Literature DB >> 17278807

2D/3D image fusion for accurate target localization and evaluation of a mask based stereotactic system in fractionated stereotactic radiotherapy of cranial lesions.

Jian-Yue Jin1, Samuel Ryu, Kathleen Faber, Tom Mikkelsen, Qing Chen, Shidong Li, Benjamin Movsas.   

Abstract

The purpose of this study was to evaluate the accuracy of a two-dimensional (2D) to three-dimensional (3D) image-fusion-guided target localization system and a mask based stereotactic system for fractionated stereotactic radiotherapy (FSRT) of cranial lesions. A commercial x-ray image guidance system originally developed for extracranial radiosurgery was used for FSRT of cranial lesions. The localization accuracy was quantitatively evaluated with an anthropomorphic head phantom implanted with eight small radiopaque markers (BBs) in different locations. The accuracy and its clinical reliability were also qualitatively evaluated for a total of 127 fractions in 12 patients with both kV x-ray images and MV portal films. The image-guided system was then used as a standard to evaluate the overall uncertainty and reproducibility of the head mask based stereotactic system in these patients. The phantom study demonstrated that the maximal random error of the image-guided target localization was +/-0.6 mm in each direction in terms of the 95% confidence interval (CI). The systematic error varied with measurement methods. It was approximately 0.4 mm, mainly in the longitudinal direction, for the kV x-ray method. There was a 0.5 mm systematic difference, primarily in the lateral direction, between the kV x-ray and the MV portal methods. The patient study suggested that the accuracy of the image-guided system in patients was comparable to that in the phantom. The overall uncertainty of the mask system was +/-4 mm, and the reproducibility was +/-2.9 mm in terms of 95% CI. The study demonstrated that the image guidance system provides accurate and precise target positioning.

Entities:  

Mesh:

Year:  2006        PMID: 17278807     DOI: 10.1118/1.2392605

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  23 in total

1.  Clinical results of a pilot study on stereovision-guided stereotactic radiotherapy and intensity modulated radiotherapy.

Authors:  Shidong Li; Lawrence R Kleinberg; Daniele Rigamonti; Moody D Wharam; Abdul Rashid; Juan Jackson; David Djajaputra; Shenjen He; Tunisia Creasey; Theodore L DeWeese
Journal:  Technol Cancer Res Treat       Date:  2010-12

2.  On the accuracy of isocenter verification with kV imaging in stereotactic radiosurgery.

Authors:  Rolf Wiehle; Hans-Jürgen Koth; Norbert Nanko; Anca-Ligia Grosu; Norbert Hodapp
Journal:  Strahlenther Onkol       Date:  2009-05-15       Impact factor: 3.621

3.  Accuracy of positional correction for the floor-mounted kV X-ray IGRT system in angled couch positions.

Authors:  Satoshi Koubuchi; Toru Takakura; Mitsuhiro Nakamura; Takashi Mizowaki; Manabu Nakata; Masahiro Hiraoka
Journal:  Radiol Phys Technol       Date:  2014-06-13

4.  Results of a multi-institutional benchmark test for cranial CT/MR image registration.

Authors:  Kenneth Ulin; Marcia M Urie; Joel M Cherlow
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-04-08       Impact factor: 7.038

5.  A Systematic Analysis of Errors in Target Localization and Treatment Delivery for Stereotactic Radiosurgery Using 2D/3D Image Registration.

Authors:  Hao Xu; Stephen Brown; Indrin J Chetty; Ning Wen
Journal:  Technol Cancer Res Treat       Date:  2016-08-31

6.  2D-3D radiograph to cone-beam computed tomography (CBCT) registration for C-arm image-guided robotic surgery.

Authors:  Wen Pei Liu; Yoshito Otake; Mahdi Azizian; Oliver J Wagner; Jonathan M Sorger; Mehran Armand; Russell H Taylor
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-12-12       Impact factor: 2.924

7.  The role of salvage reirradiation for malignant gliomas that progress on bevacizumab.

Authors:  Roy G Torcuator; Ravneet Thind; Mehul Patel; Y S Mohan; Joseph Anderson; Thomas Doyle; Samuel Ryu; Rajan Jain; Lonni Schultz; Mark Rosenblum; Tom Mikkelsen
Journal:  J Neurooncol       Date:  2009-10-17       Impact factor: 4.130

8.  Automatic localization of vertebral levels in x-ray fluoroscopy using 3D-2D registration: a tool to reduce wrong-site surgery.

Authors:  Y Otake; S Schafer; J W Stayman; W Zbijewski; G Kleinszig; R Graumann; A J Khanna; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2012-08-03       Impact factor: 3.609

9.  Salvage reirradiation for recurrent glioblastoma with radiosurgery: radiographic response and improved survival.

Authors:  Mehul Patel; Farzan Siddiqui; Jian-Yue Jin; Tom Mikkelsen; Mark Rosenblum; Benjamin Movsas; Samuel Ryu
Journal:  J Neurooncol       Date:  2008-12-09       Impact factor: 4.130

10.  Radiosurgery for melanoma brain metastases: the impact of hemorrhage on local control.

Authors:  Amol J Ghia; Jonathan D Tward; Christopher J Anker; Kenneth M Boucher; Randy L Jensen; Dennis C Shrieve
Journal:  J Radiosurg SBRT       Date:  2014
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.