Human contrast-detail performance with declining contrast.

Alisa Walz-Flannigan1, Ben Babcock, George C Kagadis, Jihong Wang, Steve G Langer.   

Abstract

PURPOSE: How do display settings and ambient lighting affect contrast detection thresholds for human observers? Can recalibrating a display for high ambient lighting improve object detection?
METHODS: Contrast∕detail (CD) threshold detection performance was measured for observers using four color displays with varying overall contrast (e.g., differing maximum luminance and ambient lighting conditions). Detailed mapping of contrast detection performance (for fixed object size) was tracked as a function of: display maximum luminance, ambient lighting changes (with and without recalibrating for the higher ambience), and the performance of radiologists vs. nonradiologists.
RESULTS: The initial phase was analyzed with a hierarchical linear model of observer performance using: background gray level, maximum display luminance, and radiologist vs. nonradiologist. The only statistically significant finding was a maximum luminance of 100 cd∕m(2) display performing worse than a baseline peak of 400 cd∕m(2). The second phase examined ambient lighting effects on detection thresholds. Background gray level and maximum display luminance were examined coupled with ambient lighting for: baseline at 30, 435 uncorrected, and 435 lx with display recalibration for the ambient conditions. Results showed ambient correction improved sensitivity for small background digital driving level, but not at higher luminance backgrounds.
CONCLUSIONS: For CD study, nonradiologist observers can be used without loss of applicability. Contrast detection thresholds improved significantly between displays with peak luminance from 100 cd∕m(2) to 200 cd∕m(2), but improvement beyond that was not statistically significant for contrast detection thresholds in a reading room environment. Applying a calibration correction at high ambience (435 lx) improved detection tasks primarily in the darker background regions.

Entities:  

Mesh:

Year:  2012        PMID: 22957612      PMCID: PMC3895086          DOI: 10.1118/1.4742851

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  16 in total

1.  Effects of luminance and resolution on observer performance with chest radiographs.

Authors:  J M Herron; T M Bender; W L Campbell; J H Sumkin; H E Rockette; D Gur
Journal:  Radiology       Date:  2000-04       Impact factor: 11.105

2.  Proposal of a quality-index or metric for soft copy display systems: contrast sensitivity study.

Authors:  Jihong Wang; Ken Compton; Qi Peng
Journal:  J Digit Imaging       Date:  2003-09-11       Impact factor: 4.056

3.  Influence of monitor luminance change on observer performance for detection of abnormalities depicted on chest radiographs.

Authors:  Mitsuru Ikeda; Takeo Ishigaki; Kazuhiro Shimamoto; Yoshie Kodera; Shuji Koyama; Hisashi Usami; Katsuhiko Kato
Journal:  Invest Radiol       Date:  2003-01       Impact factor: 6.016

4.  An interactive method of assessing the characteristics of softcopy display using observer performance tests.

Authors:  Jihong Wang; Qi Peng
Journal:  J Digit Imaging       Date:  2002-03-19       Impact factor: 4.056

5.  Effect of monitor luminance and ambient light on observer performance in soft-copy reading of digital chest radiographs.

Authors:  Jin Mo Goo; Ja-Young Choi; Jung-Gi Im; Hyun Ju Lee; Myung Jin Chung; Daehee Han; Seong Ho Park; Jong Hyo Kim; Sang-Hee Nam
Journal:  Radiology       Date:  2004-07-23       Impact factor: 11.105

6.  Effects of monitor luminance change on observer detection performance.

Authors:  Satoshi Hidano; Mitsuru Ikeda; Takeo Ishigaki; Hisashi Usami; Kazuhiro Shimamoto; Katsuhiko Kato
Journal:  Comput Med Imaging Graph       Date:  2005-01-25       Impact factor: 4.790

7.  Assessment of display performance for medical imaging systems: executive summary of AAPM TG18 report.

Authors:  Ehsan Samei; Aldo Badano; Dev Chakraborty; Ken Compton; Craig Cornelius; Kevin Corrigan; Michael J Flynn; Bradley Hemminger; Nick Hangiandreou; Jeffrey Johnson; Donna M Moxley-Stevens; William Pavlicek; Hans Roehrig; Lois Rutz; Jeffrey Shepard; Robert A Uzenoff; Jihong Wang; Charles E Willis
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

8.  Object detectability at increased ambient lighting conditions.

Authors:  Benjamin J Pollard; Amarpreet S Chawla; David M Delong; Noriyuki Hashimoto; Ehsan Samei
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

9.  Contrast sensitivity of digital imaging display systems: contrast threshold dependency on object type and implications for monitor quality assurance and quality control in PACS.

Authors:  Jihong Wang; Jun Xu; Veera Baladandayuthapani
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

10.  ACR-AAPM-SIIM technical standard for electronic practice of medical imaging.

Authors:  James T Norweck; J Anthony Seibert; Katherine P Andriole; David A Clunie; Bruce H Curran; Michael J Flynn; Elizabeth Krupinski; Ralph P Lieto; Donald J Peck; Tariq A Mian
Journal:  J Digit Imaging       Date:  2013-02       Impact factor: 4.056

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.