Ambient illumination revisited: a new adaptation-based approach for optimizing medical imaging reading environments.

Amarpreet S Chawla1, Ehsan Samei.   

Abstract

Ambient lighting in soft-copy reading rooms is currently kept at low values to preserve contrast rendition in the dark regions of a medical image. Low illuminance levels, however, create inadequate viewing conditions and may also cause eye strain. This eye strain may be potentially attributed to notable variations in the luminance adaptation state of the reader's eyes when moving the gaze intermittently between the brighter display and darker surrounding surfaces. This paper presents a methodology to minimize this variation and optimize the lighting conditions of reading rooms by exploiting the properties of liquid crystal displays (LCDs) with low diffuse reflection coefficients and high luminance ratio. First, a computational model was developed to determine a global luminance adaptation value, Ladp, when viewing a medical image on display. The model is based on the diameter of the pupil size, which depends on the luminance of the observed object. Second, this value was compared with the luminance reflected off surrounding surfaces, Ls, under various conditions of room illuminance, E, different values of diffuse reflection coefficients of surrounding surfaces, Rs, and calibration settings of a typical LCD. The results suggest that for typical luminance settings of current LCDs, it is possible to raise ambient illumination to minimize differences in eye adaptation, potentially reducing visual fatigue while also complying with the TG18 specifications for controlled contrast rendition. Specifically, room illumination in the 75-150 lux range and surface diffuse reflection coefficients in the practical range of 0.13-0.22 sr(-1) provide an ideal setup for typical LCDs. Future LCDs with lower diffuse reflectivity and with higher inherent luminance ratios can provide further improvement of ergonomic viewing conditions in reading rooms.

Entities:  

Mesh:

Year:  2007        PMID: 17278493     DOI: 10.1118/1.2402583

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  14 in total

1.  The effects of ambient lighting in chest radiology reading rooms.

Authors:  Benjamin J Pollard; Ehsan Samei; Amarpreet S Chawla; Craig Beam; Laura E Heyneman; Lynne M Hurwitz Koweek; Santiago Martinez-Jimenez; Lacey Washington; Noriyuki Hashimoto; H Page McAdams
Journal:  J Digit Imaging       Date:  2012-08       Impact factor: 4.056

2.  Comparison of detectability of a simple object with low contrast displayed on a high-brightness color LCD and a monochrome LCD.

Authors:  Keita Takahashi; Junji Morishita; Takeshi Hiwasa; Shiro Hatanaka; Shuji Sakai; Noriyuki Hashimoto; Yasuhiko Nakamura; Fukai Toyofuku; Yoshiharu Higashida; Masafumi Ohki
Journal:  Radiol Phys Technol       Date:  2010-06-12

Review 3.  [Ergonomically designed radiology workplace].

Authors:  T Knogler; H Ringl
Journal:  Radiologe       Date:  2014-01       Impact factor: 0.635

4.  ACR-AAPM-SIIM technical standard for electronic practice of medical imaging.

Authors:  James T Norweck; J Anthony Seibert; Katherine P Andriole; David A Clunie; Bruce H Curran; Michael J Flynn; Elizabeth Krupinski; Ralph P Lieto; Donald J Peck; Tariq A Mian
Journal:  J Digit Imaging       Date:  2013-02       Impact factor: 4.056

5.  The influence of ambient lighting on the detection of small contrast elements in digital dental radiographs.

Authors:  Till Schriewer; Ralf Schulze; Andreas Filippi; Irene Mischak; Michael Payer; Dorothea Dagassan-Berndt; Sebastian Kühl
Journal:  Clin Oral Investig       Date:  2012-10-07       Impact factor: 3.573

6.  Breast screen new South wales generally demonstrates good radiologic viewing conditions.

Authors:  BaoLin Pauline Soh; Warwick Lee; Jennifer L Diffey; Mark F McEntee; Peter L Kench; Warren M Reed; Patrick C Brennan
Journal:  J Digit Imaging       Date:  2013-08       Impact factor: 4.056

7.  Effect of angular performance on the chromaticity of grayscale images displayed on medical liquid-crystal displays.

Authors:  Hiroshi Akamine; Junji Morishita; Michinobu Matsuyama; Noriyuki Hashimoto; Yasuhiko Nakamura; Hidetake Yabuuchi
Journal:  Radiol Phys Technol       Date:  2012-08-22

8.  A Feasibility Study of Smartphone-Based Telesonography for Evaluating Cardiac Dynamic Function and Diagnosing Acute Appendicitis with Control of the Image Quality of the Transmitted Videos.

Authors:  Changsun Kim; Hyunmin Cha; Bo Seung Kang; Hyuk Joong Choi; Tae Ho Lim; Jaehoon Oh
Journal:  J Digit Imaging       Date:  2016-06       Impact factor: 4.056

9.  Human contrast-detail performance with declining contrast.

Authors:  Alisa Walz-Flannigan; Ben Babcock; George C Kagadis; Jihong Wang; Steve G Langer
Journal:  Med Phys       Date:  2012-09       Impact factor: 4.071

10.  Determining optimal medical image compression: psychometric and image distortion analysis.

Authors:  Alexander C Flint
Journal:  BMC Med Imaging       Date:  2012-07-31       Impact factor: 1.930

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.