Literature DB >> 1729005

Determinants of stress shielding: design versus materials versus interface.

D R Sumner1, J O Galante.   

Abstract

Experimental studies of cementless porous-coated total hip arthroplasty indicate that a critical design variable for femoral remodeling is stem stiffness. In the long term (two years) in the canine model, other variables, including the presence, type, and placement of the porous coating, did not significantly affect the pattern of bone remodeling when tested with metallic stems. The basic pattern of bone remodeling was characterized by proximal cortical atrophy, and distal cortical and medullary bone hypertrophy. In the short term (six months), the use of low-stiffness stems altered this pattern, leading to reduced proximal bone loss, increased proximal medullary bone hypertrophy, and no distal cortical hypertrophy, suggesting that stem stiffness had a profound effect on stress shielding.

Entities:  

Mesh:

Year:  1992        PMID: 1729005

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  42 in total

1.  Mid-term results of 155 patients treated with a collum femoris preserving (CFP) short stem prosthesis.

Authors:  Daniel Briem; Michael Schneider; Nicole Bogner; Nadine Botha; Matthias Gebauer; Thorsten Gehrke; Bernd Schwantes
Journal:  Int Orthop       Date:  2010-05-02       Impact factor: 3.075

2.  [Shaft lengthening in hip replacement: experimental studies on bending stiffness].

Authors:  K Burkhart; D Mehler; J Degreif; P M Rommens
Journal:  Unfallchirurg       Date:  2006-08       Impact factor: 1.000

Review 3.  Quantitative computer-assisted osteodensitometry in total hip arthroplasty.

Authors:  R P Pitto; L A Mueller; K Reilly; R Schmidt; J Munro
Journal:  Int Orthop       Date:  2006-10-17       Impact factor: 3.075

4.  Fixation and bone remodeling around a low stiffness stem in revision surgery.

Authors:  Johan Kärrholm; Reza Razaznejad
Journal:  Clin Orthop Relat Res       Date:  2008-01-10       Impact factor: 4.176

5.  Loss of tibial bone density in patients with rotating- or fixed-platform TKA.

Authors:  Jacob T Munro; Salil Pandit; Cameron G Walker; Mark Clatworthy; Rocco P Pitto
Journal:  Clin Orthop Relat Res       Date:  2009-03-26       Impact factor: 4.176

6.  Applications of finite element simulation in orthopedic and trauma surgery.

Authors:  Antonio Herrera; Elena Ibarz; José Cegoñino; Antonio Lobo-Escolar; Sergio Puértolas; Enrique López; Jesús Mateo; Luis Gracia
Journal:  World J Orthop       Date:  2012-04-18

7.  Long-term results and bone remodeling after THA with a short, metaphyseal-fitting anatomic cementless stem.

Authors:  Young-Hoo Kim; Jang-Won Park; Jun-Shik Kim; Jun-Seok Kang
Journal:  Clin Orthop Relat Res       Date:  2013-10-26       Impact factor: 4.176

Review 8.  In vitro biological outcome of laser application for modification or processing of titanium dental implants.

Authors:  Ahmed Hindy; Farzam Farahmand; Fahimeh Sadat Tabatabaei
Journal:  Lasers Med Sci       Date:  2017-04-27       Impact factor: 3.161

9.  Dual plating of humeral shaft fractures: orthogonal plates biomechanically outperform side-by-side plates.

Authors:  Victor Kosmopoulos; Arvind D Nana
Journal:  Clin Orthop Relat Res       Date:  2013-11-12       Impact factor: 4.176

10.  Numerical investigations on the strain-adaptive bone remodelling in the periprosthetic femur: influence of the boundary conditions.

Authors:  Bernd-Arno Behrens; Ingo Nolte; Patrick Wefstaedt; Christina Stukenborg-Colsman; Anas Bouguecha
Journal:  Biomed Eng Online       Date:  2009-04-16       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.