Literature DB >> 17278485

Evaluating the impact of X-ray spectral shape on image quality in flat-panel CT breast imaging.

Stephen J Glick1, Samta Thacker, Xing Gong, Bob Liu.   

Abstract

In recent years, there has been an increasing interest in exploring the feasibility of dedicated computed tomography (CT) breast imaging using a flat-panel digital detector in a truncated cone-beam imaging geometry. Preliminary results are promising and it appears as if three-dimensional tomographic imaging of the breast has great potential for reducing the masking effect of superimposed parenchymal structure typically observed with conventional mammography. In this study, a mathematical framework used for determining optimal design and acquisition parameters for such a CT breast imaging system is described. The ideal observer signal-to-noise ratio (SNR) is used as a figure of merit, under the assumptions that the imaging system is linear and shift invariant. Computation of the ideal observer SNR used a parallel-cascade model to predict signal and noise propagation through the detector, as well as a realistic model of the lesion detection task in breast imaging. For all evaluations, the total mean glandular dose for a CT breast imaging study was constrained to be approximately equivalent to that of a two-view conventional mammography study. The framework presented was used to explore the effect of x-ray spectral shape across an extensive range of kVp settings, filter material types, and filter thicknesses. The results give an indication of how spectral shape can affect image quality in flat-panel CT breast imaging.

Mesh:

Year:  2007        PMID: 17278485     DOI: 10.1118/1.2388574

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  23 in total

1.  Dosimetric characterization of a dedicated breast computed tomography clinical prototype.

Authors:  Ioannis Sechopoulos; Steve Si Jia Feng; Carl J D'Orsi
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

2.  Investigation of x-ray spectra for iodinated contrast-enhanced dedicated breast CT.

Authors:  Stephen J Glick; Andrey Makeev
Journal:  J Med Imaging (Bellingham)       Date:  2017-01-26

3.  Noise power properties of a cone-beam CT system for breast cancer detection.

Authors:  Kai Yang; Alexander L C Kwan; Shih-Ying Huang; Nathan J Packard; John M Boone
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

4.  X-ray scatter correction method for dedicated breast computed tomography.

Authors:  Ioannis Sechopoulos
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

5.  Cone beam breast CT with a high pitch (75 μm), thick (500 μm) scintillator CMOS flat panel detector: visibility of simulated microcalcifications.

Authors:  Youtao Shen; Yuncheng Zhong; Chao-Jen Lai; Tianpeng Wang; Chris C Shaw
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

6.  A statistical, task-based evaluation method for three-dimensional x-ray breast imaging systems using variable-background phantoms.

Authors:  Subok Park; Robert Jennings; Haimo Liu; Aldo Badano; Kyle Myers
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

7.  Radiation doses in volume-of-interest breast computed tomography--A Monte Carlo simulation study.

Authors:  Chao-Jen Lai; Yuncheng Zhong; Ying Yi; Tianpeng Wang; Chris C Shaw
Journal:  Med Phys       Date:  2015-06       Impact factor: 4.071

8.  Monochromatic breast computed tomography with synchrotron radiation: phase-contrast and phase-retrieved image comparison and full-volume reconstruction.

Authors:  Luca Brombal; Bruno Golosio; Fulvia Arfelli; Deborah Bonazza; Adriano Contillo; Pasquale Delogu; Sandro Donato; Giovanni Mettivier; Piernicola Oliva; Luigi Rigon; Angelo Taibi; Giuliana Tromba; Fabrizio Zanconati; Renata Longo
Journal:  J Med Imaging (Bellingham)       Date:  2018-11-27

Review 9.  Breast cancer imaging: a perspective for the next decade.

Authors:  Andrew Karellas; Srinivasan Vedantham
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

10.  Varying collimation for dark-field extraction.

Authors:  Ge Wang; Wenxiang Cong; Haiou Shen; Yu Zou
Journal:  Int J Biomed Imaging       Date:  2010-02-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.