Literature DB >> 17280537

BioMatrix Biolimus A9-eluting coronary stent: a next-generation drug-eluting stent for coronary artery disease.

Eberhard Grube1, Lutz Buellesfeld.   

Abstract

Drug-eluting stent technology consisting of a bare metal stent, carrier coating, bioactive drug and delivery system, offers an almost infinite range of possible device configurations. A growing understanding of the mechanisms of restenosis allows for the design of synergistic functions within these components, thus providing a basis for new and improved products. The BioMatrix stent (Biosensors Interventional Technologies Pte Ltd., Singapore) elutes the new sirolimus derivative Biolimus A9 from a biodegradable polylactic acid polymer. Biolimus A9 possesses enhanced anti-inflammatory and antiproliferative activity with an improved pharmacokinetic profile. Permanent polymer-carrier-based platforms may be associated with inflammation, late thrombosis and restenosis. The BioMatrix, with its asymmetric and abluminal coating, releases Biolimus A9 into the vessel wall while the polylactic acid polymer is resorbed by surrounding tissues. Clinical studies have demonstrated the BioMatrix to be well tolerated and effective, and it has now become the subject of an aggressive clinical program.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17280537     DOI: 10.1586/17434440.3.6.731

Source DB:  PubMed          Journal:  Expert Rev Med Devices        ISSN: 1743-4440            Impact factor:   3.166


  10 in total

1.  Drug-eluting stents.

Authors:  Xiaodong Ma; Tim Wu; Michael P Robich; Xingwei Wang; Hao Wu; Bryan Buchholz; Stephen McCarthy
Journal:  Int J Clin Exp Med       Date:  2010-07-15

2.  The pharmacokinetics of Biolimus A9 after elution from the BioMatrix II stent in patients with coronary artery disease: the Stealth PK Study.

Authors:  Miodrag C Ostojic; Zoran Perisic; Dragan Sagic; Robert Jung; Yan-Ling Zhang; Jamie Bendrick-Peart; Ronald Betts; Uwe Christians
Journal:  Eur J Clin Pharmacol       Date:  2010-10-09       Impact factor: 2.953

3.  In vitro study of dual drug-eluting stents with locally focused sirolimus and atorvastatin release.

Authors:  Svea Petersen; Janine Hussner; Thomas Reske; Niels Grabow; Volkmar Senz; Robert Begunk; Daniela Arbeiter; Heyo K Kroemer; Klaus-Peter Schmitz; Henriette E Meyer zu Schwabedissen; Katrin Sternberg
Journal:  J Mater Sci Mater Med       Date:  2013-07-12       Impact factor: 3.896

4.  Development and validation of a semi-automated assay for the highly sensitive quantification of Biolimus A9 in human whole blood using high-performance liquid chromatography-tandem mass spectrometry.

Authors:  Claudia Clavijo; Tobin Strom; Vanessa Moll; Ronald Betts; Yan Ling Zhang; Uwe Christians; Jamie Bendrick-Peart
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2009-08-21       Impact factor: 3.205

5.  The pharmacokinetics of Biolimus A9 after elution from the Nobori stent in patients with coronary artery disease: the NOBORI PK study.

Authors:  Miodrag Ostojic; Dragan Sagic; Robert Jung; Yan-Ling Zhang; Milan Nedeljkovic; Ljupco Mangovski; Sinisa Stojkovic; Dragan Debeljacki; Mirko Colic; Branko Beleslin; Bratislav Milosavljevic; Dejan Orlic; Dragan Topic; Nevena Karanovic; Dragica Paunovic; Uwe Christians
Journal:  Catheter Cardiovasc Interv       Date:  2008-12-01       Impact factor: 2.692

6.  A rapamycin derivative, biolimus, preferentially activates autophagy in vascular smooth muscle cells.

Authors:  Yerin Kim; Jun Kyu Park; Jun-Hyuk Seo; Hyun-Seung Ryu; Kyung Seob Lim; Myung Ho Jeong; Dong Hoon Kang; Sang Won Kang
Journal:  Sci Rep       Date:  2018-11-08       Impact factor: 4.379

7.  A First-in-Man Clinical Evaluation of Sirolimus and Ascorbic Acid-Eluting Stent Systems: a Multicenter, Subject-Blinded, Randomized Study.

Authors:  Young-Hyo Lim; Ji Hyun Youn; Soon-Jun Hong; Tae-Hoon Ahn; Junghan Yoon; Jun-Kyu Park; Hyo-Soo Kim
Journal:  Korean Circ J       Date:  2021-12       Impact factor: 3.243

Review 8.  Drug-eluting metallic stents in urology.

Authors:  Panagiotis S Kallidonis; Ioannis S Georgiopoulos; Iason D Kyriazis; Abdulrahman M Al-Aown; Evangelos N Liatsikos
Journal:  Indian J Urol       Date:  2014-01

9.  Histopathological Comparison among Biolimus, Zotarolimus and Everolimus-Eluting Stents in Porcine Coronary Restenosis Model.

Authors:  Kyung Seob Lim; Myung Ho Jeong; In Ho Bae; Dae Sung Park; Jong Min Kim; Jung Ha Kim; Dong Lyun Cho; Doo Sun Sim; Keun-Ho Park; Young Joon Hong; Youngkeun Ahn
Journal:  Korean Circ J       Date:  2013-11-30       Impact factor: 3.243

10.  Effectiveness and Safety of Biolimus A9™-Eluting stEnt in Patients with AcUTe Coronary sYndrome; A Multicenter, Observational Study (BEAUTY Study).

Authors:  Keun Ho Park; Myung Ho Jeong; Young Joon Hong; Youngkeun Ahn; Hyun Kuk Kim; Young Yub Koh; Doo Il Kim; Sang Wook Kim; Weon Kim; Seung Woon Rha; Jay Young Rhew; Jong Seon Park; Hun Sik Park; Jang Ho Bae; Jang Whan Bae; Seok Kyu Oh; Sung Yun Lee; Seung Wook Lee; Jae Hwan Lee; Sang Yeob Lim; Jang Hyun Cho; Kwang Soo Cha; Jai Keon Chae; Seung Ho Hur; Sun Ho Hwang; Jin Yong Hwang
Journal:  Yonsei Med J       Date:  2018-01       Impact factor: 2.759

  10 in total