Merkely, Attila Roka, Endre Zima, Gabor Fulop, Valentina Kutyifa, Gabor Szucs, David Becker, Astrid Apor, Laszlo Geller.   

Abstract

INTRODUCTION: Coronary sinus (CS) leads used for cardiac resynchronization have undergone development in the last years. However, dislocation rate remained high (5-9%). The aim of this study was to investigate the effectiveness and safety of stent implantation in a CS side vein to stabilize the left ventricular lead position after postoperative or intraoperative dislocation of the electrode. METHODS AND
RESULTS: Thirty-six patients (age: 64 +/- 9.7 years, 19 primary, 17 ischemic cardiomyopathy, NYHA class III: 30, IV: 6) were treated with stenting. The procedure was performed because of postoperative dislocation in seven patients, while dislocation was observed during the implantation in 29 cases. The electrode was repositioned into the desired position and a bare metal coronary stent was introduced via another guide wire. The stent was deposited at 5- to 15-mm proximal to the tip of the electrode with a pressure of 6 to 14 atmospheres. Control angiography showed no blood flow compromise in any of the side branches or in the coronary sinus. Control echocardiography did not show pericardial effusion due to stenting. During follow-up (11.5 +/- 5.5, 2-23 months), left ventricular pacing threshold increased from 2.2 to 5.6 V in one patient, but dislocation was not found by fluoroscopy. Clinically important pacing threshold increase was not detected in the other cases. Impedance measurements did not suggest lead insulation failure.
CONCLUSION: Stent implantation to stabilize the left ventricular lead position seems to be a useful and safe procedure in the treatment of patients with complicated coronary sinus anatomy or lead instability.

Entities:  

Mesh:

Year:  2007        PMID: 17318998     DOI: 10.1111/j.1540-8167.2007.00722.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  7 in total

1.  Early coronary vein stenosis after cardiac resynchronization therapy.

Authors:  D Aras; O Ozeke; F A Baskok; S Avci; M Cebeci; B Sensoy; K Acikgoz; S Topaloglu
Journal:  Herz       Date:  2013-10-25       Impact factor: 1.443

2.  Electrocardiographic clues to identify nonresponders to cardiac resynchronization therapy.

Authors:  Firas H El Sabbagh; Osler Jay J Guzon; Martin A Alpert; Greg C Flaker
Journal:  Ann Noninvasive Electrocardiol       Date:  2010-10       Impact factor: 1.468

3.  Three-dimensional electroanatomic mapping of the coronary veins during cardiac resynchronization therapy implant: feasibility and possible applications.

Authors:  Imran Niazi; Kyungmoo Ryu; Richard Hood; Indrajit Choudhuri; Masood Akhtar
Journal:  J Interv Card Electrophysiol       Date:  2014-07-09       Impact factor: 1.900

4.  Longer right to left ventricular activation delay at cardiac resynchronization therapy implantation is associated with improved clinical outcome in left bundle branch block patients.

Authors:  Annamaria Kosztin; Valentina Kutyifa; Vivien Klaudia Nagy; Laszlo Geller; Endre Zima; Levente Molnar; Szabolcs Szilagyi; Emin Evren Ozcan; Gabor Szeplaki; Bela Merkely
Journal:  Europace       Date:  2015-06-27       Impact factor: 5.214

5.  Overcoming an impossible anatomy with a novel left ventricular active fixation lead in the coronary sinus: A case report.

Authors:  Gabriele Giannola; Riccardo Torcivia; Riccardo Airò Farulla; Joeri Heynens
Journal:  HeartRhythm Case Rep       Date:  2015-02-12

6.  Long-term single-centre large volume experience with transseptal endocardial left ventricular lead implantation.

Authors:  László Gellér; Zoltán Salló; Levente Molnár; Tamás Tahin; Emin Evren Özcan; Valentina Kutyifa; István Osztheimer; Szabolcs Szilágyi; Nándor Szegedi; Pál Ábrahám; Astrid Apor; Klaudia Vivien Nagy; Annamária Kosztin; Dávid Becker; Szilvia Herczeg; Endre Zima; Béla Merkely
Journal:  Europace       Date:  2019-08-01       Impact factor: 5.214

7.  New left ventricular active fixation lead: The experience of lead extraction.

Authors:  Matteo Ziacchi; Igor Diemberger; Cristian Martignani; Giuseppe Boriani; Mauro Biffi
Journal:  Indian Heart J       Date:  2015-12-18
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.