Literature DB >> 17315763

Wear and biological activity of highly crosslinked polyethylene in the hip under low serum protein concentrations.

A L Galvin1, J L Tipper, L M Jennings, M H Stone, Z M Jin, E Ingham, I Fisher.   

Abstract

Crosslinked ultra-high molecular weight polyethylene (UHMWPE) has been developed and introduced into clinical practice in order to reduce wear in the hip. Zero wear of highly crosslinked UHMWPE in vitro has been reported by some groups using lubricants with high concentrations of serum proteins in hip simulators. In contrast, some clinical studies have reported finite wear rates. The aim of this study was to compare the wear rates, wear surfaces, and wear debris produced by UHMWPE with different levels of crosslinking in a hip joint simulator, with lower, more physiologically relevant concentrations of protein in the lubricant. The UHMWPEs were tested in the Leeds ProSim hip joint simulator against cobalt-chromium (CoCr) femoral heads. The wear particles were isolated and imaged using a field emission gun scanning electron microscope (FEGSEM) at high resolution. The highly crosslinked UHMWPEs had significantly lower wear volumes than the non-crosslinked UHMWPEs. No significant difference was found in the percentage number and percentage volume of the particles in different size ranges from any of the materials. They had similar values of specific biological activity. The functional biological activity (FBA), which takes into account the wear volume and specific biological activity, showed that the highly crosslinked UHMWPEs had lower FBAs due to their lower wear volume.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17315763     DOI: 10.1243/09544119JEIM99

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  12 in total

Review 1.  Mediators of the inflammatory response to joint replacement devices.

Authors:  Neil Cobelli; Brian Scharf; Giovanna M Crisi; John Hardin; Laura Santambrogio
Journal:  Nat Rev Rheumatol       Date:  2011-09-06       Impact factor: 20.543

2.  Characteristics of highly cross-linked polyethylene wear debris in vivo.

Authors:  Ryan M Baxter; Daniel W MacDonald; Steven M Kurtz; Marla J Steinbeck
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2013-02-22       Impact factor: 3.368

3.  Otto Aufranc Award: Crosslinking Reduces THA Wear, Osteolysis, and Revision Rates at 15-year Followup Compared With Noncrosslinked Polyethylene.

Authors:  Robert H Hopper; Henry Ho; Supatra Sritulanondha; Ann C Williams; Charles A Engh
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

4.  Inhibition of Sulfate Reduction and Cell Division by Desulfovibrio desulfuricans Coated in Palladium Metal.

Authors:  Robert J Barnes; Stephen P Voegtlin; Shiv R Naik; Renessa Gomes; Casey R J Hubert; Stephen R Larter; Steven L Bryant
Journal:  Appl Environ Microbiol       Date:  2022-05-31       Impact factor: 5.005

5.  Nanostructured diamond coatings for orthopaedic applications.

Authors:  S A Catledge; V Thomas; Y K Vohra
Journal:  Woodhead Publ Ser Biomater       Date:  2013

6.  Simultaneous Characterization of Implant Wear and Tribocorrosion Debris within Its Corresponding Tissue Response Using Infrared Chemical Imaging.

Authors:  Songyun Liu; Deborah J Hall; Craig J Della Valle; Michael J Walsh; Joshua J Jacobs; Robin Pourzal
Journal:  Biotribology (Oxf)       Date:  2021-02-19

7.  Effect of motion inputs on the wear prediction of artificial hip joints.

Authors:  Feng Liu; John Fisher; Zhongmin Jin
Journal:  Tribol Int       Date:  2013-07       Impact factor: 4.872

Review 8.  Ultra-High Molecular Weight Polyethylene: Influence of the Chemical, Physical and Mechanical Properties on the Wear Behavior. A Review.

Authors:  Pierangiola Bracco; Anuj Bellare; Alessandro Bistolfi; Saverio Affatato
Journal:  Materials (Basel)       Date:  2017-07-13       Impact factor: 3.623

9.  (iv) Enhancing the safety and reliability of joint replacement implants.

Authors:  Louise M Jennings; Mazen Al-Hajjar; Claire L Brockett; Sophie Williams; Joanne L Tipper; Eileen Ingham; John Fisher
Journal:  Orthop Trauma       Date:  2012-08

Review 10.  Immunological Responses to Total Hip Arthroplasty.

Authors:  Kenny Man; Lin-Hua Jiang; Richard Foster; Xuebin B Yang
Journal:  J Funct Biomater       Date:  2017-08-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.