BACKGROUND: Although many mechanical devices are being developed for functional end-to-end anastomosis (FETEA), the best choice remains to be determined. The mechanical strength of each device is an important factor associated with anastomotic leakage. In turn, anastomotic patency is related to postoperative stenosis. This study examined the bursting pressure and circumference of several FETEAs.
METHODS: Young domestic pigs were used in this study. In experiment 1, a 10-cm segment of intestine was transected using an EndoGIA 60 blue, EndoGIA 60 green, or GIA 60 blue stapler, and the bursting pressure of each instrument's mechanical staple line was examined. In experiment 2, after FETEA had been created with EndoGIA 60 blue, the bursting sites were examined, and the bursting pressures of buttressed and nonbuttressed FETEA were measured and compared. In experiment 3, the circumference of FETEA was compared between the closed technique and reinforcement.
RESULTS: The bursting pressure of EndoGIA 60 blue was significantly higher than that of the other devices. When an anastomotic crotch was buttressed, the bursting pressure (44 +/- 13 mmHg) was significantly increased over that of the nonbuttressed FETEA (27.5 +/- 5.8 mmHg; p < 0.05). The circumference of FETEA using the wide technique (92.7 +/- 2.3 mm) was larger than that using the offset technique (55.7 +/- 5.8 mm).
CONCLUSIONS: The bursting pressure of the mechanical staple line using the EndoGIA 60 stapler was the strongest. Functional end-to-end anastomosis was stronger when created with buttress of an anastomotic crotch, and larger circumferences were created with the wide technique.

Entities:  

Mesh:

Year:  2007        PMID: 17285383     DOI: 10.1007/s00464-006-9131-6

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  15 in total

1.  Use of a cauterizing laparoscopic linear stapler in intestinal anastomosis.

Authors:  J M Hardacre; M Mendoza-Sagaon; K Murata; M A Talamini
Journal:  Surg Laparosc Endosc Percutan Tech       Date:  2000-06       Impact factor: 1.719

2.  Which technique, circular stapled anastomosis or double stapling anastomosis, provides the optimal size and shape of rectal anastomotic opening?

Authors:  S Sadahiro; T Kameya; H Iwase; K Ishikawa; T Suzuki; N Tokunaga; T Tajima; H Makuuchi
Journal:  J Surg Res       Date:  1999-09       Impact factor: 2.192

3.  Outcomes after laparoscopic Roux-en-Y gastric bypass for morbid obesity.

Authors:  P R Schauer; S Ikramuddin; W Gourash; R Ramanathan; J Luketich
Journal:  Ann Surg       Date:  2000-10       Impact factor: 12.969

4.  Comparison of automatic staplers in small bowel anastomoses.

Authors:  M K Bluett; D A Healy; G C Kalemeris; J P O'Leary
Journal:  South Med J       Date:  1986-06       Impact factor: 0.954

5.  A stapling instrument for end-to-end inverting anastomoses in the gastrointestinal tract.

Authors:  M M Ravitch; F M Steichen
Journal:  Ann Surg       Date:  1979-06       Impact factor: 12.969

6.  Mechanical sutures in surgery.

Authors:  F M Steichen; M M Ravitch
Journal:  Br J Surg       Date:  1973-03       Impact factor: 6.939

7.  The use of staplers in anatomical side-to-side and functional end-to-end enteroanastomoses.

Authors:  F M Steichen
Journal:  Surgery       Date:  1968-11       Impact factor: 3.982

8.  Anastomotic obstruction after stapled enteroanastomosis.

Authors:  R Ostericher; K P Lally; D M Barrett; M L Ritchey
Journal:  Surgery       Date:  1991-06       Impact factor: 3.982

9.  Laparoscopic gastric bypass, Roux-en-Y- 500 patients: technique and results, with 3-60 month follow-up.

Authors:  A C Wittgrove; G W Clark
Journal:  Obes Surg       Date:  2000-06       Impact factor: 4.129

10.  Comparison of different techniques of stapled bowel anastomoses in a canine model.

Authors:  M L Ritchey; K P Lally; R Ostericher
Journal:  Arch Surg       Date:  1993-12
View more
  10 in total

1.  The importance of precompression time for secure stapling with a linear stapler.

Authors:  Shinya Nakayama; Suguru Hasegawa; Satoshi Nagayama; Shigeru Kato; Koya Hida; Eiji Tanaka; Atsushi Itami; Hajime Kubo; Yoshiharu Sakai
Journal:  Surg Endosc       Date:  2010-12-24       Impact factor: 4.584

2.  Autobuttressing of colorectal anastomoses using a mesenteric flap.

Authors:  H M Mohan; D C Winter
Journal:  Updates Surg       Date:  2013-08-27

Review 3.  Reinforcement does not necessarily reduce the rate of staple line leaks after sleeve gastrectomy. A review of the literature and clinical experiences.

Authors:  Bo Chen; Andreas Kiriakopoulos; Dimitrios Tsakayannis; Mitchell S Wachtel; Dimitrios Linos; Eldo E Frezza
Journal:  Obes Surg       Date:  2008-09-16       Impact factor: 4.129

Review 4.  Technical controversies in laparoscopic sleeve gastrectomy.

Authors:  Manuel Ferrer-Márquez; Ricardo Belda-Lozano; Manuel Ferrer-Ayza
Journal:  Obes Surg       Date:  2012-01       Impact factor: 4.129

5.  Which Is the Safer Anastomotic Method for Colon Surgery? - Ten-year Results.

Authors:  Makoto Kosuge; Ken Eto; Ryosuke Hashizume; Mitsumasa Takeda; Kenta Tomori; Kai Neki; Norio Mitsumori; Katsuhiko Yanaga
Journal:  In Vivo       Date:  2017 Jul-Aug       Impact factor: 2.155

6.  Quantitative perfusion assessment of intestinal anastomoses in pigs treated with glucagon-like peptide 2.

Authors:  Nikolaj Nerup; Linea Landgrebe Ring; Rune Broni Strandby; Charlotte Egeland; Morten Bo Søndergaard Svendsen; Jane Preuss Hasselby; Gro Linno Willemoe; Bolette Hartmann; Lars Bo Svendsen; Michael Patrick Achiam
Journal:  Langenbecks Arch Surg       Date:  2018-10-18       Impact factor: 3.445

7.  Comparison of postoperative motility in hand-sewn end-to-end anastomosis and functional end-to-end anastomosis: an experimental study in conscious dogs.

Authors:  Yoshitaka Toyomasu; Erito Mochiki; Hiroyuki Ando; Mitsuhiro Yanai; Kyoichi Ogata; Yuichi Tabe; Tetsuro Ohno; Ryuusuke Aihara; Hiroyuki Kuwano
Journal:  Dig Dis Sci       Date:  2009-11-14       Impact factor: 3.199

8.  Use of bioabsorbable staple reinforcement material in side-to-side anastomoses: Suture line reinforcement of the weak point of the anastomosis.

Authors:  Masahiro Kimura; Yukio Terashita
Journal:  Ann Med Surg (Lond)       Date:  2016-01-23

9.  A comparison of extracorporeal side to side or end to side anastomosis following a laparoscopic right hemicolectomy for colon cancer.

Authors:  Ali Riaz Baqar; Simon Wilkins; Wei Chun Wang; Karen Oliva; Suellyn Centauri; Raymond Yap; Paul McMurrick
Journal:  ANZ J Surg       Date:  2022-04-11       Impact factor: 2.025

10.  Ileocolonic anastomosis after right hemicolectomy for colon cancer: functional end-to-end or end-to-side?

Authors:  Zheng Liu; Guiyu Wang; Ming Yang; Yinggang Chen; Dazhuang Miao; Shan Muhammad; Xishan Wang
Journal:  World J Surg Oncol       Date:  2014-10-07       Impact factor: 2.754

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.