Literature DB >> 17278797

Characterization of the susceptibility artifact around a prostate brachytherapy seed in MRI.

K Wachowicz1, S D Thomas, B G Fallone.   

Abstract

Magnetic distortions surrounding a typical brachytherapy seed (IMC6711, OncoSeed) within a clinical magnetic resonance imager were modeled for a number of different seed orientations with respect to the main magnetic field. From these distortion maps, simulated images were produced. The simulated images were then compared to images experimentally acquired using a spin echo technique on a Philips 1.5 T magnetic resonance imaging scanner. The modeled images were found to conform very well to those acquired experimentally, thus allowing one to establish where the seed is positioned within the complex image distortion patterns. The artifact patterns were dependent on the orientation of the seed with the main magnetic field, as well as the direction of the read encode gradient. While all imaging schemes which employ a unidirectional linear read encode trajectory should produce the artifacts modeled in this article, sequences other than spin echo may produce additional artifacts. Gradient echo and steady-state free precession imaging techniques were also performed on the seed for comparison.

Entities:  

Mesh:

Year:  2006        PMID: 17278797     DOI: 10.1118/1.2364052

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  9 in total

1.  Modeling of active shimming of metallic needles for interventional MRI.

Authors:  Saikat Sengupta
Journal:  Magn Reson Med       Date:  2020-06-29       Impact factor: 4.668

2.  A Study of Needle Image Artifact Localization in Confirmation Imaging of MRI-guided Robotic Prostate Biopsy.

Authors:  Sang-Eun Song; Nathan B Cho; Iulian I Iordachita; Peter Guion; Gabor Fichtinger; Louis L Whitcomb
Journal:  IEEE Int Conf Robot Autom       Date:  2011-08-15

3.  Effect of pulse sequence parameter selection on signal strength in positive-contrast MRI markers for MRI-based prostate postimplant assessment.

Authors:  Tze Yee Lim; Rajat J Kudchadker; Jihong Wang; R Jason Stafford; Christopher MacLellan; Arvind Rao; Geoffrey S Ibbott; Steven J Frank
Journal:  Med Phys       Date:  2016-07       Impact factor: 4.071

4.  Biopsy needle artifact localization in MRI-guided robotic transrectal prostate intervention.

Authors:  Sang-Eun Song; Nathan Bongjoon Cho; Iulian I Iordachita; Peter Guion; Gabor Fichtinger; Aradhana Kaushal; Kevin Camphausen; Louis L Whitcomb
Journal:  IEEE Trans Biomed Eng       Date:  2012-04-03       Impact factor: 4.538

5.  Minimal artifact actively shimmed metallic needles in MRI.

Authors:  Saikat Sengupta; Xinqiang Yan; Tamarya L Hoyt; Gary Drake; Anthony Gunderman; Yue Chen
Journal:  Magn Reson Med       Date:  2021-08-19       Impact factor: 4.668

6.  Fast Fourier-based simulation of off-resonance artifacts in steady-state gradient echo MRI applied to metal object localization.

Authors:  Frank Zijlstra; Job G Bouwman; Ieva Braškutė; Max A Viergever; Peter R Seevinck
Journal:  Magn Reson Med       Date:  2016-12-07       Impact factor: 4.668

7.  Clinical implementation, logistics and workflow guide for MRI image based interstitial HDR brachytherapy for gynecological cancers.

Authors:  Hualin Zhang; Eric D Donnelly; Jonathan B Strauss; Zhuang Kang; Mahesh Gopalakrishnan; Plato C Lee; Gocha Khelashvili; Chithra K Nair; Brian H Lee; Vythialingam Sathiaseelan
Journal:  J Appl Clin Med Phys       Date:  2019-10-10       Impact factor: 2.102

8.  Artifact reduction of coaxial needles in magnetic resonance imaging-guided abdominal interventions at 1.5 T: a phantom study.

Authors:  Vanessa Franziska Schmidt; Federica Arnone; Olaf Dietrich; Max Seidensticker; Marco Armbruster; Jens Ricke; Philipp Maximilian Kazmierczak
Journal:  Sci Rep       Date:  2021-11-25       Impact factor: 4.379

9.  Verification of needle guidance accuracy in pelvic phantom using registered ultrasound and MRI images for intracavitary/interstitial gynecologic brachytherapy.

Authors:  Zhiyong Yang; Ziqi Liu; Shan Jiang; Jing Zeng; Yuanjing Hu; Guobin Zhang
Journal:  J Contemp Brachytherapy       Date:  2020-04-30
  9 in total