Literature DB >> 17301467

Regional blood flow analysis and its relationship with arterial branch lengths and lumen volume in the coronary arterial tree.

Sabee Molloi1, Jerry T Wong.   

Abstract

The limitations of visually assessing coronary artery disease are well known. These limitations are particularly important in intermediate coronary lesions (30-70% diameter stenosis) where it is difficult to determine whether a particular lesion is the cause of ischaemia. Therefore, a functional measure of stenosis severity is needed. The purpose of this study is to determine whether the expected maximum coronary blood flow in an arterial tree is predictable from its sum of arterial branch lengths or lumen volume. Using a computer model of a porcine coronary artery tree, an analysis of blood flow distribution was conducted through a network of millions of vessels that included the entire coronary artery tree down to the first capillary branch. The flow simulation results show that there is a linear relationship between coronary blood flow and the sum of its arterial branch lengths. This relationship holds over the entire arterial tree. The flow simulation results also indicate that there is a 3/4 power relation between coronary blood flow (Q) and the sum of its arterial lumen volume (V). Moreover, there is a linear relationship between normalized Q and normalized V raised to a power of 3/4 over the entire arterial tree. These results indicate that measured arterial branch lengths or lumen volumes can be used to predict the expected maximum blood flow in an arterial tree. This theoretical maximum blood flow, in conjunction with an angiographically measured blood flow, can potentially be used to calculate fractional flow reserve based entirely on angiographic data.

Entities:  

Mesh:

Year:  2007        PMID: 17301467     DOI: 10.1088/0031-9155/52/5/018

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  An angiographic technique for coronary fractional flow reserve measurement: in vivo validation.

Authors:  Shigeho Takarada; Zhang Zhang; Sabee Molloi
Journal:  Int J Cardiovasc Imaging       Date:  2012-08-31       Impact factor: 2.357

2.  Quantification of fractional flow reserve based on angiographic image data.

Authors:  Jerry T Wong; Huy Le; William M Suh; David A Chalyan; Toufan Mehraien; Morton J Kern; Ghassan S Kassab; Sabee Molloi
Journal:  Int J Cardiovasc Imaging       Date:  2011-01-07       Impact factor: 2.357

3.  Estimation of coronary artery hyperemic blood flow based on arterial lumen volume using angiographic images.

Authors:  Sabee Molloi; David Chalyan; Huy Le; Jerry T Wong
Journal:  Int J Cardiovasc Imaging       Date:  2011-01-07       Impact factor: 2.357

4.  Topologic and Hemodynamic Characteristics of the Human Coronary Arterial Circulation.

Authors:  Janina C V Schwarz; Monique G J T B van Lier; Jeroen P H M van den Wijngaard; Maria Siebes; Ed VanBavel
Journal:  Front Physiol       Date:  2020-01-23       Impact factor: 4.566